    Numerical Study on Fluid-Structure Interaction in a Patient-Specific Abdominal Aortic Aneurysm for Evaluating Wall Heterogeneity and Material Model Effects on its Rupture

    Get PDF
    Abdominal Aortic Aneurysm (AAA) is one of the main cardiovascular diseases, which threats human’s health while it appears, develops and in crucial cases ruptures and leads to hemorrhage. In the current work, we aim to investigate numerically the transient blood flow in a patient-specific AAA model, while effects of wall compliance is considered by employing the fluid-structure interaction method. The AAA model is reconstructed from acquired CT angiographic data of a patient diagnosed with AAA and an intraluminal thrombus (ILT). For the comparison purposes two different material models, i.e. isotropic and anisotropic are considered. Additionally, to have a better estimation, wall thickness variability is compared with simpler uniform wall thickness model. In this study Navier-Stokes equations along with elastodynamics equation are coupled through Arbitrary Lagrangian-Eulerian formulation method and solved numerically. Findings demonstrate that the isotropic material model with uniform wall thickness significantly underestimates wall stresses as compared to the anisotropic material model with variable wall thickness. Indeed, results emphasize that considering vessel wall as an anisotropic, heterogeneous (variable thickness) structure estimates much higher wall stresses comparing with isotropic, uniform thickness model. Therefore, given realistic vessel wall structure and the fact that the anisotropic, variable wall thickness model predicts higher wall stresses, it could be a more reliable model to give an accurate estimation to physicians to diagnose the stage of a disease and choosing an appropriate therapeutic procedure

    Experimental and numerical study of elasto-inertial focusing in straight channels.

    Full text link
    Elasto-inertial microfluidics has drawn significant attention in recent years due to its enhanced capabilities compared to pure inertial systems in control of small microparticles. Previous investigations have focused mainly on the applications of elasto-inertial sorting, rather than studying its fundamentals. This is because of the complexity of simulation and analysis, due to the presence of viscoelastic force. There have been some investigative efforts on the mechanisms of elasto-inertial focusing in straight channels; however, these studies were limited to simple rectangular channels and neglected the effects of geometry and flow rates on focusing positions. Herein, for the first time, we experimentally and numerically explore the effects of elasticity accompanying channel cross-sectional geometry and sample flow rates on the focusing phenomenon in elasto-inertial systems. The results reveal that increasing the aspect ratio weakens the elastic force more than inertial force, causing a transition from one focusing position to two. In addition, they show that increasing the angle of a channel corner causes the elastic force to push the particles more efficiently toward the center over a larger area of the channel cross section. Following on from this, we proposed a new complex straight channel which demonstrates a tighter focusing band compared to other channel geometries. Finally, we focused Saccharomyces cerevisiae cells (3-5 μm) in the complex channel to showcase its capability in focusing small-size particles. We believe that this research work improves the understanding of focusing mechanisms in viscoelastic solutions and provides useful insights into the design of elasto-inertial microfluidic devices

    Fabrication of unconventional inertial microfluidic channels using wax 3D printing.

    Full text link
    Inertial microfluidics has emerged over the past decade as a powerful tool to accurately control cells and microparticles for diverse biological and medical applications. Many approaches have been proposed to date in order to increase the efficiency and accuracy of inertial microfluidic systems. However, the effects of channel cross-section and solution properties (Newtonian or non-Newtonian) have not been fully explored, primarily due to limitations in current microfabrication methods. In this study, we overcome many of these limitations using wax 3D printing technology and soft lithography through a novel workflow, which eliminates the need for the use of silicon lithography and polydimethylsiloxane (PDMS) bonding. We have shown that by adding dummy structures to reinforce the main channels, optimizing the gap between the dummy and main structures, and dissolving the support wax on a PDMS slab to minimize the additional handling steps, one can make various non-conventional microchannels. These substantially improve upon previous wax printed microfluidic devices where the working area falls into the realm of macrofluidics rather than microfluidics. Results revealed a surface roughness of 1.75 μm for the printed channels, which does not affect the performance of inertial microfluidic devices used in this study. Channels with complex cross-sections were fabricated and then analyzed to investigate the effects of viscoelasticity and superposition on the lateral migration of the particles. Finally, as a proof of concept, microcarriers were separated from human mesenchymal stem cells using an optimized channel with maximum cell-holding capacity, demonstrating the suitability of these microchannels in the bioprocessing industry

    Numerical and Experimental Study of Cross-Sectional Effects on the Mixing Performance of the Spiral Microfluidics.

    Full text link
    Mixing at the microscale is of great importance for various applications ranging from biological and chemical synthesis to drug delivery. Among the numerous types of micromixers that have been developed, planar passive spiral micromixers have gained considerable interest due to their ease of fabrication and integration into complex miniaturized systems. However, less attention has been paid to non-planar spiral micromixers with various cross-sections and the effects of these cross-sections on the total performance of the micromixer. Here, mixing performance in a spiral micromixer with different channel cross-sections is evaluated experimentally and numerically in the Re range of 0.001 to 50. The accuracy of the 3D-finite element model was first verified at different flow rates by tracking the mixing index across the loops, which were directly proportional to the spiral radius and were hence also proportional to the Dean flow. It is shown that higher flow rates induce stronger vortices compared to lower flow rates; thus, fewer loops are required for efficient mixing. The numerical study revealed that a large-angle outward trapezoidal cross-section provides the highest mixing performance, reaching efficiencies of up to 95%. Moreover, the velocity/vorticity along the channel length was analyzed and discussed to evaluate channel mixing performance. A relatively low pressure drop (<130 kPa) makes these passive spiral micromixers ideal candidates for various lab-on-chip applications

