15 research outputs found

    Volatile organic compound signature from co-culture of lung epithelial cell line with Pseudomonas aeruginosa

    No full text
    Bacterial volatile organic compounds have the potential to be utilised as diagnostic biomarkers for infections.</p

    Headspace volatile organic compounds from bacteria implicated in ventilator-associated pneumonia analysed by TD-GC/MS

    No full text
    Ventilator-associated pneumonia (VAP) is a healthcare-acquired infection arising from the invasion of the lower respiratory tract by opportunistic pathogens in ventilated patients. The current method of diagnosis requires the culture of an airway sample such as bronchoalveolar lavage, which is invasive to obtain and may take up to seven days to identify a causal pathogen, or indeed rule out infection. While awaiting results, patients are administered empirical antibioticsrisks of this approach include lack of effect on the causal pathogen, contribution to the development of antibiotic resistance and downstream effects such as increased length of intensive care stay, cost, morbidity and mortality. Specific biomarkers which could identify causal pathogens in a timely manner are needed as they would allow judicious use of the most appropriate antimicrobial therapy. Volatile organic compound (VOC) analysis in exhaled breath is proposed as an alternative due to its non-invasive nature and its potential to provide rapid diagnosis at the patient\u27s bedside. VOCs in exhaled breath originate from exogenous, endogenous, as well as microbial sources. To identify potential markers, VAP-associated pathogens Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, and Staphylococcus aureus were cultured in both artificial sputum medium and nutrient broth, and their headspaces were sampled and analysed for VOCs. Previously reported volatile markers were identified in this study, including indole and 1-undecene, alongside compounds that are novel to this investigation, cyclopentanone and 1-hexanol. We further investigated media components (substrates) to identify those that are essential for indole and cyclopentanone production, with potential implications for understanding microbial metabolism in the lung

    Exhaled breath metabolomics as a noninvasive diagnostic tool for acute respiratory distress syndrome

    No full text
    There is a need for biological markers of the acute respiratory distress syndrome (ARDS). Exhaled breath contains hundreds of metabolites in the gas phase, some of which reflect (patho)physiological processes. We aimed to determine the diagnostic accuracy of metabolites in exhaled breath as biomarkers of ARDS. Breath from ventilated intensive care unit patients (n=101) was analysed using gas chromatography and mass spectrometry during the first day of admission. ARDS was defined by the Berlin definition. Training and temporal validation cohorts were used. 23 patients in the training cohort (n=53) had ARDS. Three breath metabolites, octane, acetaldehyde and 3-methylheptane, could discriminate between ARDS and controls with an area under the receiver operating characteristic curve (AUC) of 0.80. Temporal external validation (19 ARDS cases in a cohort of 48) resulted in an AUC of 0.78. Discrimination was insensitive to adjustment for severity of disease, a direct or indirect cause of ARDS, comorbidities, or ventilator settings. Combination with the lung injury prediction score increased the AUC to 0.91 and improved net reclassification by 1.17. Exhaled breath analysis showed good diagnostic accuracy for ARDS, which was externally validated. These data suggest that exhaled breath analysis could be used for the diagnostic assessment of ARD

    Levels of cytokines in broncho-alveolar lavage fluid, but not in plasma, are associated with levels of markers of lipid peroxidation in breath of ventilated ICU patients

