31 research outputs found

    Modeling space-resolved ion dynamics in ECR plasmas for predicting in-plasma β-decay rates

    Get PDF
    Lifetimes of radioactive nuclei are known to be affected by the level configurations of their respective atomic shells. Immersing such isotopes in environments composed of energetic charged particles such as stellar plasmas can result in β-decay rates orders of magnitude different from those measured terrestrially. Accurate knowledge of the relation between plasma parameters and nuclear decay rates are essential for reducing uncertainties in present nucleosynthesis models, and this is precisely the aim of the PANDORA experiment. Currently, experimental evidence is available for fully stripped ions in storage rings alone, but the full effect of a charge state distribution (CSD) as exists in plasmas is only modeled theoretically. PANDORA aims to be the first to verify these models by measuring the β-decay rates of select isotopes embedded in electron cyclotron resonance (ECR) plasmas. For this purpose, it is necessary to consider the spatial inhomogeneity and anisotropy of plasma ion properties as well as the non-local thermodynamic equilibrium (NLTE) nature of the system. We present here a 3D ion dynamics model combining a quasi-stationary particle-in-cell (PIC) code to track the motion of macroparticles in a pre-simulated electron cloud while simultaneously using a Monte Carlo (MC) routine to check for relevant reactions describing the ion population kinetics. The simulation scheme is robust, comprehensive, makes few assumptions about the state of the plasma, and can be extended to include more detailed physics. We describe the first results on the 3D variation of CSD of ions both confined and lost from the ECR trap, as obtained from the application of the method to light nuclei. The work culminates in some perspectives and outlooks on code optimization, with a potential to be a powerful tool not only in the application of ECR plasmas but for fundamental studies of the device itself

    An Innovative Superconducting Magnetic Trap for Probing β-decay in Plasmas

    Get PDF
    The main aim of Plasmas for Astrophysics Nuclear Decays Observation and Radiation for Archaeometry (PANDORA) project is to build a compact and flexible magnetic plasma trap where plasma reaches a densityne∼ 1011–1013 cm−3, and a temperature, in units ofkT,kTe∼ 0.1–30 keV in order to measure, for the first time, nuclearβ-decay rates in stellar-like conditions. One of the most important aspects of an ECR Ion Source (ECRIS) is its magnetic system. In this paper, the numerical design of the PANDORA magnetic system is presented and validated by using the commercial simulators OPERA and CST Studio Suite, showing an excellent agreement between each other in terms of axial and radial field profiles. In conjunction to the magnetic system design, the overall injection system, including the microwave lines for plasma heating and the isotopes injection schemes with a focus on the developments of the oven for solid elements, has been conceived and will be discussed

    Design study of a HPGe detector array for β-decay investigation in laboratory ECR plasmas

    Get PDF
    In the frame of the PANDORA project, a new experimental approach aims at measuring in-plasma β-decay rate as a function of thermodynamical conditions of the environment, namely a laboratory magnetized plasma able to mimic some stellar-like conditions. The decay rates (expected to change dramatically as a function of the ionization state) will be measured as a function of the charge state distribution of the in-plasma ions. The new experimental approach aims at correlating the plasma environment and the decay rate. This can be performed by simultaneously identifying and discriminating—through an innovative multi-diagnostic system working synergically with a γ-ray detection system —the photons emitted by the plasma and γ-rays emitted after the isotope β-decay. In this study, the numerical simulations supporting the design of the γ-ray detector array, including a statistical significance study to check the feasibility of measuring the in-plasma decay rates, are presented. Geant4 simulations focused on the design of the array of γ-ray detectors and the evaluation of total efficiency depending on the detector type and the optimal displacement of detectors around the trap (including collimation systems and shielding). The simulation results showed that, due to technical limitations in the number of apertures that can be created in the magnetic trap, the best compromise is to use 14 HPGe (70% of relative efficiency) detectors surrounding the magnetic trap. The HPGe detectors were chosen for their excellent energy resolution (0.2% @ 1 MeV), since the harsh environment (the background is represented by the intense plasma self-emission) strongly affects the signal-to-background ratio. Once determined the total photopeak efficiency (0.1–0.2%), the sensitivity of the PANDORA experiment was checked in a "virtual experimental run," by exploring the measurability of isotope decay rates for the first three physical cases of PANDORA: 176Lu, 134Cs and 94Nb. The preliminary results demonstrated the feasibility of the measurement in terms of the signal-to-background ratio and significance that it is possible to reach. The results indicated that experimental run durations could take from several days to 3 months, depending on the isotope under investigation, thus shedding new light on the role of weak interactions in stellar nucleosynthesis

