39 research outputs found

    House Dust Mite Exposure Causes Increased Susceptibility of Nasal Epithelial Cells to Adenovirus Infection

    Get PDF
    Adenovirus (AdV) infections in the respiratory tract may cause asthma exacerbation and allergic predisposition, and the house dust mite (HDM) may aggravate virus-induced asthma exacerbations. However, the underlying mechanisms of whether and how AdV affects asthmatic patients remains unclear. To address this question, we investigated nasal epithelial cells (NAEPCs) derived from a pediatric exacerbation study cohort for experimental analyses. We analyzed twenty-one different green-fluorescent protein- and luciferase-tagged AdV types in submerged 2D and organotypic 3D cell culture models. Transduction experiments revealed robust transduction of AdV type 5 (AdV5) in NAEPCs, which was associated with an increased uptake of AdV5 in the presence of HDM. In healthy and asthmatic NAEPCs exposed to HDM before infection, we observed a time- and dose-dependent increase of AdV5 uptake associated with upregulation of entry receptors for AdV5. Furthermore, electron microscopic and histologic analyses of 3D cell cultures revealed an impairment of the respiratory cilia after HDM exposition. This ex vivo pilot study shows the impact of AdV infection and HDM exposition in a primary cell culture model for asthma

    Fluoride bioavailability in saliva and plaque

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Different fluoride formulations may have different effects on caries prevention. It was the aim of this clinical study to assess the fluoride content, provided by NaF compared to amine fluoride, in saliva and plaque.</p> <p>Methods</p> <p>Eight trained volunteers brushed their teeth in the morning for 3 minutes with either NaF or amine fluoride, and saliva and 3-day-plaque-regrowth was collected at 5 time intervals during 6 hours after tooth brushing. The amount of collected saliva and plaque was measured, and the fluoride content was analysed using a fluoride sensitive electrode. All subjects repeated all study cycles 5 times, and 3 cycles per subject underwent statistical analysis using the Wilcoxon-Mann-Whitney test.</p> <p>Results</p> <p>Immediately after brushing the fluoride concentration in saliva increased rapidly and dropped to the baseline level after 360 minutes. No difference was found between NaF and amine fluoride. All plaque fluoride levels were elevated after 30 minutes until 120 minutes after tooth brushing, and decreasing after 360 minutes to baseline. According to the highly individual profile of fluoride in saliva and plaque, both levels of bioavailability correlated for the first 30 minutes, and the fluoride content of saliva and plaque was back to baseline after 6 hours.</p> <p>Conclusions</p> <p>Fluoride levels in saliva and plaque are interindividually highly variable. However, no significant difference in bioavailability between NaF and amine fluoride, in saliva, or in plaque was found.</p

    Microleakage of Different Self-Adhesive Materials for Lithium Disilicate CAD/CAM Crowns

    No full text
    Objectives: To evaluate the microleakage and marginal gap of various luting materials after cementing ceramic crowns. Methods: Cervical margins of human molars were designed as circular chamfers. Cementation of full-contour ceramic crowns was conducted with zinc-phosphate cement (Harvard cement), resin cement (Panavia F 2.0) and self-adhesive resin cements (RelyX Unicem, BifixSE, MaxCem Elite, PermaCem2.0, G-Cem). Aging of specimens was performed in artificial saliva, at 37 °C for four weeks and thermocycling. The marginal gap was measured with a scanning electron microscope and silver precipitation within the microleakage. All data were compared statistically. Results: Independent of the margin preparation, the highest median value for microleakage was 320.2 μm (Harvard cement), and the lowest was 0 μm (Panavia F 2.0). The median value for enamel was 0 µm and for dentin 270.9 μm (p &lt; 0.001), which was independent of the luting material. The marginal and absolute marginal gaps were not significantly different between the tested materials. There was no correlation between microleakage and the marginal gaps. Conclusion: Significant differences in microleakage were found between the tested luting materials (p &lt; 0.05). Independent from the luting materials, the microleakage in dentin showed significantly higher values than in enamel

    Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists

    No full text
    Objective: Evaluation of wear behavior of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns from various restorative materials and natural antagonists. Method: Full CAD/CAM crowns fabricated with nanoceramic resin (Lava Ultimate (LU)), a glass ceramic in a resin interpenetrating matrix (Vita Enamic (VE)) and a lithium silicate reinforced ceramic enriched with zirconia (Vita Suprinity (VS)) were cemented on human molars. The crown and antagonists were subjected to simulated chewing. 3D data sets, before and after the chewing simulation, were generated and matched. Occlusal surface roughness, vertical and volume loss of the crowns and antagonists were analyzed. Results: Crown roughness was significantly different between the LU and VE groups after chewing simulation. Crown vertical loss differed in all groups. The highest crown volume loss was found in the LU group, and the lowest in the VE group. Comparisons between the LU and VE groups and the LU and VS groups were significantly different. The highest antagonist volume loss was reached in the VE group, the lowest was in the LU group. Conclusion: Roughness increased after chewing simulation. LU crowns are the most natural antagonist-friendly; these were the most susceptible to vertical and volume loss. Of the tested materials, the VE crowns are the most stable regarding occlusion

    Effects of fluoridated milk on root dentin remineralization.

    No full text
    The prevalence of root caries is increasing with greater life expectancy and number of retained teeth. Therefore, new preventive strategies should be developed to reduce the prevalence of root caries. The aim of this study was to investigate the effects of fluoridated milk on the remineralization of root dentin and to compare these effects to those of sodium fluoride (NaF) application without milk.Thirty extracted human molars were divided into 6 groups, and the root cementum was removed from each tooth. The dentin surface was demineralized and then incubated with one of the following six solutions: Sodium chloride NaCl, artificial saliva, milk, milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Serial sections were cut through the lesions and investigated with polarized light microscopy and quantitative morphometry, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). The data were statistically evaluated using a one-way ANOVA for multiple comparisons.The depth of the lesion decreased with increasing fluoride concentration and was the smallest after incubation with artificial saliva+10 ppm fluoride. SEM analysis revealed a clearly demarcated superficial remineralized zone after incubation with milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Ca content in this zone increased with increasing fluoride content and was highest after artificial saliva+10 ppm fluoride incubation. In the artificial saliva+10 ppm fluoride group, an additional crystalline layer was present on top of the lesion that contained elevated levels of F and Ca.Incubation of root dentin with fluoridated milk showed a clear effect on root dentin remineralization, and incubation with NaF dissolved in artificial saliva demonstrated a stronger effect

    Polishing of Monolithic Zirconia Crowns—Results of Different Dental Practitioner Groups

    No full text
    This pilot study evaluates the surface roughness of monolithic zirconia crowns after chairside polishing by different dental practitioner groups. Four practitioner groups (group I: dental clinical students (n = 6); group II: dentists &lt; 2 years post-qualification experience (n = 6); group III: dentists &gt; 2 years post-qualification experience (n = 6) and group IV: dental technicians (n = 6)) were asked to polish two CAD/CAM-fabricated full-contour zirconia crowns (48 in total). A two-step zirconia polishing kit was used in both trials. The first trial (T1) was conducted without a time limitation. In the second trial (T2), the polish was restricted to 15 seconds for each polisher. Two blinded investigators (I1 and I2) analyzed the surface roughness (Ra) before and after polishing (Alicona measuring system). No statistically significant difference in surface roughness was found between the polishing results of the dental practitioner groups. Major difference in surface finish was achieved by dental technicians, with a median value of 25.4 nm (interquartile range 10.15–35.26 nm) for I1 in T1. The lowest difference was achieved by dental students, with a median value of Ra = 6.72 nm (interquartile range 4.7–17.9 nm) in T1. In T2, experienced dentists showed the highest difference in surface finish, with a median value of 41.35 nm (interquartile range 7.77–54.11). No significant correlation was found between polishing time and polishing results. The polishing of monolithic zirconium dioxide crowns can be performed with the present polishing set directly chairside after occlusal adjustment, regardless of the practitioner’s experience level

    Microleakage of Different Self-Adhesive Materials for Lithium Disilicate CAD/CAM Crowns

    No full text
    Objectives: To evaluate the microleakage and marginal gap of various luting materials after cementing ceramic crowns. Methods: Cervical margins of human molars were designed as circular chamfers. Cementation of full-contour ceramic crowns was conducted with zinc-phosphate cement (Harvard cement), resin cement (Panavia F 2.0) and self-adhesive resin cements (RelyX Unicem, BifixSE, MaxCem Elite, PermaCem2.0, G-Cem). Aging of specimens was performed in artificial saliva, at 37 °C for four weeks and thermocycling. The marginal gap was measured with a scanning electron microscope and silver precipitation within the microleakage. All data were compared statistically. Results: Independent of the margin preparation, the highest median value for microleakage was 320.2 μm (Harvard cement), and the lowest was 0 μm (Panavia F 2.0). The median value for enamel was 0 µm and for dentin 270.9 μm (p &lt; 0.001), which was independent of the luting material. The marginal and absolute marginal gaps were not significantly different between the tested materials. There was no correlation between microleakage and the marginal gaps. Conclusion: Significant differences in microleakage were found between the tested luting materials (p &lt; 0.05). Independent from the luting materials, the microleakage in dentin showed significantly higher values than in enamel

    Fluoride release from two types of fluoride-containing orthodontic adhesives: Conventional versus resin-modified glass ionomer cements-An in vitro study.

