32 research outputs found

    Delivering Bad News: Crisis Communication Methods in Academic Libraries

    Get PDF
    This exploratory study analyzed the specific crisis communication methods of academic libraries. A survey was sent to library staff at Association of Research Libraries-member colleges and universities to describe if, who, when, and how they communicated bad news to their stakeholders for major, minor, and emerging crises. The findings show that respondents used multiple communication strategies, which varied based on the crisis. The data show that libraries communicated journal and database cancellations and health and safety emergencies more slowly than access issues and were more likely not to communicate those crises at all. Respondents also more frequently chose to communicate journal and database cancellations only when asked as compared to other crises. While access issues and health and safety emergencies were primarily communicated through social media and the library’s website, stakeholders received communication about journal and database cancellations primarily through targeted emails from library liaisons, face-to-face meetings with faculty, and the library’s website. These findings suggest that respondents communicated more quickly for minor crises but were more hesitant for crises that may have presented the potential for reputational harm. The varied responses between crisis types often conflicted with best practices for whether to deliver bad news, and if so, when and by whom. These findings indicate a need for academic libraries to develop comprehensive crisis communication plans which emphasize timeliness and transparency

    Effects of Peer Support Group on Rates of Suicide Attempts, Suicidal Thoughts, and Incidences of Self-Harm for Sexual-Minority High School Students

    Get PDF
    The torment sexual minority youth experience can take a psychological toll without access to a support system. The purpose of this proposal is to determine whether an after-school peer support group for sexual minority youth could decrease incidences of suicidal thoughts, attempts, and/or self-inflicted injuries

    Environmental Justice: Law, Policy & Regulation

    Get PDF
    Environmental Justice: Law, Policy, & Regulation explores theory and practice in this dynamic subject, which fuses environmental law and civil rights enforcement. From early concerns over toxic waste in minority communities, environmental justice expanded to consider the range of environmental threats facing poor, immigrant, and indigenous communities; women, children, and seniors; and other vulnerable populations. This third edition provides extensively updated materials to address environmental justice concerns today, including oil drilling in the Arctic, the Dakota Access Pipeline, drinking water contamination in Flint, and the devastation wrought by Hurricane Maria in Puerto Rico. Featuring new chapters addressing disaster justice and food justice, this new edition also expands coverage of environmental enforcement, contaminated sites, climate justice, and environmental justice in Indian country, all with an eye towards identifying modern challenges and available tools for the continuing pursuit of environmental justice.https://digitalrepository.unm.edu/law_facbookdisplay/1202/thumbnail.jp

    The Design of Student Training Resources to Enhance the Student Voice in Academic Quality Assurance and Quality Enhancement Processes

    Get PDF
    Without appropriate training and recognition, students – in particular Class Representatives – often struggle to engage fully with a University’s quality assurance and quality enhancement processes. Through the “Our Student Voice” project in Technological University Dublin (TU Dublin), a suite of digital training resources were designed to provide training for students to help develop the requisite knowledge and skills for effective participation there processes, thus strengthening student engagement and enhancing the student voice. The resources are organised into thirteen accessible episodes that each commence with an animated scenario that sets out key messages. The remainder of the episode provides detailed guidance for students and learning activities to help students develop their skillset. Upon completion of the learning activities, and having satisfactorily undertaken one of three specific student role in the quality processes, students can apply for recognition through a digital badge. The training resources and digital badges have been co-designed by a project team comprised of staff and students from across the University guided by best practice internationally. This paper describes the co-design process and presents a set of lessons learned that may assist other higher education institutions in enabling impactful student engagement in their academic quality assurance and quality enhancement processes

    Real world outcomes using 20 mm balloon expandable SAPIEN 3/ultra valves compared to larger valves (23, 26, and 29 mm)-a propensity matched analysis

