11 research outputs found

    Homogeneity Of The Geochemical Reference Material Brp-1 (paranábasin Basalt) And Assessment Of Minimum Mass

    No full text
    Reference materials (RM) are required for quantitative analyses and their successful use is associated with the degree of homogeneity, and the traceability and confidence limits of the values established by characterisation. During the production of a RM, the chemical characterisation can only commence after it has been demonstrated that the material has the required level of homogeneity. Here we describe the preparation of BRP-1, a proposed geochemical reference material, and the results of the tests to evaluate its degree of homogeneity between and within bottles. BRP-1 is the first of two geochemical RM being produced by Brazilian institutions in collaboration with the United States Geological Survey (USGS) and the International Association of Geoanalysts (IAG). Two test portions of twenty bottles of BRP-1 were analysed by wavelength dispersive-XRF spectrometry and major, minor and eighteen trace elements were determined. The results show that for most of the investigated elements, the units of BRP-1 were homogeneous at conditions approximately three times more rigorous than those strived for by the test of "sufficient homogeneity". Furthermore, the within bottle homogeneity of BRP-1 was evaluated using small beam (1 mm 2) synchrotron radiation XRF spectrometry and, for comparison, the USGS reference materials BCR-2 and GSP-2 were also evaluated. From our data, it has been possible to assign representative minimum masses for some major constituents (1 mg) and for some trace elements (1-13 mg), except Zr in GSP-2, for which test portions of 74 mg are recommended. © 2007 International Association of Geoanalysts.314379393Dybczynski, R., Danko, B., Polkowska-Motrenko, H., NAA study on homogeneity of reference materials and their suitability for microanalysis techniques (2000) Journal of Radioanalytical and Nuclear Chemistry, 245, pp. 97-104Dybczynski, R., Preparation and use of reference materials for quality assurance in inorganic trace analysis (2002) Food Additives and Contaminants, 19, pp. 928-938Fearn, T., Thompson, M., A new test for "sufficient homogeneity" (2001) The Analyst, 126, pp. 1414-1417Friese, K.C., Grobecker, K.H., Wätjen, N.D.U., Development of an electrothermal vaporization ICP-MS method and assessment of its applicability to studies of the homogeneity of reference materials (2001) Fresenius' Journal of Analytical Chemistry, 370, pp. 499-507Holcombe, G., Lawn, R., Sargent, M., Improvements in efficiency of production and traceability for certification of reference materials (2004) Accreditation and Quality Assurance, 9, pp. 198-204Horwitz, W., Albert, R., Precision in analytical measurements: Expected values and consequences in geochemical analyses (1995) Fresenius' Journal of Analytical Chemistry, 351, pp. 507-513Ingamells, C.O., Switzer, P., Proposed sampling constant for use in geochemica analysis (1973) Talanta, 20, pp. 547-568(2006) Reference Materials - General and Statistical Principles for Certification, p. 64. , ISO Guide 35 International Organisation for Standardisation (Geneva)Jenkins, R., de Vries, J.L., (1970) Practical X-ray Spectrometry, p. 190. , (2nd edition). Springer-Verlag (New York)Kane, J.S., Potts, P.J., An interpretation of ISO guidelines for the certification of geological reference materials (1999) Geostandards Newsletter: The Journal of Geostandards and Geoanalysis, 23, pp. 209-221Kane, J.S., Potts, P.J., Wiedenbeck, M., Carignan, J., Wilson, S., International Association of Geoanalysts protocol for the certification of geological and environmental reference materials (2003) Geostandards Newsletter: The Journal of Geostandards and Geoanalysis, 27, pp. 227-244Kempenaers, L., Vincze, L., Janssens, K., The use of synchrotron micro-XRF for characterization of the micro-heterogeneity of heavy metals in low-Z reference materials (2000) Spectrochimica Acta Part B, 55, pp. 651-669Kempenaers, L., Janssens, K., Jochum, K.P., Vincze, L., Vekemans, B., Somogyi, A., Drakopoulos, M., Adams, F., Micro-heterogeneity study of trace elements in USGS, MPI-DING and NIST glass reference materials by means of synchrotron micro-XRF (2003) Journal Analytical Atomic Spectrometry, 18, pp. 350-357Kurfürst, U., Grobecker, K.H., Stoeppler, M., Problems of sampling and sample preparation for trace element analysis in the health sciences (1984) Trace Elements - Analytical Chemistry in Medicine and Biology, pp. 