4 research outputs found

    Bench-Scale Fixed-Bed Column Study for the Removal of Dye-Contaminated Effluent Using Sewage-Sludge-Based Biochar

    Get PDF
    Batik industrial effluent wastewater (BIE) contains toxic dyes that, if directly channeled into receiving water bodies without proper treatment, could pollute the aquatic ecosystem and, detrimentally, affect the health of people. This study is aimed at assessing the adsorptive efficacy of a novel low-cost sewage-sludge-based biochar (SSB), in removing color from batik industrial effluent (BIE). Sewage-sludge-based biochar (SSB) was synthesized through two stages, the first is raw-material gathering and preparation. The second stage is carbonization, in a muffle furnace, at 700 ◦C for 60 min. To investigate the changes introduced by the preparation process, the raw sewage sludge (RS) and SSB were characterized by the Brunauer–Emmett–Teller (BET) method, Fourier-transform infrared spectroscopy (FTIR), and scanning electron microscopy. The surface area of biochar was found to be 117.7 m2/g. The results of FTIR showed that some functional groups, such as CO and OH, were hosted on the surface of the biochar. Continuous fixed-bed column studies were conducted, by using SSB as an adsorbent. A glass column with a diameter of 20 mm was packed with SSB, to depths of 5 cm, 8 cm, and 12 cm. The volumes of BIE passing through the column were 384 mL/d, 864 mL/d, and 1680 mL/d, at a flow rate of 16 mL/h, 36 mL/h, and 70 mL/h, respectively. The initial color concentration in the batik sample was 234 Pt-Co, and the pH was kept in the range of 3–5. The effect of varying bed depth and flow rate over time on the removal efficiency of color was analyzed. It was observed that the breakthrough time differed according to the depth of the bed and changes in the flow rates. The longest time, where breakthrough and exhausting points occurred, was recorded at the highest bed and slowest flowrate. However, the increase in flow rate and decrease in bed depth made the breakthrough curves steeper. The maximum bed capacity of 42.30 mg/g was achieved at a 16 mL/h flowrate and 12 cm bed height. Thomas and Bohart–Adams mathematical models were applied, to analyze the adsorption data and the interaction between the adsorption variables. For both models, the correlation coefficient (R 2 ) was more than 0.9, which signifies that the experimental data are well fitted. Furthermore, the adsorption behavior is best explained by the Thomas model, as it covers the whole range of breakthrough curves

    Adsorption of Cooper and Cadmium From Aqueous Solutions Using Sulfurized Activated Carbon Derived From Sewage Sludge

    No full text
    The excessive existence of heavy metals in nature is very dangerous. Many methods are used to remove heavy metals, such as precipitation and ion exchange but they have many drawbacks such as high cost and time consuming. Adsorption using sludge-based adsorbent is a promising and cheap technique to remove heavy metals and help in handling the annual increasing of sludge volume. In this study, sewage sludge based sulfurized activated carbon (SAC) was prepared and investigated for Copper and Cadmium removal in batch and column studies

    Sustainable sewage sludge biosorbent activated carbon for remediation of heavy metals: Optimization by response surface methodology

    No full text
    This study investigated the potential use of sewage sludge-based activated carbon in the removal of copper (Cu) and cadmium (Cd) ions from aqueous solutions. The activated carbon (AC) was prepared by chemical activation using potassium hydroxide KOH and heating in a tube furnace at 600 °C for 2 h. The produced activated carbon was further subject to a sulfurization process to enhance its removal efficiency. The study used Box-Behnken Design (BBD) in response surface methodology (RSM) to optimize several parameters, including initial metal concentration, activated carbon dose, pH, and contact time. Results showed that the sulfurization process introduced sulfur functional groups (SO) to the surface of the activated carbon and decreased its specific area from 190 to 173 m2/g. The quadratic model was suggested as the best model to describe the effect of the adsorption parameters on the removal percentage with high R2 values (≥0.9) and p-value less than 0.05. Second-order polynomial equations, analysis of variance (ANOVA), and three-dimensional surface plots were developed to assess the interaction between the parameters and the optimal conditions to remove copper and cadmium ions. The optimum removal parameters for copper ions were 300 min, 100 ppm initial concentration, 20 g/L activated carbon dose, and pH 6, with a removal efficiency of 83.9%. Cadmium removal of 87.5% was achieved at 11 ppm, 300 minutes contact time, pH 6, and 2.5 g/L adsorbent dose. The activated carbon capacity in removing copper and cadmium was 16 mg/g and 17.6 mg/g respectively. The sulfurization process increased the removal percentage for copper and cadmium ions by 14.5 and 18.7% respectively. Advanced analytical techniques such as FITR, SEM-EDX, BET surface area, and elemental analysis were used to characterize the materials

    Adsorptive Removal of Boron by DIAION™ CRB05: Characterization, Kinetics, Isotherm, and Optimization by Response Surface Methodology

    No full text
    A significant issue for the ecosystem is the presence of boron in water resources, particularly in produced water. Batch and dynamic experiments were used in this research to extract boron in the form of boric acid from aqueous solutions using boron selective resins, DIAION CRB05. DIAION™ CRB05 is an adsorbent that is effective in extracting boron from aqueous solutions due to its high binding capacity and selectivity for boron ions, and it is also regenerable, making it cost-effective and sustainable. Field Emission Scanning Electron Microscopy (FESEM), X-ray diffraction (XRD), and FTIR analysis for DIAION CRB05 characterization. To increase the adsorption capacity and find the ideal values for predictor variables such as pH, adsorbent dose, time, and boric acid concentration, the Box–Behnken response surface method (RSM) was applied. The dosage was reported to be 2000 mg/L at pH 2 and boron initial concentration of 1115 mg/L with 255 min for the highest removal anticipated from RSM. According to the outcomes of this research, the DIAION CRB05 material enhanced boron removal capability and has superior performance to several currently available adsorbents, which makes it suitable for use as an adsorbent for removing boric acid from aqueous solutions. The outcomes of isotherm and kinetic experiments were fitted using linear methods. The Temkin isotherm and the pseudo-first-order model were found to have good fits after comparison with R2 of 0.998, and 0.997, respectively. The results of the study demonstrate the effectiveness of DIAION™ CRB05 in removing boron from aqueous solutions and provide insight into the optimal conditions for the adsorption process. Thus, the DIAION CRB05 resin was chosen as the ideal choice for recovering boron from an aqueous solution because of its higher sorption capacity and percentage of boron absorbed
    corecore