    Experimental and numerical investigation of magneto-plasma optical properties toward measurements of opacity relevant for compact binary objects

    Get PDF
    Electromagnetic transients known as kilonovae (KN), are among the photonic messengers released in the post-merger phase of compact binary objects, for example, binary neutron stars, and they have been recently observed as the electromagnetic counterpart of related gravitational-wave (GW) events. Detection of the KN signal plays a fundamental role in the multi-messenger astronomy entering in a sophisticated GW-detecting network. The KN light curve also delivers precious information on the composition and dynamics of the neutron-rich post-merger plasma ejecta (relying on r-process nucleosynthesis yields). In this sense, studying KN becomes of great relevance for nuclear astrophysics. Because of the highly heterogeneous composition, plasma opacity has a great impact both on radiative transport and spectroscopic observation of KN. Theoretical models attempting in encoding the opacity of this system often fail, due to the complexity of blending plethora of both light- and heavy-r nuclei transition lines, requesting for more complete atomic database. Trapped magneto-plasmas conceived in PANDORA could answer to these requests, allowing experimental in-laboratory measurements of optical properties and opacities, at plasma electron densities and temperatures resembling early-stage plasma ejecta’s conditions, contributing to shed light on r-process metallic species abundance at the blue-KN diffusion time. A numerical study has been recently performed, supporting the choice of first physics cases to be investigated and the design of the experimental setup. In this article, we report on the feasibility of metallic plasmas on the basis of the results from the systematic numerical survey on optical spectra computed under non-local thermodynamic equilibrium (NLTE) for several light-r nuclei. Results show the great impact of the NLTE regime of laboratory magneto-plasmas on the gray opacity contribution contrasted with those under the astrophysical LTE assumption. A first experimental attempt of reproducing ejecta plasma conditions has been performed on the operative Flexible Plasma Trap (FPT) at the INFN-LNS and here presented, together with first plasma characterization of density and temperature, via non-invasive optical emission spectroscopy (OES). The measured plasma parameters have supported numerical simulations to explore optical properties of NLTE gaseous and metallic plasmas, in view of the near-future plasma opacity measurements through spectroscopic techniques. The novel work so far performed on these under-dense and low-temperature magneto-plasmas, opens the route for the first-time to future in-laboratory plasma opacity measurements of metallic plasma species relevant for KN light curve studies

    Robotic Radical Prostatectomy: What Do We Really Know about Its Outcomes?

    No full text

    Confocal Laser Endomicroscopy for Bladder Cancer Detection: Where Do We Stand?

    No full text
    Introduction: Confocal laser endomicroscopy (CLE) is a relatively new technology that allows for a real-time in situ microscopic characterization of tissue lesions, being able to discriminate between low- and high-grade ones. After a first period of slow diffusion caused by technological limitations and elevated costs, CLE applications are rapidly spreading in different branches of medicine, and there is mounting evidence of its advantages for the management of different tumors such as bladder cancer (BCa), from both a diagnostic and a clinical point of view. In this systematic review (SR), we evaluate the state-of-the-art CLE for BCa management. Material and methods: We performed an SR and quality assessment analysis of the current literature in this regard following the PRISMA guidelines. All data were independently verified by two different authors and discrepancies were solved by a third author. Moreover, a quality-assessment analysis according to QUADAS-2 criteria was performed to evaluate the studies selected for SR. Results: A total of 158 articles were retrieved; of which 79 were rejected and 38 were removed as duplicates. After article selection, seven prospective studies were assessed for data extraction. These accounted for 214 patients overall, with a correspondence rate between CLE and histopathological examination ranging from 54.6 to 93.6%. Regarding quality assessment, three out five prospective studies have at least a high risk of bias in one QUADAS-2 domain, whereas the applicability always has a low risk of bias. Conclusion: Despite actual technical limitations, the preliminary results of this appealing technology are encouraging and should prompt further investigations
    corecore