21,916 research outputs found

    The Decay Lifetime of Polarized Fermions in Flight

    Get PDF
    Based on the parity violation in Standard model, we study the dependence of lifetime on the helicity of an initial-state fermion in weak interactions. It is pointed out that if the initial fermions in the decays are longitudinally polarized, then the decay lifetime of left-handed polarized fermions is different from that of right-handed polarized fermions in flight with a same velocity in a same inertial system.Comment: 7 pages, Late

    Scattering by a contact potential in three and lower dimensions

    Get PDF
    We consider the scattering of nonrelativistic particles in three dimensions by a contact potential Ω2δ(r)/2μrα\Omega\hbar^2\delta(r)/ 2\mu r^\alpha which is defined as the a0a\to 0 limit of Ω2δ(ra)/2μrα\Omega\hbar^2\delta(r-a)/2\mu r^\alpha. It is surprising that it gives a nonvanishing cross section when α=1\alpha=1 and Ω=1\Omega=-1. When the contact potential is approached by a spherical square well potential instead of the above spherical shell one, one obtains basically the same result except that the parameter Ω\Omega that gives a nonvanishing cross section is different. Similar problems in two and one dimensions are studied and results of the same nature are obtained.Comment: REVTeX, 9 pages, no figur

    Electron-positron pair creation in a vacuum by an electromagnetic field in 3+1 and lower dimensions

    Get PDF
    We calculate the probability of electron-positron pair creation in vacuum in 3+1 dimensions by an external electromagnetic field composed of a constant uniform electric field and a constant uniform magnetic field, both of arbitrary magnitudes and directions. The same problem is also studied in 2+1 and 1+1 dimensions in appropriate external fields and similar results are obtained.Comment: REVTeX, 10 pages, no figure, a brief note and some more references added in the proo

    Antiparticle in Light of Einstein-Podolsky-Rosen Paradox and Klein Paradox

    Full text link
    The original version of Einstein-Podolsky-Rosen (EPR) paradox and the Klein paradox of Klein-Gordon (KG) equation are discussed to show the necessity of existence of antiparticle with its wavefunction being fixed unambiguously. No concept of "hole" is needed.Comment: 4 pages, 0 figures. Accepted by Chinese Phys. Let

    λϕ4\lambda\phi^4 model and Higgs mass in standard model calculated by Gaussian effective potential approach with a new regularization-renormalization method

    Full text link
    Basing on new regularization-renormalization method, the λϕ4\lambda\phi^4 model used in standard model is studied both perturbatively and nonperturbatively (by Gaussian effective potential). The invariant property of two mass scales is stressed and the existence of a (Landau) pole is emphasized. Then after coupling with the SU(2)×\timesU(1) gauge fields, the Higgs mass in standard model (SM) can be calculated as mHm_H\approx138GeV. The critical temperature (TcT_c) for restoration of symmetry of Higgs field, the critical energy scale (μc\mu_c, the maximum energy scale under which the lower excitation sector of the GEP is valid) and the maximum energy scale (μmax\mu_{max}, at which the symmetry of the Higgs field is restored) in the standard model are TcT_c\approx476 GeV, μc0.547×1015\mu_c\approx 0.547\times 10^{15}GeV and μmax0.873×1015\mu_{\max}\approx 0.873 \times 10^{15} GeVv respectively.Comment: 12 pages, LaTex, no figur

    Ellipsometry noise spectrum, suspension transfer function measurement and closed-loop control of the suspension system in the Q & A experiment

    Full text link
    The Q & A experiment, aiming at the detection of vacuum birefringence predicted by quantum electrodynamics, consists mainly of a suspended 3.5 m Fabry-Perot cavity, a rotating permanent dipole magnet and an ellipsometer. The 2.3 T magnet can rotate up to 10 rev/s, introducing an ellipticity signal at twice the rotation frequency. The X-pendulum gives a good isolation ratio for seismic noise above its main resonant frequency 0.3 Hz. At present, the ellipsometry noise decreases with frequency, from 1*10^{-5} rad Hz^{-1/2} at 5 Hz, 2*10^{-6} rad Hz^{-1/2} at 20 Hz to 5*10^{-7} rad Hz^{-1/2} at 40 Hz. The shape of the noise spectrum indicates possible improvement can be made by further reducing the movement between the cavity mirrors. From the preliminary result of yaw motion alignment control, it can be seen that some peaks due to yaw motion of the cavity mirror was suppressed. In this paper, we first give a schematic view of the Q & A experiment, and then present the measurement of transfer function of the compound X-pendulum-double pendulum suspension. A closed-loop control was carried out to verify the validity of the measured transfer functions. The ellipsometry noise spectra with and without yaw alignment control and the newest improvement is presented.Comment: 7 pages, 5 figures, presented in 6th Edoardo Amaldi Conference on Gravitational Waves, June 2005, Okinawa Japan and submitted to Journal of Physics: Conference Series. Some modifications are made according to the referee's comments: mainly to explain the relation between the displacement of cavity mirror and the ellipticity noise spectru
    corecore