    The consistency between planned and actually given nursing care in long-terminstitutional care

    Get PDF
    Continuous information exchange between healthcare professionals is facilitated by individualized care plans. Compliance with the planned care as documented in care plans is important to provide person-centered care which contributes to the continuity of care and quality of care outcomes. Using the Nursing Interventions Classification, this study examined the consistency between documented and actually provided interventions by type of nursing staff with 150 residents in long-term institutional care. The consistency was especially high for basic (93%) and complex (79%) physiological care. To a lesser extent for interventions in the behavioral domain (66%). Except for the safety domain, the probability that documented interventions were provided was high for all domains (≥ 91%, p > 0.05). NAs generally provided the interventions as documented. Findings suggest that HCAs worked beyond there scope of practice. The results may have implications for the deployment of nursing staff and are of importance to managers

    D-Catch instrument:development and psychometric testing of a measurement instrument for nursing documentation in hospitals

    No full text
    AIM: This paper is a report of the development and testing of the psychometric properties of an instrument to measure the accuracy of nursing documentation in general hospitals. BACKGROUND: Little information is available about the accuracy of nursing documentation. None of the existing instruments that quantify accuracy of nursing diagnoses, interventions, and progress and outcome evaluations are suitable to measure documentation in general hospital environments, nor were they intended for this purpose. METHOD: The D-Catch instrument, based on the Cat-ch-Ing instrument and the Scale for Degrees of Accuracy in Nursing Diagnoses, was developed in 2007-2008. Content validity of the D-Catch instrument was assessed by two Delphi panels, in which pairs of independent reviewers assessed 245 patient records in seven hospitals in the Netherlands. Construct validity was assessed by explorative factor analysis with principal components and varimax rotation. Internal consistency was measured by Cronbach's alpha. The inter-rater reliability of the D-Catch instrument was tested by calculating Cohen's weighted kappa (K(w)) for each pair of reviewers. Results. Quantity and quality variables were used to assess the accuracy of nursing documentation. Three constructs were identified in the factor analysis. 'Accuracy of the nursing diagnosis' was the only variable with substantial loading on component two (0.907) and a modest loading on component one (0.230). Internal consistency (Cronbach's alpha) was 0.722. The inter-rater reliability (K(w)) varied between 0.742 and 0.896. CONCLUSION: The D-Catch instrument is a valid and reliable measurement instrument to assess nursing documentation in general hospital settings

    Examining Time Use of Dutch Nursing Staff in Long-Term Institutional Care:A Time-Motion Study

    No full text
    Objectives: Increasing residents' acuity levels and available resources in long-term institutional care requires insight into the care provided by nursing staff so as to guide task allocation and optimal use of resources, and enhance quality of care. The purpose of this study was to examine the relationship between time use and type of nursing staff, residents' acuity levels, and unit type by using a standardized nursing intervention classification. Design: A multicenter cross-sectional observational study was performed using time-motion technique. Setting: Five Dutch long-term institutional care facilities participated. In total, 4 residential care units, 3 somatic units, and 6 psycho-geriatric units were included. Participants: Data were collected from 136 nursing staff members: 19 registered nurses, 89 nursing assistants, 9 primary caregivers, and 19 health care assistants. Measurements: A structured observation list was used based on the Nursing Interventions Classification (NIC). Residents' acuity levels, representing residents' needs, were based on the Dutch Care Severity Index. Medians and interquartile ranges were calculated for time spent on interventions per type of nursing staff and units. Linear mixed models were used to examine the relationship between time spent on nursing interventions and the type of nursing staff, residents' acuity levels, and unit type. Results: Observations resulted in 52,628 registered minutes for 102 nursing interventions categorized into 6 NIC domains for 335 residents. Nursing staff spent the most time on direct care interventions, particularly in the domain of basic physiological care. Variances in time spent on interventions between types of nursing staff were minimal. Unit type was more significantly (P <.05) associated with time spent on interventions in domains than the type of nursing staff. Residents' acuity levels did not affect time spent by nursing staff (P > .05). Conclusion: The current study found limited evidence for task allocation between the types of nursing staff, which may suggest a blurring of role differentiation. Also, findings suggest that residents received similar care regardless of their needs, implying that care is predominantly task-oriented instead of person-centered. Managers may reconsider whether the needs of residents are adequately met by qualified nursing staff, considering the differences in education and taking into account increasing acuity levels of residents and available resources. (C) 2016 AMDA - The Society for Post-Acute and Long-Term Care Medicine
    corecore