    No full text
    Alkanes and alkenes in the breath are produced through fatty acid peroxidation, which is initialized by reactive oxygen species. Inflammation is an important cause and effect of reactive oxygen species. We aimed to evaluate the association between fatty acid peroxidation products and inflammation of the alveolar and systemic compartment in ventilated intensive care unit (ICU) patients.Volatile organic compounds were measured by gas chromatography and mass spectrometry in the breath of newly ventilated ICU patients within 24 h after ICU admission. Cytokines were measured in non-directed bronchial lavage fluid (NBL) and plasma by cytometric bead array. Correlation coefficients were calculated and presented in heatmaps.93 patients were included. Peroxidation products in exhaled breath were not associated with markers of inflammation in plasma, but were correlated with those in NBL. IL-6, IL-8, IL-1β and TNF-α concentration in NBL showed inverse correlation coefficients with the peroxidation products of fatty acids. Furthermore, NBL IL-10, IL-13, GM-CSF and IFNγ demonstrated positive associations with breath alkanes and alkenes. Correlation coefficients for NBL cytokines were high regarding peroxidation products of n-6, n-7 and particularly in n-9 fatty acids.Levels of lipid peroxidation products in the breath of ventilated ICU patients are associated with levels of inflammatory markers in NBL, but not in plasma. Alkanes and alkenes in breath seems to be associated with an anti-inflammatory, rather than a pro-inflammatory state in the alveol

    Diagnosis of acute respiratory distress syndrome (DARTS) by bedside exhaled breath octane measurements in invasively ventilated patients: protocol of a multicentre observational cohort study

    No full text
    Background: Acute respiratory distress syndrome (ARDS) is currently diagnosed by the Berlin Definition. Diagnosis is subjective and often late. Untargeted metabolomics analysis of exhaled breath with gas chromatography and mass spectrometry (GC-MS) showed that the breath concentration of octane has a high diagnostic accuracy for ARDS. To facilitate rapid bedside measurement of this biomarker, a point-of-care (POC) breath test was developed. A prototype already showed good reproducibility and repeatability for the detection of octane. In this study we aim to measure octane in exhaled breath of invasively ventilated intensive care unit (ICU) patients and validate the diagnostic accuracy of the breath test for the early diagnosis of ARDS. Methods: This is a multicentre observational cohort study in patients admitted to the ICU receiving invasive ventilation for at least 24 hours. At least 500 patients in two academic hospitals in The Netherlands will be included. ARDS patients will be compared to patients without ARDS. ARDS diagnosis will be based on the Berlin Definition. Two diagnostic assessments will be performed during the first 72 hours of invasive ventilation, including breath sampling, arterial blood gas analysis and lung ultrasound (LUS). In patients fulfilling the criteria for ARDS, three additional breath samples will be taken to assess resolution. The primary endpoint is the diagnostic accuracy for ARDS, defined by the area under the receiver operating characteristics curve (AUROCC) of octane concentration in exhaled breath. Secondary endpoints are the association between exhaled breath octane and ARDS adjusted for confounders, and the added diagnostic accuracy of the breath test on top of the Lung Injury Prediction Score (LIPS). Discussion: This is the first study that validates a metabolic biomarker of ARDS in an adequate sample size. The major novelty is the use of a POC breath test that has been specifically developed for the purpose of diagnosing ARDS. Strengths are; assessment in the early phase, in patients at risk for ARDS, longitudinal sampling and an expert panel to reliably diagnose ARDS. This study will provide a decisive answer on the question if exhaled breath metabolomics can be used to diagnose ARDS. Trial registration: The trial is registered at trialregister.nl (ID: NL8226) with the tag "DARTS"

    Development and validation of a point-of-care breath test for octane detection

    No full text
    Background: There is a demand for a non-invasive bedside method to diagnose Acute Respiratory Distress Syndrome (ARDS). Octane was discovered and validated as the most important breath biomarker for diagnosis of ARDS using gas-chromatography and mass-spectrometry (GC-MS). However, GC-MS is unsuitable as a point-of-care (POC) test in the intensive care unit (ICU). Therefore, we determined if a newly developed POC breath test can reliably detect octane in exhaled breath of invasively ventilated ICU patients. Methods: Two developmental steps were taken to design a POC breath test that relies on gas-chromatography using air as carrier gas with a photoionization detector. Calibration measurements were performed with a laboratory prototype in healthy subjects. Subsequently, invasively ventilated patients were included for validation and assessment of repeatability. After evolving to a POC breath test, this device was validated in a second group of invasively ventilated patients. Octane concentration was based on the area under the curve, which was extracted from the chromatogram and compared to known values from calibration measurements. Results: Five healthy subjects and 53 invasively ventilated patients were included. Calibration showed a linear relation (R2 = 1.0) between the octane concentration and the quantified octane peak in the low parts per billion (ppb) range. For the POC breath test the repeatability was excellent (R2 = 0.98, ICC = 0.97 (95% CI 0.94-0.99)). Conclusion: This is the first study to show that a POC breath test can rapidly and reliably detect octane, with excellent repeatability, at clinically relevant levels of low ppb in exhaled breath of ventilated ICU patients. This opens possibilities for targeted exhaled breath analysis to be used as a bedside test and makes it a potential diagnostic tool for the early detection of ARDS