    Get PDF
    OBJECTIVE/BACKGROUND: Small balloon expandable valves have higher echocardiographic transvalvular gradients and rates of prosthesis-patient mismatch (PPM) compared to larger valves. However, the impact of these echocardiographic findings on clinical outcomes is unknown. We sought to determine the clinical outcomes of 20 mm SAPIEN 3 (S3 BEV) compared to larger S3 BEV in relation to echocardiographic hemodynamics. METHODS: Using the STS/ACC transcatheter valve registry, we performed a propensity-matched comparison of patients undergoing treatment of native aortic valve stenosis using transfemoral, balloon-expandable implantation of 20 mm and ≥ 23 mm S3 BEVs. Baseline and procedure characteristics, echocardiographic variables and survival were analyzed. Multivariable logistic regression was used to identify predictors of 1-year mortality. RESULTS: After propensity matching of the 20 mm and ≥ 23 mm SAPIEN 3 valves, 3,931 pairs with comparable baseline characteristics were identified. Small valves were associated with significantly higher echocardiographic gradients at discharge (15.7 ± 7.1 mmHg vs. 11.7 ± 5.5 mmHg, p \u3c 0.0001) and severe PPM rates (21.5% vs. 9.7%, p \u3c 0.0001). There was no significant difference in 1-year all-cause mortality (20 mm: 13.0% vs. ≥23 mm: 12.7%, p = 0.72) or other major adverse event rates and outcomes between the two cohorts. Based on a multivariable analysis, elevated discharge mean gradient (\u3e20 mmHg), severe PPM and the use of 20 mm versus ≥23 mm were not independent predictors of 1-year mortality. CONCLUSION: SAPIEN 3 20 mm valves were associated with higher echocardiographic gradients, and severe PPM rates compared to larger valves but these factors were not associated with significant differences in 1-year all-cause mortality or rehospitalization

    Prospective Evaluation of TMVR for Failed Surgical Annuloplasty Rings: MITRAL Trial Valve-in-Ring Arm 1-Year Outcomes

    Get PDF
    OBJECTIVES: The authors report 1-year outcomes of high-risk patients with failed surgical annuloplasty rings undergoing transseptal mitral valve-in-ring (MViR) with the SAPIEN 3 aortic transcatheter heart valve (THV). BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective study evaluating transseptal MViR with the SAPIEN 3 aortic THV in high-risk patients with failed surgical annuloplasty rings. METHODS: Prospective enrollment of high-risk patients with symptomatic moderate to severe or severe mitral regurgitation (MR) or severe mitral stenosis and failed annuloplasty rings at 13 U.S. sites. The primary safety endpoint was technical success. The primary THV performance endpoint was absence of MR grade ≥2+ or mean mitral valve gradient ≥10 mm Hg (30 days and 1 year). Secondary endpoints included procedural success and all-cause mortality (30 days and 1 year). RESULTS: Thirty patients were enrolled between January 2016 and October 2017 (median age 71.5 years [interquartile range: 67.0 to 76.8 years], 36.7% women, median Society of Thoracic Surgeons score 7.6% [interquartile range: 5.1% to 11.8%], 76.7% in New York Heart Association functional class III or IV). Technical success was 66.7% (driven primarily by need for a second valve in 6 patients). There was no intraprocedural mortality or conversion to surgery. The primary performance endpoint was achieved in 85.7% of survivors at 30 days (24 of 28) and 89.5% of patients alive at 1 year with echocardiographic data available (17 of 19). All-cause mortality at 30 days was 6.7% and at 1 year was 23.3%. Among survivors at 1-year follow-up, 84.2% were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.0 mm Hg (interquartile range: 4.7 to 7.3 mm Hg), and all had ≤1+ MR. CONCLUSIONS: Transseptal MViR was associated with a 30-day mortality rate lower than predicted by the Society of Thoracic Surgeons score. At 1 year, transseptal MViR was associated with symptom improvement and stable THV performance

    Prospective Study of TMVR Using Balloon-Expandable Aortic Transcatheter Valves in MAC: MITRAL Trial 1-Year Outcomes

