100 research outputs found

    Cochrane dementia group turns 21—older and (slightly) wiser

    Get PDF
    This invited editorial describes the achievements of the last 21 years of the Cochrane Dementia and Cognitive Improvement Group (DR Quinn is the coordinating editor of the group)

    Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) for the diagnosis of dementia within community dwelling populations

    Get PDF
    <b>Background</b><p></p> Various tools exist for initial assessment of possible dementia with no consensus on the optimal assessment method. Instruments that use collateral sources to assess change in cognitive function over time may have particular utility. The most commonly used informant dementia assessment is the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE).<p></p> A synthesis of the available data regarding IQCODE accuracy will help inform cognitive assessment strategies for clinical practice, research and policy.<p></p> <b>Objectives</b><p></p> Our primary objective was to determine the diagnostic accuracy of the informant based questionnaire IQCODE, for detection of all cause (undifferentiated) dementia in community-dwelling adults with no previous cognitive assessment. We sought to describe the accuracy of IQCODE (the index test) against a clinical diagnosis of dementia (the reference standard).<p></p> Our secondary objective was to describe the effect of heterogeneity on the summary estimates. We were particularly interested in the traditional 26-item scale versus the 16-item short form; and language of administration. We explored the effect of varying the threshold IQCODE score used to define 'test positivity'.<p></p> <b>Search methods</b><p></p> We searched the following sources on 28 January 2013: ALOIS (Cochrane Dementia and Cognitive Improvement Group), MEDLINE (OvidSP), EMBASE (OvidSP), PsycINFO (OvidSP), BIOSIS Previews (ISI Web of Knowledge), Web of Science with Conference Proceedings (ISI Web of Knowledge), LILACS (BIREME). We also searched sources relevant or specific to diagnostic test accuracy: MEDION (Universities of Maastrict and Leuven); DARE (York University); ARIF (Birmingham University). We used sensitive search terms based on MeSH terms and other controlled vocabulary.<p></p> <b>Selection criteria</b><p></p> We selected those studies performed in community settings that used (not necessarily exclusively) the IQCODE to assess for presence of dementia and, where dementia diagnosis was confirmed, with clinical assessment. Our intention with limiting the search to a 'community' setting was to include those studies closest to population level assessment. Within our predefined community inclusion criteria, there were relevant papers that fulfilled our definition of community dwelling but represented a selected population, for example stroke survivors. We included these studies but performed sensitivity analyses to assess the effects of these less representative populations on the summary results.<p></p> <b>Data collection and analysis</b><p></p> We screened all titles generated by the electronic database searches and abstracts of all potentially relevant studies were reviewed. Full papers were assessed for eligibility and data extracted by two independent assessors. For quality assessment (risk of bias and applicability) we used the QUADAS 2 tool. We included test accuracy data on the IQCODE used at predefined diagnostic thresholds. Where data allowed, we performed meta-analyses to calculate summary values of sensitivity and specificity with corresponding 95% confidence intervals (CIs). We pre-specified analyses to describe the effect of IQCODE format (traditional or short form) and language of administration for the IQCODE.<p></p> <b>Main results</b><p></p> From 16,144 citations, 71 papers described IQCODE test accuracy. We included 10 papers (11 independent datasets) representing data from 2644 individuals (n = 379 (14%) with dementia). Using IQCODE cut-offs commonly employed in clinical practice (3.3, 3.4, 3.5, 3.6) the sensitivity and specificity of IQCODE for diagnosis of dementia across the studies were generally above 75%.<p></p> Taking an IQCODE threshold of 3.3 (or closest available) the sensitivity was 0.80 (95% CI 0.75 to 0.85); specificity was 0.84 (95% CI 0.78 to 0.90); positive likelihood ratio was 5.2 (95% CI 3.7 to 7.5) and the negative likelihood ratio was 0.23 (95% CI 0.19 to 0.29).<p></p> Comparative analysis suggested no significant difference in the test accuracy of the 16 and 26-item IQCODE tests and no significant difference in test accuracy by language of administration. There was little difference in sensitivity across our predefined diagnostic cut-points.<p></p> There was substantial heterogeneity in the included studies. Sensitivity analyses removing potentially unrepresentative populations in these studies made little difference to the pooled data estimates. The majority of included papers had potential for bias, particularly around participant selection and sampling. The quality of reporting was suboptimal particularly regarding timing of assessments and descriptors of reproducibility and inter-observer variability.<p></p> <b>Authors' conclusions</b><p></p> Published data suggest that if using the IQCODE for community dwelling older adults, the 16 item IQCODE may be preferable to the traditional scale due to lesser test burden and no obvious difference in accuracy. Although IQCODE test accuracy is in a range that many would consider 'reasonable', in the context of community or population settings the use of the IQCODE alone would result in substantial misdiagnosis and false reassurance. Across the included studies there were issues with heterogeneity, several potential biases and suboptimal reporting quality

    Accessibility in astronomy for the visually impaired

    Get PDF
    Science Communication and Societ

    Evidence surveillance to keep up to date with new research

    Get PDF

    Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) for the early diagnosis of dementia across a variety of healthcare settings

    Get PDF
    This is a protocol for a Cochrane Review (Diagnostic test accuracy). The objectives are as follows: To determine the diagnostic accuracy of the informant based questionnaire IQCODE in a population free from dementia for the delayed diagnosis of dementia

    Machine learning reduced workload with minimal risk of missing studies: development and evaluation of an RCT classifier for Cochrane Reviews

    Get PDF
    BACKGROUND: To describe the development, calibration and evaluation of a machine learning classifier designed to reduce study identification workload in Cochrane for producing systematic reviews. METHODS: A machine learning classifier for retrieving RCTs was developed (the ‘Cochrane RCT Classifier’), with the algorithm trained using a dataset of title-abstract records from Embase, manually labelled by the Cochrane Crowd. The classifier was then calibrated using a further dataset of similar records manually labelled by the Clinical Hedges team, aiming for 99% recall. Finally, the recall of the calibrated classifier was evaluated using records of RCTs included in Cochrane Reviews that had abstracts of sufficient length to allow machine classification. RESULTS: The Cochrane RCT Classifier was trained using 280,620 records (20,454 of which reported RCTs). A classification threshold was set using 49,025 calibration records (1,587 of which reported RCTs) and our bootstrap validation found the classifier had recall of 0.99 (95% CI 0.98 to 0.99) and precision of 0.08 (95% CI 0.06 to 0.12) in this dataset. The final, calibrated RCT classifier correctly retrieved 43,783 (99.5%) of 44,007 RCTs included in Cochrane Reviews but missed 224 (0.5%). Older records were more likely to be missed than those more recently published. CONCLUSIONS: The Cochrane RCT Classifier can reduce manual study identification workload for Cochrane reviews, with a very low and acceptable risk of missing eligible RCTs. This classifier now forms part of the Evidence Pipeline, an integrated workflow deployed within Cochrane to help improve the efficiency of the study identification processes that support systematic review production
    • …
    corecore