    User Performance Evaluation of Four Blood Glucose Monitoring Systems Applying ISO 15197:2013 Accuracy Criteria and Calculation of Insulin Dosing Errors

    No full text
    <p></p><p><b>Article full text</b></p> <p><br></p> <p>The full text of this article can be found here<b>.</b> <a href="https://link.springer.com/article/10.1007/s13300-018-0392-6">https://link.springer.com/article/10.1007/s13300-018-0392-6</a></p><p></p><p></p><p> </p><p><br></p> <p><b>Provide enhanced content for this article</b></p> <p><br></p> <p>If you are an author of this publication and would like to provide additional enhanced content for your article then please contact <a href="http://www.medengine.com/Redeem/”mailto:[email protected]”"><b>[email protected]</b></a>.</p> <p><br></p> <p>The journal offers a range of additional features designed to increase visibility and readership. All features will be thoroughly peer reviewed to ensure the content is of the highest scientific standard and all features are marked as ‘peer reviewed’ to ensure readers are aware that the content has been reviewed to the same level as the articles they are being presented alongside. Moreover, all sponsorship and disclosure information is included to provide complete transparency and adherence to good publication practices. This ensures that however the content is reached the reader has a full understanding of its origin. No fees are charged for hosting additional open access content.</p> <p><br></p> <p>Other enhanced features include, but are not limited to:</p> <p><br></p> <p>• Slide decks</p> <p>• Videos and animations</p> <p>• Audio abstracts</p> <p>• Audio slides</p><br><p></p

    Accuracy of five systems for self-monitoring of blood glucose in the hands of adult lay-users and professionals applying ISO 15197:2013 accuracy criteria and potential insulin dosing errors

    No full text
    <p><b>Objective:</b> In this study, accuracy in the hands of intended users was evaluated for five self-monitoring of blood glucose (SMBG) systems based on ISO 15197:2013, and possibly related insulin dosing errors were calculated. In addition, accuracy was assessed in the hands of study personnel.</p> <p><b>Methods:</b> For each system (Accu-Chek<a href="#EN0001" target="_blank"><sup>1</sup></a> Aviva Connect [A], Contour<a href="#EN0002" target="_blank"><sup>2</sup></a> Next One [B], FreeStyle Freedom Lite<a href="#EN0003" target="_blank"><sup>3</sup></a> [C], GlucoMen<a href="#EN0004" target="_blank"><sup>4</sup></a> areo [D] and OneTouch Verio<a href="#EN0005" target="_blank"><sup>5</sup></a> [E]) one test strip lot was evaluated as required by ISO 15197:2013, clause 8. Number and percentage of SMBG measurements within ±15 mg/dl and ±15% of the comparison measurements at glucose concentrations <100 mg/dl and ≥100 mg/dl, respectively, were calculated. In addition, data is presented in surveillance error grids, and insulin dosing errors were modeled. The study was registered at ClinicalTrials.gov (NCT03033849).</p> <p><b>Results:</b> Four systems (A, B, C, D) fulfilled the tested reagent system lot ISO 15197:2013 accuracy criteria with the tested reagent system lot with at least 95% (lay-users) and 99.5% (study personnel) of results within the defined limits. Measurements with all five systems were within the clinically acceptable zones of the consensus error grid and the surveillance error grid. Median modeled insulin dosing errors were between -0.8 and +0.6 units for measurements performed by lay-users and between -0.7 and +0.8 units for study personnel. Frequent lay-user errors were not checking the test strips’ expiry date, applying blood incorrectly and handling the device incorrectly.</p> <p><b>Conclusion:</b> In this study, the systems showed slight differences in the number of results within ISO 15197:2013 accuracy limits. Inaccurate SMBG measurements can result in insulin dosing errors and adversely affect glycemic control.</p
    corecore