    Get PDF
    OBJECTIVES: The aim of this study was to evaluate 1-year outcomes of valve-in-mitral annular calcification (ViMAC) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating the feasibility of ViMAC using balloon-expandable aortic transcatheter heart valves. METHODS: A multicenter prospective study was conducted, enrolling high-risk surgical patients with severe mitral annular calcification and symptomatic severe mitral valve dysfunction at 13 U.S. sites. RESULTS: Between February 2015 and December 2017, 31 patients were enrolled (median age 74.5 years [interquartile range (IQR): 71.3 to 81.0 years], 71% women, median Society of Thoracic Surgeons score 6.3% [IQR: 5.0% to 8.8%], 87.1% in New York Heart Association functional class III or IV). Access was transatrial (48.4%), transseptal (48.4%), or transapical (3.2%). Technical success was 74.2%. Left ventricular outflow tract obstruction (LVOTO) with hemodynamic compromise occurred in 3 patients (transatrial, n = 1; transseptal, n = 1; transapical, n = 1). After LVOTO occurred in the first 2 patients, pre-emptive alcohol septal ablation was implemented to decrease risk in high-risk patients. No intraprocedural deaths or conversions to open heart surgery occurred during the index procedures. All-cause mortality at 30 days was 16.7% (transatrial, 21.4%; transseptal, 6.7%; transapical, 100% [n = 1]; p = 0.33) and at 1 year was 34.5% (transatrial, 38.5%; transseptal, 26.7%; p = 0.69). At 1-year follow-up, 83.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.1 mm Hg (IQR: 5.6 to 7.1 mm Hg), and all patients had ≤1+ mitral regurgitation. CONCLUSIONS: At 1 year, ViMAC was associated with symptom improvement and stable transcatheter heart valve performance. Pre-emptive alcohol septal ablation may prevent transcatheter mitral valve replacement-induced LVOTO in patients at risk. Thirty-day mortality of patients treated via transseptal access was lower than predicted by the Society of Thoracic Surgeons score. Further studies are needed to evaluate safety and efficacy of ViMAC

    Prospective Evaluation of Transseptal TMVR for Failed Surgical Bioprostheses: MITRAL Trial Valve-in-Valve Arm 1-Year Outcomes

    Get PDF
    OBJECTIVES: The aim of this study was to assess 1-year clinical outcomes among high-risk patients with failed surgical mitral bioprostheses who underwent transseptal mitral valve-in-valve (MViV) with the SAPIEN 3 aortic transcatheter heart valve (THV) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating transseptal MViV with the SAPIEN 3 aortic THV in high-risk patients with failed surgical mitral bioprostheses. METHODS: High-risk patients with symptomatic moderate to severe or severe mitral regurgitation (MR) or severe mitral stenosis due to failed surgical mitral bioprostheses were prospectively enrolled. The primary safety endpoint was technical success. The primary THV performance endpoint was absence of MR grade ≥2+ or mean mitral valve gradient ≥10 mm Hg (30 days and 1 year). Secondary endpoints included procedural success and all-cause mortality (30 days and 1 year). RESULTS: Thirty patients were enrolled between July 2016 and October 2017 (median age 77.5 years [interquartile range (IQR): 70.3 to 82.8 years], 63.3% women, median Society of Thoracic Surgeons score 9.4% [IQR: 5.8% to 12.0%], 80% in New York Heart Association functional class III or IV). The technical success rate was 100%. The primary performance endpoint in survivors was achieved in 96.6% (28 of 29) at 30 days and 82.8% (24 of 29) at 1 year. Thirty-day all-cause mortality was 3.3% and was unchanged at 1 year. The only death was due to airway obstruction after swallowing several pills simultaneously 29 days post-MViV. At 1-year follow-up, 89.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.6 mm Hg (interquartile range: 5.5 to 8.9 mm Hg), and all patients had MR grade ≤1+. CONCLUSIONS: Transseptal MViV in high-risk patients was associated with 100% technical success, low procedural complication rates, and very low mortality at 1 year. The vast majority of patients experienced significant symptom alleviation, and THV performance remained stable at 1 year

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead
    corecore