13 research outputs found

    C-Series Coelenterazine-Driven Bioluminescence Signature Imaging

    No full text
    The present study introduces a unique BL signature imaging system with novel CTZ analogues named “C-series.” Nine kinds of C-series CTZ analogues were first synthesized, and BL intensity patterns and spectra were then examined according to the marine luciferases. The results show that the four CTZ analogues named C3, C4, C6, and C7, individually or collectively luminesce with completely distinctive BL spectral signatures and intensity patterns according to the luciferases: Renilla luciferase (RLuc), NanoLuc, and artificial luciferase (ALuc). The signatural reporters were multiplexed into a multi-reporter system comprising RLuc8.6-535SG and ALuc16. The usefulness of the signatural reporters was further determined with a multi-probe system that consists of two single-chain probes embedding RLuc8 and ALuc23. This study is a great addition to the study of conventional bioassays with a unique methodology, and for the specification of each signal in a single- or multi-reporter system using unique BL signatures and patterns of reporter luciferases

    S-Series Coelenterazine-Driven Combinatorial Bioluminescence Imaging Systems for Mammalian Cells

    No full text
    A unique combinatorial bioluminescence (BL) imaging system was developed for determining molecular events in mammalian cells with various colors and BL intensity patterns. This imaging system consists of one or multiple reporter luciferases and a series of novel coelenterazine (CTZ) analogues named “S-series”. For this study, ten kinds of novel S-series CTZ analogues were synthesized and characterized concerning the BL intensities, spectra, colors, and specificity of various marine luciferases. The characterization revealed that the S-series CTZ analogues luminesce with blue-to-orange-colored BL spectra with marine luciferases, where the most red-shifted BL spectrum peaked at 583 nm. The colors completed a visible light color palette with those of our precedent C-series CTZ analogues. The synthesized substrates S1, S5, S6, and S7 were found to have a unique specificity with marine luciferases, such as R86SG, NanoLuc (shortly, NLuc), and ALuc16. They collectively showed unique BL intensity patterns to identify the marine luciferases together with colors. The marine luciferases, R86SG, NLuc, and ALuc16, were multiplexed into multi-reporter systems, the signals of which were quantitatively unmixed with the specific substrates. When the utility was applied to a single-chain molecular strain probe, the imaging system simultaneously reported three different optical indexes for a ligand, i.e., unique BL intensity and color patterns for identifying the reporters, together with the ligand-specific fold intensities in mammalian cells. This study directs a new combinatorial BL imaging system to specific image molecular events in mammalian cells with multiple optical indexes

    Bright Molecular Strain Probe Templates for Reporting Protein–Protein Interactions

    No full text
    Imaging protein–protein interactions (PPIs) is a hot topic in molecular medicine in the postgenomic sequencing era. In the present study, we report bright and highly sensitive single-chain molecular strain probe templates which embed full-length Renilla luciferase 8.6-535SG (RLuc86SG) or Artificial luciferase 49 (ALuc49) as reporters. These reporters were deployed between FKBP-rapamycin binding domain (FRB) and FK506-binding protein (FKBP) as a PPI model. This unique molecular design was conceptualized to exploit molecular strains of the sandwiched reporters appended by rapamycin-triggered intramolecular PPIs. The ligand-sensing properties of the templates were maximized by interface truncations and substrate modulation. The highest fold intensities, 9.4 and 16.6, of the templates were accomplished with RLuc86SG and ALuc49, respectively. The spectra of the templates, according to substrates, revealed that the colors are tunable to blue, green, and yellow. The putative substrate-binding chemistry and the working mechanisms of the probes were computationally modeled in the presence or absence of rapamycin. Considering that the molecular strain probe templates are applicable to other PPI models, the present approach would broaden the scope of the bioassay toolbox, which harnesses the privilege of luciferase reporters and the unique concept of the molecular strain probes into bioassays and molecular imaging

    How to Select Firefly Luciferin Analogues for In Vivo Imaging

    No full text
    Bioluminescence reactions are widely applied in optical in vivo imaging in the life science and medical fields. Such reactions produce light upon the oxidation of a luciferin (substrate) catalyzed by a luciferase (enzyme), and this bioluminescence enables the quantification of tumor cells and gene expression in animal models. Many researchers have developed single-color or multicolor bioluminescence systems based on artificial luciferin analogues and/or luciferase mutants, for application in vivo bioluminescence imaging (BLI). In the current review, we focus on the characteristics of firefly BLI technology and discuss the development of luciferin analogues for high-resolution in vivo BLI. In addition, we discuss the novel luciferin analogues TokeOni and seMpai, which show potential as high-sensitivity in vivo BLI reagents

    High Sensitivity In Vivo Imaging of Cancer Metastasis Using a Near-Infrared Luciferin Analogue seMpai

    No full text
    Bioluminescence imaging (BLI) is useful to monitor cell movement and gene expression in live animals. However, D-luciferin has a short wavelength (560 nm) which is absorbed by tissues and the use of near-infrared (NIR) luciferin analogues enable high sensitivity in vivo BLI. The AkaLumine-AkaLuc BLI system (Aka-BLI) can detect resolution at the single-cell level; however, it has a clear hepatic background signal. Here, to enable the highly sensitive detection of bioluminescence from the surrounding liver tissues, we focused on seMpai (C15H16N3O2S) which has been synthesized as a luciferin analogue and has high luminescent abilities as same as AkaLumine. We demonstrated that seMpai BLI could detect micro-signals near the liver without any background signal. The solution of seMpai was neutral; therefore, seMpai imaging did not cause any adverse effect in mice. seMpai enabled a highly sensitive in vivo BLI as compared to previous techniques. Our findings suggest that the development of a novel mutated luciferase against seMpai may enable a highly sensitive BLI at the single-cell level without any background signal. Novel seMpai BLI system can be used for in vivo imaging in the fields of life sciences and medicine
    corecore