    No full text
    IntroductionDevelopment of white spot lesions (WSLs) during orthodontic treatment is a common risk factor. Fixation of the orthodontic appliances with glass ionomer cements could reduce the prevalence of WSL's due to their fluoride release capacities. The purpose of this study was to evaluate differences of fluoride release properties from resin-modified and conventional glass ionomer cements (GICs).MethodsThe resin-modified GICs Fuji ORTHO LC (GC Orthodontics), Meron Plus QM (VOCO), as well as the conventional GICs Fuji ORTHO (GC Orthodontics), Meron (VOCO) and Ketac Cem Easymix (3M ESPE) were tested in this study. The different types of GICs were applied to hydroxyapatite discs according to the manufacturer's instructions and stored in a solution of TISAB III (Total Ionic Strength Adjustment Buffer III) and fluoride-free water at 37°C. Fluoride measurements were made after 5 minutes, 2 hours, 24 hours, 14 days, 28 days, 2 months, 3 months and 6 months. One factor analysis of variance (ANOVA) was used for the overall comparison of the cumulative fluoride release (from measurement times of 5 minutes to 6 months) between the different materials with the overall level of significance set to 0.05. Tukey's post hoc test was used for post hoc pairwise comparisons in the cumulative fluoride release between the different materials.ResultsThe cumulative fluoride release (mean ± sd) in descending order was: Fuji ORTHO LC (221.7 ± 10.29 ppm), Fuji ORTHO (191.5 ± 15.03 ppm), Meron Plus QM (173.0 ± 5.89 ppm), Meron (161.3 ± 7.84 ppm) and Ketac Cem Easymix (154.6 ± 6.09 ppm) within 6 months. Analysis of variance detected a significant difference in the cumulative fluoride release between at least two of the materials (rounded p-value ConclusionFluoride ions were released cumulatively over the entire test period for all products. When comparing the two products from the same company (Fuji ORTHO LC vs. Fuji ORTHO from GC Orthodontics Europe GmbH and Meron Plus QM vs. Meron from VOCO GmbH, Mannheim, Germany), it can be said that the resin-modified GICs have a higher release than conventional GICs. The highest individual fluoride release of all GICs was at 24 hours. A general statement, whether resin-modified or conventional GICs have a higher release of fluoride cannot be made

    Influence of Luting Materials on the Retention of Cemented Implant-Supported Crowns: An In Vitro Study

    No full text
    The retention force of cemented crowns on implant abutments with various luting materials was evaluated. Cobalt&ndash;chromium crowns were cemented onto tapered titanium abutments (Camlog) with eugenol-free temporary cement (RelyX TempBond NE), composite-based temporary cement (Bifix Temp), zinc phosphate cement (Harvard Cement), glass-ionomer cements (Meron, Fuji I), and resin-modified glass-ionomer cements (Fuji II, Fuji Plus, Ketac Cem Plus). Specimen aging via hydrostress was performed in artificial saliva at 37 &deg;C for 14 days (S1), followed by hydrothermal stress with thermocycling (S2). The crowns were removed, and the force was recorded (T1). Subsequently, the crowns were recemented, aged, and removed, and the force was recorded (T2, T3). The retention forces differences were statistically significant according to the storage conditions at T1 (p = 0.002) and T3 (p = 0.0002). After aging (S1), Ketac Cem Plus had the highest retention force median value difference (T3 versus T1) (&minus;773 N), whereas RelyX TempBond NE had the lowest (&minus;146 N). After aging (S2), Meron had the highest retention force median value difference (&minus;783 N), whereas RelyX TempBond NE had the lowest (&minus;168 N). Recementation decreased the retention force of the implant-supported cobalt&ndash;chromium crowns cemented and recemented with the same luting materials. Luting materials (at T1) and aging conditions significantly impacted the retention force
    corecore