106 research outputs found

    7 T MRI of the Cervical Neuroforamen: Assessment of Nerve Root Compression and Dorsal Root Ganglia in Patients With Radiculopathy

    Get PDF
    OBJECTIVES: The aim of this study was to assess the diagnostic value of 3-dimensional dual-echo steady-state (DESS) magnetic resonance imaging (MRI) of the cervical spine at 7 T compared with 3 T in patients with cervical radiculopathy. MATERIALS AND METHODS: Patients diagnosed with cervical radiculopathy were prospectively recruited between March 2020 and January 2023 before undergoing surgical decompression and received 3-dimensional DESS imaging at 3 T and 7 T MRI. Cervical nerve root compression and the dimensions of the dorsal root ganglia were assessed by 2 radiologists independently. Signal intensity, visibility of nerve anatomy, diagnostic confidence, and image artifacts were evaluated with Likert scales. The degree of neuroforaminal stenosis was assessed on standard clinical 3 T scans. Statistics included the analysis of the diagnostic accuracy and interreader reliability. The Wilcoxon signed rank test was used to assess differences between the groups. RESULTS: Forty-eight patients (mean age, 57 ± 12 years; 22 women) were included in the study with the highest prevalence of severe neuroforaminal stenosis observed at C6 (n = 68) followed by C7 (n = 43). Direct evaluation of nerve root compression showed significantly higher diagnostic confidence and visibility of cervical nerve rootlets, roots, and dorsal root ganglia on 7 T DESS than on 3 T DESS (diagnostic confidence: P = 0.01, visibility: P < 0.01). Assessment of nerve root compression using 7 T DESS allowed more sensitive grading than standard clinical MRI (P < 0.01) and improved the performance in predicting sensory or motor dysfunction (area under the curve combined: 0.87). CONCLUSIONS: 7 T DESS imaging allows direct assessment of cervical nerve root compression in patients with radiculopathy, with a better prediction of sensory or motor dysfunction than standard clinical MRI. Diagnostic confidence and image quality of 7 T DESS were superior to 3 T DESS

    The protein and contrast agent-specific influence of pathological plasma-protein concentration levels on contrast-enhanced magnetic resonance imaging

    Full text link
    OBJECTIVE: The objective of this study was to measure the protein-specific response of r1 and r2 relaxivities of commercially available gadolinium-based magnetic resonance imaging contrast agents to variation of plasma-protein concentrations. MATERIALS AND METHODS: In this in vitro study, contrast agent (gadofosveset trisodium, gadoxetate disodium, gadobutrol, and gadoterate meglumine) dilution series (0-2.5 mmol Gd/L) were prepared with plasma-protein (human serum albumin [HSA] and immunoglobulin G [IgG]) concentrations at physiological (42 and 10 g/L HSA and IgG, respectively, Normal) and at 3 pathological levels with HSA/IgG concentrations of 10/10 (solution Alb low), 42/50 (IgG mild), and 42/70 (IgG severe) g/L. Contrast-agent molar relaxivities and relaxivity-enhancing protein-contrast-agent interaction coefficients were determined on the basis of inversion-recovery and spin-echo data acquired at 1.5 and 3.0 T at 37°C. Protein-induced magnetic resonance imaging signal changes were calculated. RESULTS: The effective r1 and r2 molar relaxivities consistently increased with albumin and IgG concentrations. At 1.5 T, the r1 values increased by 10.2 (gadofosveset), 4.3 (gadoxetate), 1.3 (gadobutrol), and 1.1 L s mmol (gadoterate), respectively, from the Alb low to the IgG severe solution. At 3.0 T, the r1 values increased by 2.9 (gadofosveset), 2.3 (gadoxetate), 0.7 (gadobutrol), and 0.9 (gadoterate) L s mmol, respectively. An excess of IgG most strongly increased the r1 of gadoxetate (+40 and +19% at 1.5 and 3.0 T, respectively, from Normal to IgG severe). An albumin deficiency most strongly decreased the r1 of gadofosveset (-44% and -20% at 1.5 and 3.0 T, respectively, from Normal to Alb low). The modeling confirmed a strong gadofosveset r1 enhancement by albumin and suggested stronger IgG than albumin effects on the apparent molar relaxivity of the other agents per protein mass concentration at 1.5 T. CONCLUSIONS: Pathological deviations from normal plasma-protein concentrations in aqueous solutions result in changes of effective r1 and r2 contrast-agent relaxivities and projected signal enhancements that depend on the contrast agent, the blood-serum protein profile, and the field strength

