6,829 research outputs found

    Fatigue resistance of new and used nickel-titanium rotary instruments: a comparative study

    Get PDF
    Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones

    In vivo evaluation of operative torque generated by two Nickel-Titanium rotary instruments during root canal preparation

    Get PDF
    Objectives This in vivo study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars. Materials and Methods Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (n = 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds). Statistical Analysis Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann-Whiney U test with a significance level set at 5%. Results No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (p > 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2-9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35-21.1) (p < 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18-0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05-0.17) (p < 0.05). Conclusions Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals

    Role of the flat-designed surface in improving the cyclic fatigue resistance of endodontic NiTi rotary instruments

    Get PDF
    The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel-titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon-Mann-Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p < 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments

    Multiset Subdivision

    Get PDF

    Symbolic computation of moments of sampling distributions

    Full text link
    By means of the notion of umbrae indexed by multisets, a general method to express estimators and their products in terms of power sums is derived. A connection between the notion of multiset and integer partition leads immediately to a way to speed up the procedures. Comparisons of computational times with known procedures show how this approach turns out to be more efficient in eliminating much unnecessary computation.Comment: 21 pages, 7 table

    Decommissioning of Offshore Platforms in Adriatic Sea: The Total Removal Option from a Life Cycle Assessment Perspective

    Get PDF
    The international energy scenario to date is heavily based on fossil energy sources such as coal, oil or natural gas. According to the international ecological goals of the UNFCCC formalized in the legally binding treaty called the Paris Agreement, the next global challenges will be the decommissioning, dismantling or reconversion of the current fossil energy system into a new, more sustainable system that makes more efficient use of renewable energy technologies. Worldwide, there are about 6500 offshore oil and gas facilities and about 130 of them are located in the Mediterranean basin, mainly in the Adriatic and Ionian Seas: more than 110 offshore gas platforms have been installed in these areas since 1960. In this paper, using Life Cycle Assessment, the environmental and economic impacts of the total removal operations of an existing offshore platform in the context of the Adriatic Sea are assessed based on existing and registered decommissioning projects. In addition, the avoided impacts of primary steel production due to its recovery and recycling from the removed platform are assessed using the system boundary expansion method

    Finite Temperature Effective Potential for Gauge Models in de Sitter Space

    Get PDF
    The one-loop effective potential for gauge models in static de Sitter space at finite temperatures is computed by means of the ζ\zeta--function method. We found a simple relation which links the effective potentials of gauge and scalar fields at all temperatures. In the de Sitter invariant and zero-temperature states the potential for the scalar electrodynamics is explicitly obtained, and its properties in these two vacua are compared. In this theory the two states are shown to behave similarly in the regimes of very large and very small radii a of the background space. For the gauge symmetry broken in the flat limit (a→∞a \to \infty) there is a critical value of a for which the symmetry is restored in both quantum states. Moreover, the phase transitions which occur at large or at small a are of the first or of the second order, respectively, regardless the vacuum considered. The analytical and numerical analysis of the critical parameters of the above theory is performed. We also established a class of models for which the kind of phase transition occurring depends on the choice of the vacuum.Comment: 23 pages, LaTeX, 5 figure.ep

    The influence of a new clinical motion for endodontic instruments on the incidence of postoperative pain

    Get PDF
    Previous studies showed that motor motions play an important role in determining apical extrusion of debris. Therefore a new clinical motion (MIMERACI) has been proposed. The basic idea is to progress slowly (1mm advancement), and after each 1mm, to remove the instrument from the canal, clean flutes and irrigate. The aim of the study was to prove whether the clinical use of MIMERACI technique would influence or not postoperative pain.MATERIALS AND METHODS: 100 teeth requesting endodontic treatment were selected for the study and divided into two similar groups based on anatomy, pre-operative symptoms and vitality, presence or absence of periapical lesion. All teeth were shaped, cleaned and obturated by the same operator, using the same NiTi instruments. The only difference between the two groups was the instrumentation technique: tradional (group A) vs MIMERACI (group B). Assessment of postoperative pain was performed 3 days after treatment. Presence, absence and degree of pain were recorded with a visual analogue scale (VAS), validated in previous studies. Collected data statistically analyzed using one-way ANOVA post hoc Tukey test. RESULTS: For VAS pain scores MIMERACI technique showed significantly better results than group A (p=0,031). Overall, both incidence and intensity of symptoms were significantly lower. Flare ups occurred in 3 patients, but none treated with the MIMERACI Technique. CONCLUSIONS: Since extruded debris can elicit more postoperative pain, results obtained by using MIMERACI technique are probably due to many factors: better mechanical removal and less production of debris and more efficient irrigation during instrumentation
    • …
    corecore