65 research outputs found

    Phenotypic error threshold; additivity and epistasis in RNA evolution

    Get PDF
    BACKGROUND: The error threshold puts a limit on the amount of information maintainable in Darwinian evolution. The error threshold was first formulated in terms of genotypes. However, if a genotype-phenotype map involves redundancy ("mutational neutrality"), the error threshold should be formulated in terms of phenotypes since there is no unique fittest genotype. A previous study formulated the error threshold in terms of phenotypes, and their results showed that a rather low degree of mutational neutrality can increase the error threshold unlimitedly. RESULTS: We obtain an analytical formulation of the phenotypic error threshold by considering the "additive assumption", in which base substitutions do not influence each other (no epistasis). Our formulation shows that an increase of the error threshold due to mutational neutrality is limited. Computer simulations of RNA evolution are conducted to verify our formulation, and the results show a good agreement between the analytical prediction and the simulations. The comparison with the previous formulation illustrates that it is important for the prediction of the error threshold to consider that the number of base substitutions per replication is rather large near the error threshold. To examine the additive assumption, a detailed analysis of additivity and epistasis in RNA folding of a particular sequence is performed. The results show a high degree of epistasis in RNA folding; furthermore, the analysis also elucidates the reason of the success of the additive assumption. CONCLUSIONS: We conclude that an increase of the error threshold by mutational neutrality is limited, and that the additive assumption achieves a good prediction of the error threshold in spite of a high degree of epistasis in RNA folding because the average number of base substitutions of sequences retaining the phenotype per replication is sufficiently small to avoid of the effect of epistasis

    The effect of an external magnetic force on cell adhesion and proliferation of magnetically labeled mesenchymal stem cells

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As the strategy for tissue regeneration using mesenchymal stem cells (MSCs) for transplantation, it is necessary that MSCs be accumulated and kept in the target area. To accumulate MSCs effectively, we developed a novel technique for a magnetic targeting system with magnetically labeled MSCs and an external magnetic force. In this study, we examined the effect of an external magnetic force on magnetically labeled MSCs in terms of cell adhesion and proliferation.</p> <p>Methods</p> <p>Magnetically labeled MSCs were plated at the bottom of an insert under the influence of an external magnetic force for 1 hour. Then the inserts were turned upside down for between 1 and 24 hours, and the number of MSCs which had fallen from the membrane was counted. The gene expression of MSCs affected magnetic force was analyzed with microarray. In the control group, the same procedure was done without the external magnetic force.</p> <p>Results</p> <p>At 1 hour after the inserts were turned upside down, the average number of fallen MSCs in the magnetic group was significantly smaller than that in the control group, indicating enhanced cell adhesion. At 24 hours, the average number of fallen MSCs in the magnetic group was also significantly smaller than that in control group. In the magnetic group, integrin alpha2, alpha6, beta3 BP, intercellular adhesion molecule-2 (ICAM-2), platelet/endothelial cell adhesion molecule-1 (PECAM-1) were upregulated. At 1, 2 and 3 weeks after incubation, there was no statistical significant difference in the numbers of MSCs in the magnetic group and control group.</p> <p>Conclusions</p> <p>The results indicate that an external magnetic force for 1 hour enhances cell adhesion of MSCs. Moreover, there is no difference in cell proliferation after using an external magnetic force on magnetically labeled MSCs.</p

    Nanodiamonds as Carriers for Address Delivery of Biologically Active Substances

    Get PDF
    Surface of detonation nanodiamonds was functionalized for the covalent attachment of immunoglobulin, and simultaneously bovine serum albumin and Rabbit Anti-Mouse Antibody. The nanodiamond-IgGI125 and RAM-nanodiamond-BSAI125 complexes are stable in blood serum and the immobilized proteins retain their biological activity. It was shown that the RAM-nanodiamond-BSAI125 complex is able to bind to the target antigen immobilized on the Sepharose 6B matrix through antibody–antigen interaction. The idea can be extended to use nanodiamonds as carriers for delivery of bioactive substances (i.e., drugs) to various targets in vivo

    Blood flow changes using a 3D xenogeneic collagen matrix or a subepithelial connective tissue graft for root coverage procedures: a pilot study.

    Get PDF
    BACKGROUND: The study investigated the early healing process following the treatment of single Miller class I and II recessions with a 3D xenogeneic collagen matrix (CMX) or connective tissue graft (CTG). METHODS: This pilot investigation was designed as a single-center randomized controlled parallel trial. A total of eight subjects (four per group) were treated with either CMX or CTG in the anterior maxilla. Vascular flow changes were assessed by laser Doppler flowmetry (LDF) before and after surgery and at days 1, 2, 3, 7, 14, and 30 while clinical evaluations took place at baseline and at days 60 and 180. Pain intensity perception was evaluated by the short-form McGill pain questionnaire (SF-MPQ), at days 1 and 14. RESULTS: The vascular flow fluctuated similarly in both groups pre- and post-operatively, but the CTG exhibited a more homogeneous pattern as opposed to CMX that showed a second phase of increased blood flow at 14 days. Clinically, the CTG led to greater change in mean root coverage and keratinized tissue gain but CMX was associated with lower early pain intensity scores. CONCLUSIONS: Within the limits of the study, the vascular flow alterations during the early healing of both graft types followed a similar pattern. The CMX was associated with a second peak of increased blood flow. CLINICAL RELEVANCE: The vascular flow changes after the application of CMX for single tooth recession root coverage did not show major differences from those observed after the use of a CTG. A trend for better clinical performance in terms of root coverage and keratinized tissue gain was noted for the CTG, but the initial patient morbidity was less for CMX

    ENDOSCOPIC SPHINCTEROTOMY: MY METHOD

    No full text

    Temperature and pressure effects on the bending modulus of monolayers in a ternary microemulsion

    Get PDF
    We performed small-angle neutron scattering and neutron spin echo experiments on a ternary microemulsion composed of ionic surfactant AOT, water, and decane. Thermal fluctuations of monolayers have been investigated as a function of temperature and pressure. The amphiphilic monolayers become more flexible with increasing temperature and more rigid with increasing pressure. These results are consistent with the microscopic picture that the head-head repulsion of the AOT molecules is enhanced at high temperature while an attractive interaction between the hydrophobic tails of the AOT molecules increases at high pressure
    corecore