33 research outputs found

    Auditory sustained field responses to periodic noise

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Auditory sustained responses have been recently suggested to reflect neural processing of speech sounds in the auditory cortex. As periodic fluctuations below the pitch range are important for speech perception, it is necessary to investigate how low frequency periodic sounds are processed in the human auditory cortex. Auditory sustained responses have been shown to be sensitive to temporal regularity but the relationship between the amplitudes of auditory evoked sustained responses and the repetitive rates of auditory inputs remains elusive. As the temporal and spectral features of sounds enhance different components of sustained responses, previous studies with click trains and vowel stimuli presented diverging results. In order to investigate the effect of repetition rate on cortical responses, we analyzed the auditory sustained fields evoked by periodic and aperiodic noises using magnetoencephalography.</p> <p>Results</p> <p>Sustained fields were elicited by white noise and repeating frozen noise stimuli with repetition rates of 5-, 10-, 50-, 200- and 500 Hz. The sustained field amplitudes were significantly larger for all the periodic stimuli than for white noise. Although the sustained field amplitudes showed a rising and falling pattern within the repetition rate range, the response amplitudes to 5 Hz repetition rate were significantly larger than to 500 Hz.</p> <p>Conclusions</p> <p>The enhanced sustained field responses to periodic noises show that cortical sensitivity to periodic sounds is maintained for a wide range of repetition rates. Persistence of periodicity sensitivity below the pitch range suggests that in addition to processing the fundamental frequency of voice, sustained field generators can also resolve low frequency temporal modulations in speech envelope.</p

    Repetitive Passive Finger Movement Modulates Primary Somatosensory Cortex Excitability

    Get PDF
    Somatosensory inputs induced by repetitive passive movement (RPM) modulate primary motor cortex (M1) excitability; however, it is unclear whether RPM affects primary somatosensory cortex (S1) excitability. In this study, we investigated whether RPM affects somatosensory evoked potentials (SEPs) and resting state brain oscillation, including alpha and beta bands, depend on RPM frequency. Nineteen healthy subjects participated in this study, and SEPs elicited by peripheral nerve electrical stimulation were recorded from the C3’ area in order to assess S1 excitability (Exp. 1: n = 15). We focused on prominent SEP components such as N20, P25 and P45-reflecting S1 activities. In addition, resting electroencephalograms (EEGs) were recorded from C3’ area to assess the internal state of the brain network at rest (Exp. 2: n = 15). Passive abduction/adduction of the right index finger was applied for 10 min at frequencies of 0.5, 1.0, 3.0, and 5.0 Hz in Exp. 1, and 1.0, 3.0, and 5.0 Hz in Exp. 2. No changes in N20 or P25 components were observed following RPM. The 3.0 Hz-RPM decreased the P45 component for 20 min (p &lt; 0.05), but otherwise did not affect the P45 component. There was no difference in the alpha and beta bands before and after any RPM; however, a negative correlation was observed between the rate of change of beta power and P45 component at 3.0 Hz-RPM. Our findings indicated that the P45 component changes depending on the RPM frequency, suggesting that somatosensory inputs induced by RPM influences S1 excitability. Additionally, beta power enhancement appears to contribute to the P45 component depression in 3.0 Hz-RPM

    Repetitive Passive Movement Modulates Corticospinal Excitability: Effect of Movement and Rest Cycles and Subject Attention

    Get PDF
    Repetitive passive movement (PM) affects corticospinal excitability; however, it is unknown whether a duty cycle which repeats movement and rest, or subjects’ conscious attention to movements, affects corticospinal excitability. We aimed to clarify the effect of the presence or absence of a duty cycle and subjects’ attention on corticospinal excitability. Three experiments were conducted. In Experiment 1, PM of the right index finger was performed for 10 min. Three conditions were used: (1) continuous PM (cPM) at a rate of 40°/s; (2) intermittent PM (iPM) with a duty cycle at 40°/s; and (3) iPM at 100°/s. In conditions 1 and 3, motor evoked potential (MEP) amplitude was significantly reduced. In Experiment 2, PM was performed for 30 min: condition 1 comprised cPM at a rate of 40°/s and Condition 2 comprised iPM at 40°/s. MEP amplitude significantly decreased in both conditions. In Experiment 3, PM was performed for 10 min: condition 1 comprised paying attention to the moving finger during iPM and Condition 2 was similar to Condition 1 but while counting images on a monitor without looking at the movement finger, and Condition 3 comprised counting images on a monitor without performing PM. MEP amplitude significantly increased only under Condition 1. Thus, afferent input from movements above a certain threshold may affect corticospinal excitability reduction. Furthermore, corticospinal excitability increases when paying attention to passive finger movement

