77 research outputs found

    Ambulatory versus home blood pressure monitoring: frequency and determinants of blood pressure difference and diagnostic disagreement

    Get PDF
    Objectives: Out-of-office blood pressure evaluation assessed using ambulatory (ABP) or home (HBP) monitoring is currently recommended for hypertension management. We evaluated the frequency and determinants of diagnostic disagreement between ABP and HBP measurements. Methods: Cross-sectional data from 1971 participants (mean age 53.8 +/- 11.4 years, 52.6% men, 32% treated) from Greece, Finland and the United Kingdom were analyzed. The diagnostic disagreement between HBP and daytime ABP was regarded as certain when (i) the two methods diagnosed a different blood pressure phenotype, (ii) the absolute HBP-ABP difference was more than 10/5 mmHg (systolic/diastolic) and (iii) ABP and HBP had a more than 5 mmHg difference from the respective hypertension threshold. Results: In 1574 participants (79.9%), there was agreement between HBP and ABP in diagnosing hypertensive phenotypes (kappa 0.70). Of the remaining 397 participants (20.1%) with diagnostic disagreement, 95 had clinically irrelevant HBP-ABP differences, which reduced the disagreement to 15.3%. When cases with ABP and/or HBP differing <= 5 mmHg from the respective hypertension threshold were excluded, the certain disagreement between the two methods was reduced to 8.2%. Significant determinants of the HBP-ABP difference were age, sex, study center, BMI, cardiovascular disease history, office hypertension and antihypertensive treatment. Antihypertensive drug treatment, alcohol consumption and office normotension independently increased the odds of diagnostic disagreement. Conclusion: These data suggest that there is considerable diagnostic agreement between HBP and ABP, and that these methods are interchangeable for clinical decisions in most patients. However, considerable disagreement between the two methods occurs in an appreciable minority, most likely due to methodological and patient-related factors

    Opposing Age-Related Trends in Absolute and Relative Risk of Adverse Health Outcomes Associated With Out-of-Office Blood Pressure

    Get PDF
    Participant-level meta-analyses assessed the age-specific relevance of office blood pressure to cardiovascular complications, but this information is lacking for out-of-office blood pressure. At baseline, daytime ambulatory (n=12 624) or home (n=5297) blood pressure were measured in 17 921 participants (51.3% women; mean age, 54.2 years) from 17 population cohorts. Subsequently, mortality and cardiovascular events were recorded. Using multivariable Cox regression, floating absolute risk was computed across 4 age bands (80 years). Over 236 491 person-years, 3855 people died and 2942 cardiovascular events occurred. From levels as low as 110/65 mm Hg, risk log-linearly increased with higher out-of-office systolic/diastolic blood pressure. From the youngest to the oldest age group, rates expressed per 1000 person-years increased (P<0.001) from 4.4 (95% CI, 4.0-4.7) to 86.3 (76.1-96.5) for all-cause mortality and from 4.1 (3.9-4.6) to 59.8 (51.0-68.7) for cardiovascular events, whereas hazard ratios per 20-mm Hg increment in systolic out-of-office blood pressure decreased (P <= 0.0033) from 1.42 (1.19-1.69) to 1.09 (1.05-1.12) and from 1.70 (1.51-1.92) to 1.12 (1.07-1.17), respectively. These age-related trends were similar for out-of-office diastolic pressure and were generally consistent in both sexes and across ethnicities. In conclusion, adverse outcomes were directly associated with out-of-office blood pressure in adults. At young age, the absolute risk associated with out-of-office blood pressure was low, but relative risk high, whereas with advancing age relative risk decreased and absolute risk increased. These observations highlight the need of a lifecourse approach for the management of hypertension

    Association of night-time home blood pressure with night-time ambulatory blood pressure and targetorgan damage: A systematic review and meta-analysis

