10 research outputs found

    Multicenter evaluation of Verigene Enteric Pathogens Nucleic Acid Test for detection of gastrointestinal pathogens

    Get PDF
    We investigated the efficiency of the Verigene Enteric Pathogens Nucleic Acid Test (Verigene EP test), which is an automated microarray-based assay system that enables rapid and simultaneous genetic detection of gastrointestinal pathogens and toxins, including those in the Campylobacter Group, Salmonella species, Shigella species, the Vibrio Group, Yersinia enterocolitica, Shiga toxin 1 and 2, norovirus GI/GII, and rotavirus A. Three clinical laboratories evaluated the Verigene EP test, using 268 stool samples for bacterial and toxin genes and 167 samples for viral genes.Culture-based reference methods were used for the detection of bacteria and toxins, while a different molecular assay was used for viral detection. The overall concordance rate between the Verigene EP test and the reference methods for the 1940 assays was 99.0%. The overall sensitivity and specificity of the Verigene EP test were 97.0% and 99.3%, respectively. Of the 19 samples with discordant results, 13 samples were false positives and six were false negatives. The Verigene EP test simultaneously detected two targets in 11 samples; overall, the test demonstrated high efficiency in detecting crucial diarrheagenic pathogens, indicating its suitability for clinical practice

    Bacillus cereus Bloodstream Infection in a Preterm Neonate Complicated by Late Meningitis

    No full text
    Central nervous system infections caused by Bacillus cereus have rarely been reported in infants. In this paper, the case of a 2-month-old low-birth-weight female who developed meningitis 45 days after resolution of a bloodstream infection (BSI) is described. The pulsed-field gel electrophoresis results revealed that the patterns of both B. cereus isolates responsible for the acute meningitis and for the prior bacteraemic episode were closely related. Although the source of the infection from within the patient was not clear, it is suggested that the B. cereus BSI developed in the neonate was complicated by acute meningitis

    Evaluation of performance of the GENECUBE assay for rapid molecular identification of Staphylococcus aureus and methicillin resistance in positive blood culture medium.

    No full text
    Rapid identification of causative agents from positive blood culture media is a prerequisite for the timely targeted treatment of patients with sepsis. The GENECUBE (TOYOBO Co., Ltd.) is a novel, fully-automated gene analyzer that can purify DNAs and amplify target DNAs. In this study, we evaluated the ability of two newly developed GENECUBE assays to directly detect the nuc and mecA genes in blood culture medium; nuc is specific to Staphylococcus aureus, and mecA indicates methicillin resistance. We examined 263 positive blood culture samples taken at three hospitals from patients suspected of having staphylococcal bacteremia. The results were then compared with those obtained using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, antimicrobial susceptibility testing (Microscan system or Dry-plate EIKEN), and sequencing analysis. The GENECUBE assays had sensitivity and specificity of 100% in detecting both S. aureus and methicillin resistance in positive blood culture. The turnaround time of the examination was evaluated for 36 positive blood culture samples. The time between the initiation of incubation and completion of the GENECUBE examination was 23 h (interquartile range: IQR 21-37 h); the time between reporting of Gram stain examination and completion of the GENECUBE examination was 52 min (IQR 48-62 min). These findings show that the GENECUBE assays significantly reduce the assay time with no loss of sensitivity or specificity

    Development of a mobile laboratory system in hydrogen fuel cell buses and evaluation of the performance for COVID-19 RT-PCR testing

    No full text
    Abstract We designed and developed two new types of hydrogen fuel cell (HFC) buses (motorcoach and minibus) with a mobile laboratory system. Feasibility studies have been performed for mobile laboratory testing, particularly for the laboratory performance of COVID-19 RT-PCR (PCR). We evaluated the driving range capability, PCR sample size capacity, turnaround time (TAT), and analytical performance for the detection of SARS-CoV-2. Saliva samples were used for the current study, and the analytical performance was compared with that of the reference PCR. The estimated driving range and sample size capacity of the HFC and HFC minibus were 432 km and 2847 samples, respectively, for the HFC motorcoach and 313 km and 1949 samples for the HFC minibus. For the TAT, the median time between sample submission and completion of PCR was 86 min for the motorcoach and 76 min for the minibus, and the median time between sample submission and electronic reporting of the result to each visitor was 182 min for the motorcoach and 194 min for the minibus. A secondary analysis of 1574 HFC mobile laboratory testing samples was conducted, and all negative samples were found to be negative by reference PCR. Furthermore, all samples were confirmed to be positive by reference PCR or other molecular examinations

    Potential Impact of Rapid Blood Culture Testing for Gram-Positive Bacteremia in Japan with the Verigene Gram-Positive Blood Culture Test

    No full text
    Background. Early detection of Gram-positive bacteremia and timely appropriate antimicrobial therapy are required for decreasing patient mortality. The purpose of our study was to evaluate the performance of the Verigene Gram-positive blood culture assay (BC-GP) in two special healthcare settings and determine the potential impact of rapid blood culture testing for Gram-positive bacteremia within the Japanese healthcare delivery system. Furthermore, the study included simulated blood cultures, which included a library of well-characterized methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) isolates reflecting different geographical regions in Japan. Methods. A total 347 BC-GP assays were performed on clinical and simulated blood cultures. BC-GP results were compared to results obtained by reference methods for genus/species identification and detection of resistance genes using molecular and MALDI-TOF MS methodologies. Results. For identification and detection of resistance genes at two clinical sites and simulated blood cultures, overall concordance of BC-GP with reference methods was 327/347 (94%). The time for identification and antimicrobial resistance detection by BC-GP was significantly shorter compared to routine testing especially at the cardiology hospital, which does not offer clinical microbiology services on weekends and holidays. Conclusion. BC-GP generated accurate identification and detection of resistance markers compared with routine laboratory methods for Gram-positive organisms in specialized clinical settings providing more rapid results than current routine testing

    Clinical evaluation of a non-purified direct molecular assay for the detection of Clostridioides difficile toxin genes in stool specimens.

    No full text
    Recently, a new rapid assay for the detection of tcdB gene of Clostridioides difficile was developed using the GENECUBE. The assay can directly detect the tcdB gene from stool samples without a purification in approximately 35 minutes with a few minutes of preparation process. We performed a prospective comparative study of the performance of the assay at eight institutions in Japan. Fresh residual stool samples (Bristol stool scale ≥5) were used and comparisons were performed with the BD MAX Cdiff assay and toxigenic cultures. For the evaluation of 383 stool samples compared with the BD MAX Cdiff assay, the sensitivity, and specificity of the two assays was 99.0% (379/383), 98.1% (52/53), 99.1% (327/330), respectively. In the comparison with toxigenic culture, the total, sensitivity, and specificity were 96.6% (370/383), 85.0% (51/60), and 98.8% (319/323), respectively. The current investigation indicated the GENECUBE Clostridioides difficile assay has equivalent performance with the BD MAX Cdiff assay for the detection of tcdB gene of C. difficile
    corecore