    Objective assessment of bradykinesia in Parkinson’s disease using evolutionary algorithms: clinical validation

    Get PDF
    Background: There is an urgent need for developing objective, effective and convenient measurements to help clinicians accurately identify bradykinesia. The purpose of this study is to evaluate the accuracy of an objective approach assessing bradykinesia in finger tapping (FT) that uses evolutionary algorithms (EAs) and explore whether it can be used to identify early stage Parkinson’s disease (PD). Methods: One hundred and seven PD, 41 essential tremor (ET) patients and 49 normal controls (NC) were recruited. Participants performed a standard FT task with two electromagnetic tracking sensors attached to the thumb and index finger. Readings from the sensors were transmitted to a tablet computer and subsequently analyzed by using EAs. The output from the device (referred to as "PD-Monitor") scaled from − 1 to +1 (where higher scores indicate greater severity of bradykinesia). Meanwhile, the bradykinesia was rated clinically using the Movement Disorder Society- Sponsored Revision of the Unified Parkinson’s Disease Rating Scale (MDS-UPDRS) FT item. Results: With an increasing MDS-UPDRS FT score, the PD-Monitor score from the same hand side increased correspondingly. PD-Monitor score correlated well with MDS-UPDRS FT score (right side: r = 0.819, P = 0.000; left side: r = 0.783, P = 0.000). Moreover, PD-Monitor scores in 97 PD patients with MDS-UPDRS FT bradykinesia and each PD subgroup (FT bradykinesia scored from 1 to 3) were all higher than that in NC. Receiver operating characteristic (ROC) curves revealed that PD-Monitor FT scores could detect different severity of bradykinesia with high accuracy (≥89.7%) in the right dominant hand. Furthermore, PD-Monitor scores could discriminate early stage PD from NC, with area under the ROC curve greater than or equal to 0.899. Additionally, ET without bradykinesia could be differentiated from PD by PD-Monitor scores. A positive correlation of PD-Monitor scores with modified Hoehn and Yahr stage was found in the left hand sides. Conclusions: Our study demonstrated that a simple to use device employing classifiers derived from EAs could not only be used to accurately measure different severity of bradykinesia in PD, but also had the potential to differentiate early stage PD from normality

    Comparative Study of Laminar Convective Heat Transfer and Pressure Drop of Nanofluids through Curved Geometries

    No full text
    In this paper, numerical simulation of flow and heat transfer of Al2O3/water nanofluid has been carried out through three different geometries involving a straight pipe, a 90o curved pipe and a 180o curved pipe under constant heat flux&nbsp;condition. Employing singe-phase model for the nanofluid, the Navier-Stokes and energy equations for an incompressible and laminar flow have been solved in a body fitted coordinate system using a homemade code based on control-volume approach, while all thermophysical properties of the nanofluid are dependent on considered temperature. The effects of different nanoparticle concentration and centrifugal forces on the temperature and pressure field have been examined in detail. The accordance of numerical results with experimental data expresses the accuracy of the&nbsp; employed numerical method for simulating flow and heat transfer in the curved pipes, as well as the accuracy of the single-phase model of the nanofluid. The Presented results indicated that both the nanoparticle and curvature effects improve the heat transfer characteristics dramatically, but at the expense of considerable increase in pressure drop. Furthermore, the results showed that in order to obtain the optimum operating conditions of nanofluids, different parameters such as heat transfer enhancement and pressure drop must be considered simultaneously. Finally, a method has been proposed to indicate the proper nanofluid and flow geometry for special practical applications

    Wood surface treatment techniques for enhanced solar steam generation

    No full text
    © 2019 Elsevier Ltd Water vapor is vital both as an energy carrier and as an intermediary state for removing impurities from water. In nature, transpiration occurs when water is transported (against gravity) from the roots to the underside of leaves where it evaporates. Using this process, one large tree can pump and purify 400 L of water each day. Based on trunk cross-sectional area, this corresponds to a water flux range of ∼100–1000 kg/m2day, but based on evaporation area it only corresponds to a rate of ∼0.1 kg/m2day. Compared to industrial mechanisms of producing water vapor (i.e. typical thermal-driven systems have a flux of ∼4000 kg/m2day), natural wood has a relatively low flux. In an effort to boost the flux of sustainable, natural wood, we investigated wood surface modifications, laser carbonization and deposition of gold nanolayers, which achieved an instantaneous evaporation rate of ∼4 kg/m2h—under 3 kW/m2 light intensity, exceeding all previous studies of synthetic materials (including 3.8 kg/m2h reported by Zhou et al. in a 2016 Nature Photonics article) for solar steam generation applications. The cost analysis of different natural and synthetic material-based techniques for solar steam generation indicated that the carbonization and laser treatments are very cost-effective and even the gold coating was comparable to previously reported synthetic materials. Based on these results, we suggest that natural, surface-modified poplar wood could represent a viable alternative to synthetic materials for liquid/vapor separation
    corecore