    Harbour porpoises are one of the three cetacean species inhabiting the Black Sea. This is the first study to report on polybrominated diphenyl ethers (PBDEs) and naturally-produced compounds, methoxylated PBDEs (MeO-PBDEs) and polybrominated hexahydroxanthene derivatives (PBHDs), in tissues (kidney, brain, blubber, liver, muscle) of male harbour porpoises (11 adults, 9 juveniles) from the Black Sea. Lipid-normalized concentrations decreased from muscle > blubber > liver > kidney > brain for the sum of polychlorinated biphenyls (PCBs) and for the sum of PBDEs. Among the naturally-produced compounds, levels of PBHDs were higher than of MeO-PBDEs, with tri-BHD and 6-MeO-BDE 47 being the dominant compounds for both groups, respectively. Concentrations of naturally-produced compounds decreased from blubber to brain, similarly to the sum of DDT and metabolites (DDXs). Concentrations of DDXs were highest, followed by PCBs, HCB, PBHDs, PBDEs and MeO-PBDEs. Levels of PCBs and PBDEs in blubber were lower than concentrations reported for harbour porpoises from the North Sea, while concentrations of DDXs were higher

    Analytical performance of eight enzymatic assays for ethanol in serum evaluated by data from the Belgian external quality assessment scheme

    Full text link
    Abstract Objectives Fast and reliable ethanol assays analysis are used in a clinical context for patients suspected of ethanol intoxication. Mostly, automated systems using an enzymatic reaction based on ethanol dehydrogenase are used. The manuscript focusses on the evaluation of the performance of these assays. Methods Data included 30 serum samples used in the Belgian EQA scheme from 2019 to 2021 and concentrations ranged from 0.13 to 3.70 g/L. A regression line between target concentrations and reported values was calculated to evaluate outliers, bias, variability and measurement uncertainty. Results A total of 1,611 results were taken into account. Bias was the highest for Alinity c over the whole concentration range and the lowest for Vitros for low concentrations and Cobas 8000 using the c702 module for high concentrations. The Architect and Cobas c501/c502 systems showed the lowest variability over the whole concentration range. Highest variability was observed for Cobas 8000 using the 702 module, Thermo Scientific and Alinity c. Cobas 8000 using the c702 module showed the highest measurement uncertainty for lower concentrations. For higher concentrations, Alinity c, Thermo Scientific and Vitros were the methods with the highest measurement uncertainty. Conclusions The bias of the enzymatic techniques is nearly negligible for all methods except Alinity c. Variability differs strongly between measurement procedures. This study shows that the Alinity c has a worse measurement uncertainty than other systems for concentrations above 0.5 g/L. Overall, we found the differences in measurement uncertainty to be mainly influenced by the differences in variability
    • …
    corecore