    Echoic memory of a single pure tone indexed by change-related brain activity

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The rapid detection of sensory change is important to survival. The process should relate closely to memory since it requires that the brain separate a new stimulus from an ongoing background or past event. Given that sensory memory monitors current sensory status and works to pick-up changes in real-time, any change detected by this system should evoke a change-related cortical response. To test this hypothesis, we examined whether the single presentation of a sound is enough to elicit a change-related cortical response, and therefore, shape a memory trace enough to separate a subsequent stimulus.</p> <p>Results</p> <p>Under a paradigm where two pure sounds 300 ms in duration and 800 or 840 Hz in frequency were presented in a specific order at an even probability, cortical responses to each sound were measured with magnetoencephalograms. Sounds were grouped to five events regardless of their frequency, 1D, 2D, and 3D (a sound preceded by one, two, or three different sounds), and 1S and 2S (a sound preceded by one or two same sounds). Whereas activation in the planum temporale did not differ among events, activation in the superior temporal gyrus (STG) was clearly greater for the different events (1D, 2D, 3D) than the same event (1S and 2S).</p> <p>Conclusions</p> <p>One presentation of a sound is enough to shape a memory trace for comparison with a subsequent physically different sound and elicits change-related cortical responses in the STG. The STG works as a real-time sensory gate open to a new event.</p

    Non-linear laws of echoic memory and auditory change detection in humans

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The detection of any abrupt change in the environment is important to survival. Since memory of preceding sensory conditions is necessary for detecting changes, such a change-detection system relates closely to the memory system. Here we used an auditory change-related N1 subcomponent (change-N1) of event-related brain potentials to investigate cortical mechanisms underlying change detection and echoic memory.</p> <p>Results</p> <p>Change-N1 was elicited by a simple paradigm with two tones, a standard followed by a deviant, while subjects watched a silent movie. The amplitude of change-N1 elicited by a fixed sound pressure deviance (70 dB vs. 75 dB) was negatively correlated with the logarithm of the interval between the standard sound and deviant sound (1, 10, 100, or 1000 ms), while positively correlated with the logarithm of the duration of the standard sound (25, 100, 500, or 1000 ms). The amplitude of change-N1 elicited by a deviance in sound pressure, sound frequency, and sound location was correlated with the logarithm of the magnitude of physical differences between the standard and deviant sounds.</p> <p>Conclusions</p> <p>The present findings suggest that temporal representation of echoic memory is non-linear and Weber-Fechner law holds for the automatic cortical response to sound changes within a suprathreshold range. Since the present results show that the behavior of echoic memory can be understood through change-N1, change-N1 would be a useful tool to investigate memory systems.</p

    Does Long-Term Training in a Water Immersion Environment Change Interoception?

    No full text
    The aim of this study was to investigate individual interoception by comparing the responses of swimmers and baseball players when exposed to specific water environments, depending on training content and environment. Forty-eight healthy male university students were evaluated for their interoceptive response (accuracy, sensibility, and awareness) and heart rate following 25 min of water immersion (WI) at 35 °C. We assessed three conditions: pre-WI, during WI, and post-WI. The results indicated that interoceptive accuracy (IAcc) did not differ between groups because both swimming and baseball do not require emotional expression, as opposed to an activity such as dance. The heart rate was significantly decreased at post-WI compared to that at pre-WI. The IAcc of post-WI presented as higher than that of pre-WI. In addition, there was a significant negative correlation between the ratio of IAcc and that of HR among subjects. Moreover, the attention regulation subscale of the MAIA changed in the WI environment and the ratio of IAcc was negatively correlated with that of the not-distracting subscale of the MAIA. These results suggested that interoception did not differ among the athletes who had long-term training, which enabled them to acquire multi-modal sensorimotor integration, compared to that of non-athlete control participants. We conclude that interoception did not differ among athletes who had long-term training compared to that of non-athlete control participants

    Interoceptive accuracy is related to the psychological mechanisms of the burning mouth syndrome: a cross-sectional study

    No full text
    Abstract Background Different perspectives are needed to understand the pathophysiology of burning mouth syndrome (BMS), including physiological and psychological standpoints. The significance of interoception in chronic pain has been suggested. However, few studies have investigated this relationship in BMS. Therefore, we examined the role of interoception in BMS. Methods This is a cross-sectional study. BMS patients (N = 64) participated in the study. We used interoceptive accuracy (IAc) based on the heartbeat counting task. Then, participants were divided into high and low IAc groups, and their scores on clinical assessment including pain and psychological evaluation were compared. Results The Visual Analogue Scale scores indicating pain in low IAc patients, but not high IAc patients, were positively correlated with the Beck Depression Inventory-Second Edition (BDI-II) and the State-Trait Anxiety Inventory-State (STAI-S) Scores. Conclusions Interoception might play a role in the pathophysiology of BMS
    corecore