9 research outputs found

    Estimated parameters.

    No full text
    <p>The estimated time constant (<i>Ο„<sub>r</sub></i>) and existence ratio (<i>h<sub>r</sub></i>) are shown as the mean of the results shown in <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone-0032352-g003" target="_blank">Fig. 3</a> (<i>R<sub>s</sub></i>, <i>dim</i>)β€Š=β€Š(3, 145). The results obtained by BzNMF + AIC and BzNMF + AICc are the same when the optimization criterion is the same.</p

    Decomposition results for the Rh6G signal sequence.

    No full text
    <p><a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone-0032352-g005" target="_blank">Figure 5</a> shows an example of the decomposition results for one signal sequence. The input matrix is the Rh6G measurement data in aqueous solution and consists of 54 signal sequences. The signal sequence is represented by a 92-dimensional vector. The rank was estimated to be 3 using the AIC. The open circles, the solid line, and the broken lines show the input signal sequence, the approximated signal sequence, and the decomposed components, respectively.</p

    Decomposition results for the simulated signal sequence.

    No full text
    <p><a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone-0032352-g001" target="_blank">Figure 1</a> shows examples of the decomposition results for one signal sequence. The input matrix is rank 2 and consists of 50 vectors (signal sequences). The signal sequence is represented by a 75-dimensional vector. The open circles, the solid line, and the broken lines show the input signal sequence, the approximated signal sequence, and the decomposed components, respectively. (a) shows the decomposition results obtained using the NMF optimized in the LSE. The rank of (a) is assumed to be 2. (b) shows the decomposition result obtained using BzNMF + AIC optimized in the LSE. The rank of (b) is estimated to be 2 using the AIC.</p

    Rank estimation results for different ranks and sample dimensions.

    No full text
    <p>The simulation rank <i>R<sub>s</sub></i> and the dimension of the signal sequence (<i>dim</i>) are set to <i>R<sub>s</sub></i>β€Š=β€Š{2, 3, 4, 5} and <i>dim</i>β€Š=β€Š{75, 145, 715, 1,430, 7,150}, respectively. The input matrix is constructed from 50 signal sequences in a set. The ranks are estimated by three sets of input matrices. The blue, yellow, green, and purple bars show the mean of estimated ranks in <i>R<sub>s</sub></i>β€Š=β€Š2, <i>R<sub>s</sub></i>β€Š=β€Š3, <i>R<sub>s</sub></i>β€Š=β€Š4, and <i>R<sub>s</sub></i>β€Š=β€Š5, respectively. The red error bars show the maximum and minimum estimated ranks.</p

    Comparison of computation times and estimated ranks.

    No full text
    <p>The computation times (CPU times) and the estimated ranks are evaluated using three sets of input matrices, similar to the case for <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone-0032352-g003" target="_blank">Fig. 3</a> (<i>dim</i>β€Š=β€Š145). Parameter <i>k</i> in CV is set to 3.</p

    Rank estimation results by AIC and AICc.

    No full text
    <p>The input matrix setting is the same as <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone-0032352-g001" target="_blank">Figure 1</a>. The experimental results are obtained from one set of input matrices (50 signal sequences). The AIC and AICc are optimized in the LSE. The solid line and the broken line show the results obtained by the AIC and the AICc, respectively.</p

    Error rates of parameters estimated by BzNMF + AIC optimized in the LSE.

    No full text
    <p>The simulation rank <i>R<sub>s</sub></i> and the dimension of signal sequence (<i>dim</i>) are set to <i>R<sub>s</sub></i>β€Š=β€Š{2, 3, 4, 5} and <i>dim</i>β€Š=β€Š{145, 715, 1,430, 7,150}, respectively. The input matrix is constructed from 50 signal sequences in a set. The parameters (existence rate and time constant) are estimated from the three sets of input matrices. The error rates of the parameters are calculated from 50Γ—3 signal sequences (error rate of existence rate) and three sets of input matrices (error rate of the time constant). The blue, yellow, green, and purple bars show the averaged error rates for <i>dim</i>β€Š=β€Š145, <i>dim</i>β€Š=β€Š715, <i>dim</i>β€Š=β€Š1,430, and <i>dim</i>β€Š=β€Š7,150, respectively.</p

    Estimated parameters of the EGFP input matrix.

    No full text
    <p>The results are evaluated using the EGFP input matrix, which consists of 44 signal sequences. The signal sequence is represented by a 101-dimensional vector. The rank of the fitting method <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone.0032352-Krichevsky1" target="_blank">[23]</a> is set to 2 based on previous biological knowledge, and the rank of the proposed method is estimated automatically using the AIC (12). In the fitting method <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone.0032352-Krichevsky1" target="_blank">[23]</a>, the time constants and the existence ratios are the mean values of 44 signal sequences.</p

    Estimated parameters for the Rh6G input matrix.

    No full text
    <p>The results are evaluated using the Rh6G input matrix, which consists of 54 signal sequences, each of which is represented by a 92-dimensional vector. The rank of the fitting method <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone.0032352-Krichevsky1" target="_blank">[23]</a> is set to 2 based on chemical knowledge, and the rank of the proposed method is automatically estimated using the AIC (12). In the fitting method <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0032352#pone.0032352-Krichevsky1" target="_blank">[23]</a>, the time constants and the existence ratios are the mean values of 54 signal sequences.</p
    corecore