9 research outputs found

    Implementation of a novel continuous fetal Doppler (Moyo) improves quality of intrapartum fetal heart rate monitoring in a resource-limited tertiary hospital in Tanzania: An observational study

    Get PDF
    Background Intrapartum Fetal Heart Rate (FHR) monitoring is crucial for the early detection of abnormal FHR, facilitating timely obstetric interventions and thus the potential reduction of adverse perinatal outcomes. We explored midwifery practices of intrapartum FHR monitoring pre and post implementation of a novel continuous automatic Doppler device (the Moyo). Methodology A pre/post observational study among low-risk pregnancies at a tertiary hospital was conducted from March to December 2016. In the pre-implementation period, intermittent monitoring was conducted with a Pinard stethoscope (March to June 2016, n = 1640 women). In the post-implementation period, Moyo was used for continuous FHR monitoring (July-December 2016, n = 2442 women). The primary outcome was detection of abnormal FHR defined as absent, FHR160bpm. The secondary outcomes were rates of assessment/documentation of FHR, obstetric time intervals and intrauterine resuscitations. Chi-square test, Fishers exact test, t-test and Mann-Whitney U test were used in bivariate analysis whereas binary and multinomial logistic regression were used for multivariate. Results Moyo use was associated with greater detection of abnormal FHR (8.0%) compared with Pinard (1.6%) (p Conclusion Implementation of the Moyo device, which continuously measures FHR, was associated with improved quality in FHR monitoring practices and the detection of abnormal FHR. These improvements led to more frequent and timely obstetric responses. Follow-up studies in a high-risk population focused on a more targeted description of the FHR abnormalities and the impact of intrauterine resuscitation is a critical next step in determining the effect on reducing perinatal mortality

    Women's Preferences Regarding Infant or Maternal Antiretroviral Prophylaxis for Prevention of Mother-To-Child Transmission of HIV during Breastfeeding and Their Views on Option B+ in Dar es Salaam, Tanzania.

    Get PDF
    The WHO 2010 guidelines for prevention of mother-to-child transmission (PMTCT) of HIV recommended prophylactic antiretroviral treatment (ART) either for infants (Option A) or mothers (Option B) during breastfeeding for pregnant women with a CD4 count of >350 cell/µL in low-income countries. In 2012, WHO proposed that all HIV-infected pregnant women should receive triple ART for life (B+) irrespective of CD4 count. Tanzania has recently switched from Option A to B+, with a few centers practicing B. However, more information on the real-life feasibility of these options is needed. This qualitative study explored women's preferences for Option A vs B and their views on Option B+ in Dar es Salaam, Tanzania. We conducted four focus group discussions with a total of 27 pregnant women with unknown HIV status, attending reproductive and child health clinics, and 31 in-depth interviews among HIV-infected pregnant and post-delivery women, 17 of whom were also asked about B+. Most participants were in favor of Option B compared to A. The main reasons for choosing Option B were: HIV-associated stigma, fear of drug side-effects on infants and difficult logistics for postnatal drug adherence. Some of the women asked about B+ favored it as they agreed that they would eventually need ART for their own survival. Some were against B+ anticipating loss of motivation after protecting the child, fearing drug side-effects and not feeling ready to embark on lifelong medication. Some were undecided. Option B was preferred. Since Tanzania has recently adopted Option B+, women with CD4 counts of >350 cell/µL should be counseled about the possibility to "opt-out" from ART after cessation of breastfeeding. Drug safety and benefits, economic concerns and available resources for laboratory monitoring and evaluation should be addressed during B+ implementation to enhance long-term feasibility and effectiveness

    Quality of life among cervical cancer patients following completion of chemoradiotherapy at Ocean Road Cancer Institute (ORCI) in Tanzania

