53 research outputs found

    Agglomerated novel spray-dried lactose-leucine tailored as a carrier to enhance the aerosolization performance of salbutamol sulfate from DPI formulations

    Get PDF
    Spray-drying allows to modify the physicochemical/mechanical properties of particles along with their morphology. In the present study, L-leucine with varying concentrations (0.1, 0.5, 1, 5, and 10% w/v) were incorporated into lactose monohydrate solution for spray-drying to enhance the aerosolization performance of dry powder inhalers containing spray-dried lactose-leucine and salbutamol sulfate. The prepared spray-dried lactose-leucine carriers were analyzed using laser diffraction (particle size), differential scanning calorimetry (thermal behavior), scanning electron microscopy (morphology), powder X-ray diffraction (crystallinity), Fourier transform infrared spectroscopy (interaction at molecular level), and in vitro aerosolization performance (deposition). The results showed that the efficacy of salbutamol sulfate’s aerosolization performance was, in part, due to the introduction of L-leucine in the carrier, prior to being spray-dried, accounting for an increase in the fine particle fraction (FPF) of salbutamol sulfate from spray-dried lactose-leucine (0.5% leucine) in comparison to all other carriers. It was shown that all of the spray-dried carriers were spherical in their morphology with some agglomerates and contained a mixture of amorphous, α-lactose, and β-lactose. It was also interesting to note that spray-dried lactose-leucine particles were agglomerated during the spray-drying process to make coarse particles (volume mean diameter of 79 to 87 μm) suitable as a carrier in DPI formulations

    Fundamentals of aerosol therapy in critical care

    Full text link

    Performance Characteristics of Breezhaler((R)) and Aerolizer((R)) in the Real-World Setting

    Get PDF
    The evaluation of errors in use with different inhaler devices is challenging to quantify as there are a number of definitions of critical and non-critical errors with respect to inhaler use; in addition, performance characteristics of the device, such as airflow resistance, can also influence effective use in the real-world setting. Repeated observations and checking/correcting inhaler use are essential to optimise clinical effectiveness of inhaled therapy in patients. Breezhaler® is a single unit-dose dry powder inhaler used in chronic obstructive pulmonary disease and in asthma (budesonide) that has low airflow resistance, making it easier for patients of varying disease severities to achieve the inhalation flow rate required for lung deposition of treatment. Similar to Breezhaler®, the Aerolizer® is a single unit-dose dry powder inhaler used in asthma management with low airflow resistance. Studies have shown relatively low rates of critical errors with Breezhaler® and Aerolizer®, with similarities in the critical errors reported; these data on critical errors together with similarities in the usability of Breezhaler® and Aerolizer® further support the functional similarity between the two devices in both asthma and chronic obstructive pulmonary disease. Breezhaler® also has patient-feedback features, including use of a transparent drug capsule that can be checked after inhalation to see it is empty. The low resistance of the dose-confirming Breezhaler® results in less inspiratory effort being required by patients for its effective use, which allows the device to be used effectively across a wide age range of patients and disease severities

    Creation of a Pulmonary Model To Aid in Small Animal Imaging.

    No full text

    Cell distribution and cytokine levels in induced sputum from healthy subjects and patients with asthma after using different nebulizer techniques

    No full text
    Abstract Background Sputum induction is an important noninvasive method for analyzing bronchial inflammation in patients with asthma and other respiratory diseases. Most frequently, ultrasonic nebulizers are used for sputum induction, but breath-controlled nebulizers may target the small airways more efficiently. This treatment may produce a cell distribution similar to bronchoalveolar lavage (less neutrophils and more macrophages) and provide deeper insights into the underlying lung pathology. The goal of the study was to compare both types of nebulizer devices and their efficacy in inducing sputum to measure bronchial inflammation, i.e., cell composition and cytokines, in patients with mild allergic asthma and healthy controls. Methods The population of this study consisted of 20 healthy control subjects with a median age of 17 years, range: 8–25 years, and 20 patients with a median age of 12 years, range: 8–24 years, presenting with mild, controlled allergic asthma who were not administered an inhaled steroid treatment. We induced sputum in every individual using both devices on two separate days. The sputum weight, the cell composition and cytokine levels were analyzed using a cytometric bead assay (CBA) and by real-time quantitative PCR (qRT-PCR). Results We did not observe significant differences in the weight, cell distribution or cytokine levels in the sputum samples induced by both devices. In addition, the Bland-Altman correlation revealed good concordance of the cell distribution. As expected, eosinophils and IL-5 levels were significantly elevated in patients with asthma. Conclusions The hypothesis that sputum induction with a breath-controlled “smart” nebulizer is more efficient and different from an ultrasonic nebulizer was not confirmed. The Bland-Altman correlations showed good concordance when comparing the two devices. Trial registration NCT01543516 Retrospective registration date: March 5, 2012
    corecore