    Probabilistic Mobility Models for Mobile and Wireless Networks

    Get PDF
    International audienceIn this paper we present a probabilistic broadcast calculus for mobile and wireless networks whose connections are unreliable. In our calculus, broadcasted messages can be lost with a certain probability, and due to mobility the connection probabilities may change. If a network broadcasts a message from a location, it will evolve to a network distribution depending on whether nodes at other locations receive the message or not. Mobility of nodes is not arbitrary but guarded by a probabilistic mobility function (PMF), and we also define the notion of a weak bisimulation given a PMF. It is possible to have weak bisimular networks which have different probabilistic connectivity information. We furthermore examine the relation between our weak bisimulation and a minor variant of PCTL* [1]. Finally, we apply our calculus on a small example called the Zeroconf protocol [2]

    Parameterized Verification of Safety Properties in Ad Hoc Network Protocols

    Full text link
    We summarize the main results proved in recent work on the parameterized verification of safety properties for ad hoc network protocols. We consider a model in which the communication topology of a network is represented as a graph. Nodes represent states of individual processes. Adjacent nodes represent single-hop neighbors. Processes are finite state automata that communicate via selective broadcast messages. Reception of a broadcast is restricted to single-hop neighbors. For this model we consider a decision problem that can be expressed as the verification of the existence of an initial topology in which the execution of the protocol can lead to a configuration with at least one node in a certain state. The decision problem is parametric both on the size and on the form of the communication topology of the initial configurations. We draw a complete picture of the decidability and complexity boundaries of this problem according to various assumptions on the possible topologies.Comment: In Proceedings PACO 2011, arXiv:1108.145

    The light verb constructions in Japanese

    No full text
    We study the light verb constructions in Japanese, the constructions of verb phrases with 'suru'. We analyse and describe systematically the phenomena and propose how to encode the meaning in Verbmobil Interface Term (VIT). We also compare the constructions with those in German and English. (orig.)SIGLEAvailable from TIB Hannover: RR 5221(221)+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman

    Assessment of aortoiliac and renal arteries: MR angiography with parallel acquisition versus conventional MR angiography and digital subtraction angiography

    Full text link
    PURPOSE: To prospectively compare the image quality, sensitivity, and specificity of three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography accelerated by parallel acquisition (ie, fast MR angiography) with MR angiography not accelerated by parallel acquisition (ie, conventional MR angiography) for assessment of aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was obtained from all patients. Forty consecutive patients (33 men, seven women; mean age, 63 years) suspected of having aortoiliac and renal arterial stenoses and thus examined with DSA underwent both fast (mean imaging time, 17 seconds) and conventional (mean imaging time, 29 seconds) MR angiography. The arterial tree was divided into segments for image analysis. Two readers independently evaluated all MR angiograms for image quality, presence of arterial stenosis, and renal arterial variants. Image quality, sensitivity, and specificity were analyzed on per-patient and per-segment bases for multiple comparisons (with Bonferroni correction) and for dependencies between segments (with patient as the primary sample unit). Interobserver agreement was evaluated by using kappa statistics. RESULTS: Overall, the image quality with fast MR angiography was significantly better (P=.001) than that with conventional MR angiography. At per-segment analysis, the image quality of fast MR angiograms of the distal renal artery tended to be better than that of conventional MR angiograms of these vessels. Differences in sensitivity for the detection of arterial stenosis between the two MR angiography techniques were not significant for either reader. Interobserver agreement in the detection of variant renal artery anatomy was excellent with both conventional and fast MR angiography (kappa=1.00). CONCLUSION: Fast MR angiography and conventional MR angiography do not differ significantly in terms of arterial stenosis grading or renal arterial variant detection

    A study in transfer Japanese-English

    No full text
    SIGLEAvailable from TIB Hannover: RR 5221(101)+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman
    corecore