    No full text
    Objective Effective cancer treatment involves aggressive chemo-radiotherapy protocols that alter survivors’ quality of life (QOL). This has recently aroused the attention not only to focus on clinical care but rather to be holistic and client-centered, looking beyond morbidity and mortality. The study assessed the QOL and associated factors among patients with cervical cancer (CC) after the completion of chemoradiotherapy. Methods A cross-sectional analytical study was conducted at Ocean Road Cancer Institute (ORCI) from September to November 2020. A total of 323 CC patients were interviewed with a structured questionnaire of QOL, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30), and its cervical cancer module (EORTC QLQ-CX24). The QOL domains, socio-demographic and clinical variables were analyzed with Mann–Whitney and Kruskal–Wallis on SPSS version 23, and a P \u3c 0.05 was considered significant. Results More than half (54.8%) of the CC patients had a good overall QOL. Overall, QOL was affected by education (P = 0.019), smoking (0.044), sexual partner (P = 0.000), treatment modality (P = 0.018), and time since completion of treatment (P = 0.021). Patients who underwent external beam radiation suffered from significant side effect symptoms (P \u3c 0.05) while those who underwent combined external beam radiation and brachytherapy had higher functioning in most domains (P \u3c 0.05). Conclusions A significant improvement in QOL was observed after chemoradiotherapy and was affected by socio-demographic and clinical variables. Thus, calls for individualized care in addressing these distressing symptoms

    Implementation of a novel continuous fetal Doppler (Moyo) improves quality of intrapartum fetal heart rate monitoring in a resource-limited tertiary hospital in Tanzania: An observational study.

    No full text
    BACKGROUND:Intrapartum Fetal Heart Rate (FHR) monitoring is crucial for the early detection of abnormal FHR, facilitating timely obstetric interventions and thus the potential reduction of adverse perinatal outcomes. We explored midwifery practices of intrapartum FHR monitoring pre and post implementation of a novel continuous automatic Doppler device (the Moyo). METHODOLOGY:A pre/post observational study among low-risk pregnancies at a tertiary hospital was conducted from March to December 2016. In the pre-implementation period, intermittent monitoring was conducted with a Pinard stethoscope (March to June 2016, n = 1640 women). In the post-implementation period, Moyo was used for continuous FHR monitoring (July-December 2016, n = 2442 women). The primary outcome was detection of abnormal FHR defined as absent, FHR160bpm. The secondary outcomes were rates of assessment/documentation of FHR, obstetric time intervals and intrauterine resuscitations. Chi-square test, Fishers exact test, t-test and Mann-Whitney U test were used in bivariate analysis whereas binary and multinomial logistic regression were used for multivariate. RESULTS:Moyo use was associated with greater detection of abnormal FHR (8.0%) compared with Pinard (1.6%) (p<0.001). There were higher rates of non-assessment/documentation of FHR pre- (45.7%) compared to post-implementation (2.2%) (p<0.001). At pre-implementation, 8% of deliveries had FHR documented as often as ≤ 60 minutes, compared to 51% post-implementation (p<0.001). Implementation of continuous FHR monitoring was associated with a shorter time interval from the last FHR assessment to delivery i.e. median (IQR) of 60 (30,100) to 45 (21,85) minutes (p<0.001); and shorter time interval between each FHR assessment i.e. from 150 (86,299) minutes to 60 (41,86) minutes (p<0.001). Caesarean section rates increased from 2.6 to 5.4%, and vacuum deliveries from 2.2 to 5.8% (both p<0.001). Perinatal outcomes i.e. fresh stillbirths and early neonatal deaths were similar between time periods. The study was limited by both lack of randomization and involvement of low-risk pregnant women with fewer adverse perinatal outcomes than would be expected in a high-risk population. CONCLUSION:Implementation of the Moyo device, which continuously measures FHR, was associated with improved quality in FHR monitoring practices and the detection of abnormal FHR. These improvements led to more frequent and timely obstetric responses. Follow-up studies in a high-risk population focused on a more targeted description of the FHR abnormalities and the impact of intrauterine resuscitation is a critical next step in determining the effect on reducing perinatal mortality

    Characteristics of participants in in-depth interviews.

    No full text
    <p>ID no with a = Option A, with b = Option B, with b+ = option B also asked about B+.</p><p>Marital status: Mar = Married, Div  = divorced, Cohab = cohabiting.</p><p>Business  =  small-scale business.</p
    corecore