    Development and validation of a point-of-care breath test for octane detection

    No full text
    Background: There is a demand for a non-invasive bedside method to diagnose Acute Respiratory Distress Syndrome (ARDS). Octane was discovered and validated as the most important breath biomarker for diagnosis of ARDS using gas-chromatography and mass-spectrometry (GC-MS). However, GC-MS is unsuitable as a point-of-care (POC) test in the intensive care unit (ICU). Therefore, we determined if a newly developed POC breath test can reliably detect octane in exhaled breath of invasively ventilated ICU patients. Methods: Two developmental steps were taken to design a POC breath test that relies on gas-chromatography using air as carrier gas with a photoionization detector. Calibration measurements were performed with a laboratory prototype in healthy subjects. Subsequently, invasively ventilated patients were included for validation and assessment of repeatability. After evolving to a POC breath test, this device was validated in a second group of invasively ventilated patients. Octane concentration was based on the area under the curve, which was extracted from the chromatogram and compared to known values from calibration measurements. Results: Five healthy subjects and 53 invasively ventilated patients were included. Calibration showed a linear relation (R2 = 1.0) between the octane concentration and the quantified octane peak in the low parts per billion (ppb) range. For the POC breath test the repeatability was excellent (R2 = 0.98, ICC = 0.97 (95% CI 0.94–0.99)). Conclusion: This is the first study to show that a POC breath test can rapidly and reliably detect octane, with excellent repeatability, at clinically relevant levels of low ppb in exhaled breath of ventilated ICU patients. This opens possibilities for targeted exhaled breath analysis to be used as a bedside test and makes it a potential diagnostic tool for the early detection of ARDS

    Development and validation of a point-of-care breath test for octane detection

    No full text
    Background: There is a demand for a non-invasive bedside method to diagnose Acute Respiratory Distress Syndrome (ARDS). Octane was discovered and validated as the most important breath biomarker for diagnosis of ARDS using gas-chromatography and mass-spectrometry (GC-MS). However, GC-MS is unsuitable as a point-of-care (POC) test in the intensive care unit (ICU). Therefore, we determined if a newly developed POC breath test can reliably detect octane in exhaled breath of invasively ventilated ICU patients. Methods: Two developmental steps were taken to design a POC breath test that relies on gas-chromatography using air as carrier gas with a photoionization detector. Calibration measurements were performed with a laboratory prototype in healthy subjects. Subsequently, invasively ventilated patients were included for validation and assessment of repeatability. After evolving to a POC breath test, this device was validated in a second group of invasively ventilated patients. Octane concentration was based on the area under the curve, which was extracted from the chromatogram and compared to known values from calibration measurements. Results: Five healthy subjects and 53 invasively ventilated patients were included. Calibration showed a linear relation (R2 = 1.0) between the octane concentration and the quantified octane peak in the low parts per billion (ppb) range. For the POC breath test the repeatability was excellent (R2 = 0.98, ICC = 0.97 (95% CI 0.94-0.99)). Conclusion: This is the first study to show that a POC breath test can rapidly and reliably detect octane, with excellent repeatability, at clinically relevant levels of low ppb in exhaled breath of ventilated ICU patients. This opens possibilities for targeted exhaled breath analysis to be used as a bedside test and makes it a potential diagnostic tool for the early detection of ARDS
    corecore