591-601. , In: Bratter P. and Schramel P. (eds) W de Gruyter (Berlin)Kurfürst, U., Pauwels, J., Grobecker, K.H., Stoeppler, M., Muntau, H., Micro-heterogeneity of trace elements in reference materials - Determination and statistical evaluation (1993) Fresenius' Journal of Analytical Chemistry, 345, pp. 112-120Lankosz, M., Szczerbowska-Boruchowska, M., Chwiej, J., Ostachowicz, J., Simionovici, A., Bohic, S., Research in quantitative microscopic X-ray fluorescence analysis (2004) Spectrochimica Acta Part B - Atomic Spectroscopy, 59, pp. 1517-1521Linsinger, T.P.J., Pauwels, J., Van der Veen, A.M.H., Schimmel, H., Lamberty, A., Homogeneity and stability of reference materials (2001) Accreditation and Quality Assurance, 6, pp. 20-25Lozano, R., Bernal, J.P., Characterization of a new set of eight geochemical reference materials for XRF major and trace element analysis (2005) Mexican Magazine of Geologic Sciences, 22, pp. 329-344Makishima, A., Nakamura, E., Determination of major, minor and trace elements in silicate samples by ICP-QMS and ICP-SFMS applying isotope dilution-internal standardisation (ID-IS) and multi-stage internal standardisation (2006) Geostandards and Geoanalytical Research, 30, pp. 245-271Miller-Ihli, N.J., Baker, S.A., Homogeneity assessments using ultrasonic slurry sampling coupled with electrothermal vaporization isotope dilution inductively coupled plasma-mass spectrometry (2001) Spectrochimica Acta Part B - Atomic Spectroscopy, 56, pp. 1673-1686Pauwels, J., Lamberty, A., Schimmel, H., Homogeneity testing of reference materials (1998) Accreditation and Quality Assurance, 3, pp. 51-55Pérez, C.A., Radtke, M., Sanchez, H.J., Tolentino, H., Neuenshwander, R.T., Barg, W., Rubio, M., Rohwedder, J.J.R., Synchrotron radiation X-ray fluorescence at the LNLS: Beamline instrumentation and experiments (1999) X-Ray Spectrometry, 28, pp. 320-326Potts, P.J., (1987) A Handbook of Silicate Rock Analysis, p. 622. , Chapman and Hall (New York)Potts, P.J., Williams-Thorpe, O., Webb, P.C., The bulk analysis of silicate rocks by portable X-ray fluorescence: Effect of sample mineralogy in relation to the size of the excited volume (1997) Geostandards Newsletter: The Journal of Geostandards and Geoanalysis, 21, pp. 29-41Potts, P.J., Kane, J.S., International Association of Geoanalysts certificate of analysis: Certified reference material OU-6 (Penrhyn slate) (2005) Geostandards and Geoanalytical Research, 29, pp. 233-236Rossbach, M., Grobecker, K.H., Homogeneity studies of reference materials by solid sampling - AAS and INAA (1999) Accreditation and Quality Assurance, 4, pp. 498-503Rossbach, M., Zeiller, E., Assessment of element-specific homogeneity in reference materials using microanalytical techniques (2003) Analytical and Bioanalytical Chemistry, 377, pp. 334-339Rossbach, M., Ostapczuk, P., Emons, H., Microhomogeneity of candidate reference materials: Comparison of solid sampling Zeeman-AAS with INAA (1998) Fresenius' Journal of Analytical Chemistry, 360, pp. 380-383Thompson, M., Test for "sufficient homogeneity"in a reference material (2004) Royal Society of Chemistry, , http://www.fapas.com/pdfpub/Paper2Amc%20recommendation.pdf, (Accessed in 2006:)Thompson, M., Wood, R., International harmonized protocol for proficiency testing of (chemical) analytical laboratories (1993) Journal of AOAC International, 76, pp. 926-940Tong, C.H., Zhou, S.C., Li, J.C., Liu, X.H., Wu, J.P., The preparation and characteristics of the geochemical certified reference material BEM (Emeishan Basalt) (2005) Geostandards and Geoanalytical Research, 29, pp. 225-231Van der Veen, A.M.H., Linsinger, T., Pauwels, J., Uncertainty calculations in the certification of reference materials. 2. Homogeneity study (2001) Accreditation Quality Assurance, 6, pp. 26-30Vendemiatto, M.A., Enzweiler, J., Routine control of accuracy in silicate rock analysis by X-ray fluorescence spectrometry (2001) Geostandards Newsletter: The Journal of Geostandards and Geoanalysis, 25, pp. 283-291Venelinov, T., Sahuquillo, A., Optimizing the uses and the costs of reference materials in analytical laboratories (2006) Trends in Analytical Chemistry, 25, pp. 528-533Vincze, L., Janssens, K., Adams, F., Jones, K.W., A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers. Part 3. Polarized polychromatic radiation, homogeneous samples (1995) Spectrochimica Acta Part B - Atomic Spectroscopy, 50, pp. 1481-1500Zeisler, R., Reference material for small-sample analysis (1998) Fresenius' Journal of Analytical Chemistry, 360, pp. 376-379
    corecore