783 research outputs found
Status of Neutrino Masses and Mixing and Future Perspectives
Status of the problem of neutrino masses, mixing and oscillations is
discussed. Future perspectives are briefly considered.Comment: Report at the conference IRGAC 2006, Barcelona July 11-15 200
Proper-time Resolution Function for Measurement of Time Evolution of B Mesons at the KEK B-Factory
The proper-time resolution function for the measurement of the time evolution
of B mesons with the Belle detector at KEKB is studied in detail. The obtained
resolution function is applied to the measurement of B meson lifetimes, the
B0-B0bar oscillation frequency and time-dependent CP asymmetries.Comment: 25 pages, 18 figures, to be published in NIM A, replaced with revised
versio
Methyl Mercury Exposure at Niigata, Japan: Results of Neurological Examinations of 103 Adults
Background. Large-scale poisonings caused by methyl mercury (MeHg) have occurred in Japan (Minamata in the 1950s and Niigata in the 1960s) and Iraq (in the 1970s). The current WHO neurological risk standard for adult exposure (hair level: 50 μg/g) was based partly on evidence from Niigata which did not consider any cases who were diagnosed later and/or exposed to low level of MeHg (hair mercury level less than 50 μg/g). Methods. Early in the Niigata epidemic in June 1965 there were two extensive surveys. From these two surveys, we examined 103 adults with hair mercury measurement who consulted two medical institutions. We compared the prevalence and the distribution of neurological signs related to MeHg poisoning between exposure categories. Result. We found 48 subjects with neurological signs related to MeHg poisoning who had hair mercury concentration less than 50 μg/g. Among the neurological signs, sensory disturbance of the bilateral distal extremities was observed more frequently, followed by disequilibrium, hearing impairment, and ataxia, in groups with hair MeHg concentration both below 50 μg/g and over 50 μg/g. Conclusion. The present study suggests the possibility that exposure to MeHg at levels below the current WHO limits could cause neurologic signs, in particular, sensory disturbance
Application of Hamamatsu MPPC to T2K Neutrino Detectors
A special type of Hamamatsu MPPC, with a sensitive area of 1.3x1.3mm^2
containing 667 pixels with 50x50um^2 each, has been developed for the near
neutrino detector in the T2K long baseline neutrino experiment. About 60 000
MPPCs will be used in total to read out the plastic scintillator detectors with
wavelength shifting fibers. We report on the basic performance of MPPCs
produced for T2K.Comment: Contribution to the proceedings of NDIP 2008, Aix-les-Bains, France,
June 15-20, 200
A new design for the CERN-Fr\'ejus neutrino Super Beam
We present an optimization of the hadron focusing system for a low-energy
high-intensity conventional neutrino beam (Super-Beam) proposed on the basis of
the HP-SPL at CERN with a beam power of 4 MW and an energy of 4.5 GeV. The far
detector would be a 440 kton Water Cherenkov detector (MEMPHYS) located at a
baseline of 130 km in the Fr\'ejus site. The neutrino fluxes simulation relies
on a new GEANT4 based simulation coupled with an optimization algorithm based
on the maximization of the sensitivity limit on the mixing angle.
A new configuration adopting a multiple horn system with solid targets is
proposed which improves the sensitivity to and the CP violating
phase .Comment: 11 pages, 18 figures, 2 table
Performance of Multi-Pixel Photon Counters for the T2K near detectors
We have developed a Multi-Pixel Photon Counter (MPPC) for the neutrino
detectors of T2K experiment. About 64,000 MPPCs have been produced and tested
in about a year. In order to characterize a large number of MPPCs, we have
developed a system that simultaneously measures 64 MPPCs with various bias
voltage and temperature. The performance of MPPCs are found to satisfy the
requirement of T2K experiment. In this paper, we present the performance of
17,686 MPPCs measured at Kyoto University.Comment: 15 pages, 14 figure
- …