4 research outputs found

    Comparison of cerebral cortex activation induced by tactile stimulation between natural teeth and implants

    Get PDF
    The purpose of this study was to assess the cortical-level sensory differences between natural teeth with a periodontal membrane and dental implants. We used functional near-infrared spectroscopy (fNIRS) to measure brain activity in the cerebral cortex of 12 patients who had both natural teeth and dental implants in the lower molar region. Painless vibratory tactile stimulation was performed on both the natural teeth and the dental implants. Activation was seen in the somatosensory cortex during stimulation of both natural teeth and dental implants. A comparison of cortical activation showed no significant differences between natural teeth and dental implants. These results indicate the possible existence of sensory input to the cerebral cortex via dental implants as well as natural teeth, and thus suggest that may not only the periodontal membrane be involved in the signaling pathway. The data from this experiment may help us for understanding the neural mechanisms underlying natural teeth and dental implants

    Accuracy of Dental Models Fabricated Using Recycled Poly-Lactic Acid

    No full text
    Based on the hypothesis that the fabrication of dental models using fused deposition modeling and poly-lactic acid (PLA), followed by recycling and reusing, would reduce industrial waste, we aimed to compare the accuracies of virgin and recycled PLA models. The PLA models were recycled using a crusher and a filament-manufacturing machine. Virgin PLA was labeled R, and the first, second, and third recycles were labeled R1, R2, and R3, respectively. To determine the accuracies of the virgin and reused PLA models, identical provisional crowns were fitted, and marginal fits were obtained using micro-computed tomography. A marginal fit of 120 µm was deemed acceptable based on previous literature. The mesial, distal, buccal, and palatal centers were set at M, D, B, and P, respectively. The mean value of each measurement point was considered as the result. When comparing the accuracies of R and R1, R2, and R3, significant differences were noted between R and R3 at B, R and R2, R3 at P, and R and R3 at D (p < 0.05). No significant difference was observed at M. This study demonstrates that PLA can be recycled only once owing to accuracy limitations

    Verification of the accuracy of dynamic navigation for conventional and mouthpiece methods: in vivo study

    No full text
    Abstract Background Dynamic navigation for implant placement is becoming popular under the concept of top-down treatment. The purpose of this study is to verify the accuracy of a dynamic navigation system for implant placement. Methods Implant placement was performed on 38 patients using 50 implant fixtures. Patients in group C were treated using a conventional method, in which thermoplastic clips were fixed to the teeth, and patients in group M were treated using thermoplastic clips fixed to a mouthpiece attached to the teeth. The groups were compared to verify whether an accuracy difference existed. A treatment planning support program for dental implants was used to superimpose the postoperative computed tomography data on the preoperative implant design data to measure the entry point, apex point, and angular deviation. Results The accuracy of group C was 1.36 ± 0.51 mm for entry point, 1.30 ± 0.59 mm for apex point, and 3.20 ± 0.74° for angular deviation. The accuracy of group M was 1.06 ± 0.31 mm for the entry point, 1.02 ± 0.30 mm for the apex point, and 2.91 ± 0.97° for angular deviation. Significant differences were observed in the entry and apex points between the two groups. Conclusions The results indicate that group M exhibited better accuracy than group C, indicating that the stability of the thermoplastic clip is important for ensuring the accuracy of the dynamic navigation system. No previous studies have verified the accuracy of this system using the mouthpiece method, and additional data is required to confirm its accuracy for dental implant placement. The mouthpiece method improves the accuracy of implant placement and provides a safer implant treatment than the conventional method. Trial registration University hospital Medical Information Network Clinical Trials Registry (UMIN-CTR), Registration Number: UMIN000051949, URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view_his.cgi on August 21, 2023
    corecore