    No full text
    Objective: Night-time ambulatory blood pressure (nABP) is the most important aspect of the blood pressure profile in terms of prognosis. Novel low-cost home monitors allow automated night-time blood pressure monitoring (nHBP). This study reviewed the evidence on the association of nHBP with nABP and preclinical organ damage. Methods: Systematic review and meta-analysis. Results: Analysis of six studies (n = 1404) showed pooled difference between nHBP and nABP (SBP/DBP) at 1.4, 95% confidence interval (CI) 0.3, 2.6/-0.2, 95% CI -0.9, 0.6 mmHg, whereas the pooled correlation coefficient between nHBP and nABP (SBP/DBP) was r=0.70, 95% CI 0.59, 0.81/r= 0.72, 95% CI 0.67, 0.77, respectively. Two studies (n = 212) investigated the agreement between nHBP and nABP in detecting nondippers with weighted agreement 77.3% (pooled kappa 0.27, 95% CI 0.08, 0.45). Three studies (n = 954) reported on the association of left ventricular mass index with systolic nHBP and nABP (pooled correlation coefficient r=0.36, 95% CI 0.23, 0.50 and r=0.32, 95% CI 0.10, 0.54, respectively, P=NSfor comparison). Two studies (n = 950) reported on the association of urinary albumin excretion with systolic nHBP and nABP (pooled r = 0.39, 95% CI 0.21, 0.58 and r- 0.30, 95% CI 0.06, 0.55, respectively, P&lt;0.01 for comparison). Two studies (n = 350) reported on the association of common carotid intima-media thickness with systolic nHBP and nABP (pooled r=0.31, 95% CI 0.16, 0.46 and r=0.35, 95% CI 0.17, 0.53, respectively, P=NS for comparison). Conclusion: The available evidence suggests that nHBP and nABP present similar values and comparable relationship with target-organ damage. Studies on the prognostic value of nHBP are needed. Copyright © 2017 Wolters Kluwer Health, Inc. All rights reserved

    Out-of-office blood pressure and target organ damage in children and adolescents: A systematic reviewand meta-analysis

    No full text
    Objective: In children, out-of-office blood pressure (BP) assessment (especially ambulatory monitoring) is regarded as indispensable for accurate hypertension diagnosis. This article reviewed the evidence on the association between out-of-office BP measurements and preclinical organ damage indices in children. Methods: A systematic review and meta-analysis of 93 relevant articles (1974-2012) was performed. Results: Analysis of 10 studies (n = 480, pooled age 14.4 years, with hypertension 33%, renal disease 27%, type 1 diabetes 10%) revealed a significant association between systolic ambulatory BP and left ventricular mass index (LVMI), with pooled correlation coefficient r = 0.40 [95% confidence interval (CI) 0.30-0.50]. Eleven studies reported data on LVMI differences between normotensive (n = 428) and hypertensive children (n = 432), with higher values in the latter group by 6.53 g/m2.7 (95% CI 4.73-8.33). A moderate association was found between systolic ambulatory BP and carotid intima-media thickness (three studies, n = 231, age 13.3 years, pooled r = 0.32, 95% CI 0.21-0.44), as well as between diastolic ambulatory BP and urine albumin excretion (five studies, n = 355, age 13.1 years, type 1 diabetes 42%, reflux nephropathy 28%, pooled r = 0.32, 95% CI 0.05-0.58). Two studies reported on the association between home BP and LVMI, with one of them showing comparable coefficients as for ambulatory monitoring. Conclusion: The available evidence suggests a moderate but significant association between ambulatory BP and preclinical organ damage, mainly based on studies in nephropathy and/or diabetes. More data are needed in essential hypertension without nephropathy or diabetes, as well as with home measurements. Copyright © Lippincott Williams &amp; Wilkins

    Validation of the single-cuff oscillometric blood pressure monitor InBody BPBIO750 for public spaces according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard

    No full text
    Objective The aim of this study was to evaluate the accuracy of the single upper-arm cuff oscillometric blood pressure (BP) monitor InBody BPBIO750 developed for self-measurement by adults in public spaces (kiosk) according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018). Methods Subjects were recruited to fulfil the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. Results A total of 102 subjects were recruited and 85 were analyzed [mean age 56.7 ± 15.4 (SD) years, 40 men, arm circumference 32.3 ± 5.3 cm, range 22-42 cm]. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 2.2 ± 6.1/-2.2 ± 5.2 mmHg (systolic/diastolic). For criterion 2, the SD of the averaged BP differences between the test device and reference BP per subject was 5.00/4.63 mmHg (systolic/diastolic). Conclusion The InBody BPBIO750 device fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in general population and can be recommended for clinical use in adults. Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved