12 research outputs found

    Continuous and gradual photo-activation methods: influence on degree of conversion and crosslink density of composite resins

    No full text
    Thermal properties and degree of conversion (DC%) of two composite resins (microhybrid and nanocomposite) and two photo-activation methods (continuous and gradual) displayed by the light-emitting diode (LED) light-curing units (LCUs) were investigated in this study. Differential scanning calorimetry (DSC) thermal analysis technique was used to investigate the glass transition temperature (T-g) and degradation temperature. The DC% was determined by Fourier transform infrared spectroscopy (FT-IR). The results showed that the microhybrid composite resin presented the highest T-g and degradation temperature values, i.e., the best thermal stability. Gradual photo-activation methods showed higher or similar T-g and degradation temperature values when compared to continuous method. The Elipar Freelight 2 (TM) LCU showed the lowest T-g values. With respect to the DC%, the photo-activation method did not influence the final conversion of composite resins. However, Elipar Freelight 2 (TM) LCU and microhybrid resin showed the lowest DC% values. Thus, the presented results suggest that gradual method photo-activation with LED LCUs provides adequate degree of conversion without promoting changes in the polymer chain of composite resins. However, the thermal properties and final conversion of composite resins can be influenced by the kind of composite resin and LCU.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

    Técnica para avaliação da pressão arterial pulmonar de equinos durante o exercício progressivo em esteira rolante Technique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill

    No full text
    Objetivou-se ilustrar a técnica cirúrgica de implantação de introdutores para cateter de Swan Ganz na veia jugular, bem como o procedimento de canulação da artéria pulmonar de dez equinos adultos sem raça definida (SRD). Realizando medidas através do cateter de Swan Ganz implantado, objetivou-se ainda demonstrar os valores de pressão arterial pulmonar (PAP) durante um teste de esforço progressivo de intensidade submáxima realizado em esteira rolante. A técnica cirúrgica de implantação de introdutores para o cateter de Swan Ganz empregada, demonstrou-se de fácil e rápida realização. Os animais não apresentaram complicações frente ao introdutor implantado e o teste ergométrico foi realizado conforme proposto. A PAP se elevou ao longo do exercício seguindo o incremento de velocidade, sendo os maiores valores médios observados nos momentos de maior intensidade do esforço. Os valores médios de PAP aumentaram (p<0,05) às velocidades de 7,5m/s (39±3 mmHg) e 8,5m/s (41±3 mmHg), quando comparados aos valores mensurados no repouso (26±3mmHg). Entretanto, os valores de PAP encontrados no máximo de esforço realizado pelos equinos SRD deste ensaio (41±3mmHg), encontram-se abaixo dos valores descritos para outras raças para a mesma intensidade de esforço. A descrição detalhada da técnica ilustrada no presente trabalho, pode contribuir substancialmente na padronização de protocolos experimentais que propõem o acesso arterial pulmonar por meio da implantação de cateter de Swan Ganz em equinos. O teste ergométrico proposto foi eficaz em promover variações de PAP de acordo com o esforço realizado, demonstrando valores para equinos SRD que poderão ser usados como base para futuras avaliações.<br>The aim of this study was to illustrate the surgical implantation of Swan Ganz introducers into the jugular vein, as well as the pulmonary artery cannulation procedure using ten mixed breed (MB) adult horses. We also proposed to demonstrate pulmonary arterial pressure (PAP) values measured through the implanted Swan Ganz during one incremental submaximal exercise test performed on a treadmill. Surgical implantation of the Swan Ganz introducers has demonstrated to be easy and quick to perform. None of the animals showed signs of discomfort following the surgery and ergometric test was carried out as proposed. PAP increased proportionally with exercise intensity, and the major average values were recorded at the higher effort time points. The PAP average values increased (P<0.05) when treadmill speed reached 7.5m/s (39±3mmHg) and 8.5m/s (41±3mmHg), comparing to average values at rest (26±3mmHg). However, the PAP values observed at the maximal effort performed by the MB horses of this trial (41±3mmHg), are under the values described for other breeds at similar effort tests. The technique described in the present study contributes for the standardization of research protocols using arterial pulmonary access via Swan Ganz catheter implantation in horses. The ergometric test was effective to promote PAP changes according to the effort, showing PAP values for MB horses that can guide further investigations

    Técnica para avaliação da pressão arterial pulmonar de equinos durante o exercício progressivo em esteira rolante

    No full text
    Objetivou-se ilustrar a técnica cirúrgica de implantação de introdutores para cateter de Swan Ganz na veia jugular, bem como o procedimento de canulação da artéria pulmonar de dez equinos adultos sem raça definida (SRD). Realizando medidas através do cateter de Swan Ganz implantado, objetivou-se ainda demonstrar os valores de pressão arterial pulmonar (PAP) durante um teste de esforço progressivo de intensidade submáxima realizado em esteira rolante. A técnica cirúrgica de implantação de introdutores para o cateter de Swan Ganz empregada, demonstrou-se de fácil e rápida realização. Os animais não apresentaram complicações frente ao introdutor implantado e o teste ergométrico foi realizado conforme proposto. A PAP se elevou ao longo do exercício seguindo o incremento de velocidade, sendo os maiores valores médios observados nos momentos de maior intensidade do esforço. Os valores médios de PAP aumentaram (p<0,05) às velocidades de 7,5m/s (39±3 mmHg) e 8,5m/s (41±3 mmHg), quando comparados aos valores mensurados no repouso (26±3mmHg). Entretanto, os valores de PAP encontrados no máximo de esforço realizado pelos equinos SRD deste ensaio (41±3mmHg), encontram-se abaixo dos valores descritos para outras raças para a mesma intensidade de esforço. A descrição detalhada da técnica ilustrada no presente trabalho, pode contribuir substancialmente na padronização de protocolos experimentais que propõem o acesso arterial pulmonar por meio da implantação de cateter de Swan Ganz em equinos. O teste ergométrico proposto foi eficaz em promover variações de PAP de acordo com o esforço realizado, demonstrando valores para equinos SRD que poderão ser usados como base para futuras avaliações.The aim of this study was to illustrate the surgical implantation of Swan Ganz introducers into the jugular vein, as well as the pulmonary artery cannulation procedure using ten mixed breed (MB) adult horses. We also proposed to demonstrate pulmonary arterial pressure (PAP) values measured through the implanted Swan Ganz during one incremental submaximal exercise test performed on a treadmill. Surgical implantation of the Swan Ganz introducers has demonstrated to be easy and quick to perform. None of the animals showed signs of discomfort following the surgery and ergometric test was carried out as proposed. PAP increased proportionally with exercise intensity, and the major average values were recorded at the higher effort time points. The PAP average values increased (P<0.05) when treadmill speed reached 7.5m/s (39±3mmHg) and 8.5m/s (41±3mmHg), comparing to average values at rest (26±3mmHg). However, the PAP values observed at the maximal effort performed by the MB horses of this trial (41±3mmHg), are under the values described for other breeds at similar effort tests. The technique described in the present study contributes for the standardization of research protocols using arterial pulmonary access via Swan Ganz catheter implantation in horses. The ergometric test was effective to promote PAP changes according to the effort, showing PAP values for MB horses that can guide further investigations.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP

    Degree of conversion of different composite resins photo-activated with light-emitting diode and argon ion laser

    No full text
    This study evaluated the degree of conversion (DC%) of one experimental and different brands of composite resins light-cured by two light sources (one LED and one argon laser). The percentage of unreacted C = C was determined from the ratio of absorbance intensities of aliphatic C = C (peak at 1637 cm−1) against internal standards before and after curing: aromatic C–C (peak at 1610 cm−1) except for P90, where %C = C bonds was given for C–O–C (883 cm−1) and C–C (1257 cm−1). ANOVA and Tukey's test revealed no statistically significant difference among Z350 (67.17), Z250 (69.52) and experimental (66.61  ±  2.03) with LED, just among them and Evolu-X (75.51) and P90 (32.05) that showed higher and lower DC%, respectively. For the argon laser, there were no differences among Z250 (70.67), Z350 (69.60), experimental (65.66) and Evolu-X (73, 37), however a significant difference was observed for P90 (36.80), which showed lowest DC%. The light sources showed similar DC%, however the main difference was observed regarding the composite resins. The lowest DC% was observed for the argon laser. P90 showed the lowest DC% for both light-curing sources.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP

    Corrective shoeing in horses: analysis of the adaptation period to the new condition imposed

    No full text
    Corrective shoeing is a method commonly used to alter the locomotion pattern in animals or as therapy for various disorders of the locomotive system of horses. However, to date, there have been no scientific studies discussing the period during which animals adapt to this type of intervention. The goal of this study was to evaluate the horseshoe adaptation period with the toe or heel elevated by six degrees at 0, 48, and 96 hours after each type of shoeing. For this analysis, the horses were recorded while walking on a treadmill. Stride length and gait qualitative analyzes were performed using Dvideow software. The level of significance adopted was 5%. In the present study, there was no significant difference between the evaluation times; elevating the toe or heel by six degrees do not generates discomfort during locomotion, therefore, horses are able to return to a regular exercise or training routine immediately after shoeing

    Proteínas séricas de potros da raça Puro Sangue Árabe recém-desmamados ou com mais de trinta dias de desmame

    No full text
    A fase perinatal do desenvolvimento constitui um dos períodos de vida mais desafiadores para o sistema imunológico dos potros. O objetivo do presente estudo foi verificar o perfil protéico sérico de parâmetros relacionados à imunidade de equinos jovens no período perinatal, verificando-se a transferência de imunidade passiva. Oito animais desmamados há um dia, formaram o Grupo 1 (G1), enquanto vinte animais desmamados há mais de trinta dias formaram o Grupo 2 (G2). A concentração sérica de proteína total foi determinada por refratometria. Para o fracionamento das proteínas, utilizou-se eletroforese em gel de acrilamida. Os resultados obtidos foram submetidos à análise de medidas repetidas e ao teste Tukey (p<0,05) para comparação das médias. As concentrações de IgA apresentaram diferença (p<0,05) entre os grupos, porém os valores observados encontravam-se dentro do considerado normal para equinos adultos. Não houve diferença (p>0,05) nas concentrações de IgG. O estabelecimento adequado da imunidade celular ocorre durante a fase neonatal, nos animais que ingerem adequadamente o colostro e o leite. O presente estudo determinou diferenças no perfil protéico sérico de parâmetros relacionados à imunidade de equinos jovens no período imediato ao desmame, comparados com animais desmamados há mais de 30 dias. De acordo com os valores observados, concluiu-se que os animais, mesmo desmamados precocemente, obtiveram transferência adequada de imunidade passiva
    corecore