4,272 research outputs found
Optical diode based on the chirality of guided photons
Photons are nonchiral particles: their handedness can be both left and right.
However, when light is transversely confined, it can locally exhibit a
transverse spin whose orientation is fixed by the propagation direction of the
photons. Confined photons thus have chiral character. Here, we employ this to
demonstrate nonreciprocal transmission of light at the single-photon level
through a silica nanofibre in two experimental schemes. We either use an
ensemble of spin-polarised atoms that is weakly coupled to the nanofibre-guided
mode or a single spin-polarised atom strongly coupled to the nanofibre via a
whispering-gallery-mode resonator. We simultaneously achieve high optical
isolation and high forward transmission. Both are controlled by the internal
atomic state. The resulting optical diode is the first example of a new class
of nonreciprocal nanophotonic devices which exploit the chirality of confined
photons and which are, in principle, suitable for quantum information
processing and future quantum optical networks
Stabilizing nuclear spins around semiconductor electrons via the interplay of optical coherent population trapping and dynamic nuclear polarization
We experimentally demonstrate how coherent population trapping (CPT) for
donor-bound electron spins in GaAs results in autonomous feedback that prepares
stabilized states for the spin polarization of nuclei around the electrons. CPT
was realized by excitation with two lasers to a bound-exciton state.
Transmission studies of the spectral CPT feature on an ensemble of electrons
directly reveal the statistical distribution of prepared nuclear spin states.
Tuning the laser driving from blue to red detuned drives a transition from one
to two stable states. Our results have importance for ongoing research on
schemes for dynamic nuclear spin polarization, the central spin problem and
control of spin coherence.Comment: 5 pages, 4 figure
The inter-rater reliability of the diagnosis of surgical site infection in the context of a clinical trial.
ObjectivesThe diagnosis of surgical site infection following endoprosthetic reconstruction for bone tumours is frequently a subjective diagnosis. Large clinical trials use blinded Central Adjudication Committees (CACs) to minimise the variability and bias associated with assessing a clinical outcome. The aim of this study was to determine the level of inter-rater and intra-rater agreement in the diagnosis of surgical site infection in the context of a clinical trial.Materials and methodsThe Prophylactic Antibiotic Regimens in Tumour Surgery (PARITY) trial CAC adjudicated 29 non-PARITY cases of lower extremity endoprosthetic reconstruction. The CAC members classified each case according to the Centers for Disease Control (CDC) criteria for surgical site infection (superficial, deep, or organ space). Combinatorial analysis was used to calculate the smallest CAC panel size required to maximise agreement. A final meeting was held to establish a consensus.ResultsFull or near consensus was reached in 20 of the 29 cases. The Fleiss kappa value was calculated as 0.44 (95% confidence interval (CI) 0.35 to 0.53), or moderate agreement. The greatest statistical agreement was observed in the outcome of no infection, 0.61 (95% CI 0.49 to 0.72, substantial agreement). Panelists reached a full consensus in 12 of 29 cases and near consensus in five of 29 cases when CDC criteria were used (superficial, deep or organ space). A stable maximum Fleiss kappa of 0.46 (95% CI 0.50 to 0.35) at CAC sizes greater than three members was obtained.ConclusionsThere is substantial agreement among the members of the PARITY CAC regarding the presence or absence of surgical site infection. Agreement on the level of infection, however, is more challenging. Additional clinical information routinely collected by the prospective PARITY trial may improve the discriminatory capacity of the CAC in the parent study for the diagnosis of infection.Cite this article: J. Nuttall, N. Evaniew, P. Thornley, A. Griffin, B. Deheshi, T. O'Shea, J. Wunder, P. Ferguson, R. L. Randall, R. Turcotte, P. Schneider, P. McKay, M. Bhandari, M. Ghert. The inter-rater reliability of the diagnosis of surgical site infection in the context of a clinical trial. Bone Joint Res 2016;5:347-352. DOI: 10.1302/2046-3758.58.BJR-2016-0036.R1
Developmental Acquisition of Regulomes Underlies Innate Lymphoid Cell Functionality
Innate lymphoid cells (ILCs) play key roles in host defense, barrier integrity, and homeostasis and mirror adaptive CD4(+) T helper (Th) cell subtypes in both usage of effector molecules and transcription factors. To better understand the relationship between ILC subsets and their Th cell counterparts, we measured genome-wide chromatin accessibility. We find that chromatin in proximity to effector genes is selectively accessible in ILCs prior to high-level transcription upon activation. Accessibility of these regions is acquired in a stepwise manner during development and changes little after in vitro or in vivo activation. Conversely, dramatic chromatin remodeling occurs in naive CD4(+) T cells during Th cell differentiation using a type-2-infection model. This alteration results in a substantial convergence of Th2 cells toward ILC2 regulomes. Our data indicate extensive sharing of regulatory circuitry across the innate and adaptive compartments of the immune system, in spite of their divergent developing pathways
Recommended from our members
Negative Transconductance in Apertured Electron Guns
Passing an electron beam through an aperture can serve to reduce the beam current or change the transverse beam profile. For a sufficiently intense beam, space charge will drive a radial expansion of the beam, which may cause the current passing through the aperture to increase even though the current arriving at the aperture is decreasing. When a gridded electron gun is used, this may be expressed by stating that the transconductance of the apertured gun is negative. Here we explain this effect, and explore some of the key factors governing when it can occur and influencing its strength
Recommended from our members
Gridded Electron Guns and Modulation of Intense Beams
Gridded guns are useful for producing modulated electron beams. This modulation is generally limited to simple gating of the beam, but may be used to apply structure to the beam pulse shape. In intense beams, this structure spawns space charge waves whose dynamics depend in part on the relative strengths of the velocity and density variations which comprise the initial current modulation. In this paper, we calculate the strengths of beam current and velocity modulation produced in a gridded electron gun, and show that under normal conditions the initial modulation is dominated by density variation rather than velocity variation
Turbulent Mixing in the Interstellar Medium -- an application for Lagrangian Tracer Particles
We use 3-dimensional numerical simulations of self-gravitating compressible
turbulent gas in combination with Lagrangian tracer particles to investigate
the mixing process of molecular hydrogen (H2) in interstellar clouds. Tracer
particles are used to represent shock-compressed dense gas, which is associated
with H2. We deposit tracer particles in regions of density contrast in excess
of ten times the mean density. Following their trajectories and using
probability distribution functions, we find an upper limit for the mixing
timescale of H2, which is of order 0.3 Myr. This is significantly smaller than
the lifetime of molecular clouds, which demonstrates the importance of the
turbulent mixing of H2 as a preliminary stage to star formation.Comment: 10 pages, 5 figures, conference proceedings "Turbulent Mixing and
Beyond 2007
- …