157 research outputs found

    New strategies of acquisition and processing of encephalographic biopotentials

    No full text
    Electroencephalography is a medical diagnosis technique. It consists in measuring the biopotentials produced by the upper layers of the brain at various standardized places on the skull.Since the biopotentials produced by the upper parts of the brain have an amplitude of about one microvolt, the measurements performed by an EEG are exposed to many risks.Moreover, since the present tendency is measure those signals over periods of several hours, or even several days, human analysis of the recording becomes extremely long and difficult. The use of signal analysis techniques for the help of paroxysm detection with clinical interest within the electroencephalogram becomes therefore almost essential. However the performance of many automatic detection algorithms becomes significantly degraded by the presence of interference: the quality of the recordings is therefore fundamental. This thesis explores the benefits that electronics and signal processing could bring to electroencephalography, aiming at improving the signal quality and semi-automating the data processing.These two aspects are interdependent because the performance of any semi-automation of the data processing depends on the quality of the acquired signal. Special attention is focused on the interaction between these two goals and attaining the optimal hardware/software pair. This thesis offers an overview of the medical electroencephalographic acquisition chain and also of its possible improvements. The conclusions of this work may be extended to some other cases of biological signal amplification such as the electrocardiogram (ECG) and the electromyogram (EMG). Moreover, such a generalization would be easier, because their signals have a wider amplitude and are therefore more resistant toward interference.Doctorat en sciences appliquéesinfo:eu-repo/semantics/nonPublishe

    Développement d’un convertisseur DC/DC en vue d’alimenter un implant cochléaire. -- - Ingénierie électronique

    No full text
    info:eu-repo/semantics/nonPublishe

    Design of a DC-coupled amplifier for biological measurements based on a Sallen-Key filter

    No full text
    info:eu-repo/semantics/publishe

    Reduction of power line interference using active electrodes and a driven-right-leg circuit in electroencephalographic recording with a minimum number of electrodes.

    No full text
    Unwanted power line interference is one of the most common problems in electroencephalographic recording. This paper examines how the use of active electrodes together with a driven-right-leg circuit can significantly improve interference reduction, even when the same electrode is used for common and reference which is attractive because it saves an electrode. General conclusions about the active electrodes and the driven-right-leg circuits were obtained thanks to a prototype that uses the same electrode for both common and reference. Measurements were performed both on a subject and on an electrical equivalent model.info:eu-repo/semantics/publishe

    Characterisation of the electrodes used in the EEG

    No full text
    info:eu-repo/semantics/publishe
    • …
    corecore