54 research outputs found

    ウサギ脊髄虚血モデルにおけるミノサイクリンの神経保護作用の評価

    Get PDF
    OBJECTIVE: To investigate whether postischemic administration of minocycline attenuates hind-limb motor dysfunction and gray and white matter injuries after spinal cord ischemia. DESIGN: A prospective, randomized, laboratory investigation. SETTING: Laboratory in university, single institution. PARTICIPANTS: Male New Zealand White rabbits. INTERVENTION: Spinal cord ischemia was induced by an occlusion of the infrarenal aorta for 15 minutes. The groups were administered minocycline 1 hour after reperfusion (M-1; n = 8), minocycline 3 hours after reperfusion (M-3; n = 8), saline 1 hour after reperfusion (control [C]; n = 8), or saline and no occlusion (sham; n = 4). Minocycline was administered intravenously at 10 mg/kg 6 times at 12-hour intervals until 60 hours after the initial administration. MEASUREMENT AND MAIN RESULTS: Hind-limb motor function was assessed using the Tarlov score. For histologic assessments, gray and white matter injuries were evaluated 72 hours after reperfusion using the number of normal neurons and the percentage of areas of vacuolation, respectively. Motor function 72 hours after reperfusion was significantly better in group M-1 than in group C. The number of neurons in the anterior horn was significantly larger in group M-1 than in groups M-3 or C but did not differ significantly between groups M-3 and C. No significant difference was noted in the percentage of areas of vacuolation among the ischemia groups. CONCLUSIONS: Minocycline administration beginning at 1 hour after reperfusion improved hind-limb motor dysfunction and attenuated gray matter injury in a rabbit spinal cord ischemia model.博士(医学)・乙第1314号・平成25年5月29

    Assessment of inhibition with the Go/No-Go Task

    Get PDF
    Young, Sutherland, and McCoy indicated that a Go/No-Go Task (GNG) becomes more difficult as the inter-stimulus intervals (ISIs) becomes shorter. However, is the number of commission errors under extremely short ISIs a useful metric for assessing response inhibition? This study challenges the assumption that a shorter ISI in the GNG enables better assessment of response inhibition. University students (N = 213) completed the GNG, the Conners Continuous Performance Test 3rd Edition (CCPT), and the Modified Stroop Task. The GNG comprised four blocks of 400, 600, 800, and 1000 ms ISIs, whereas the stimulus presentation was fixed at 250 ms. Consistent with Young et al., shorter ISIs in the GNG resulted in more commission errors. In the block with the shortest ISI, participants also failed more frequently in responses in go trials than in the other blocks, which appears to increase in error variance of commission errors. Consistent with this interpretation, the association between the number of commission errors in the block with 400 ms ISI and CCPT performance was weaker than those between the number of commission errors in other blocks and CCPT performance. It is concluded that using the number of commission errors in the condition with extremely short ISIs in the GNG might be inappropriate for assessing response inhibition

    Response inhibition deficits are positively associated with trait rumination, but attentional inhibition deficits are not : aggressive behaviors and interpersonal stressors as mediators

    Get PDF
    Previous findings on relationships between inhibition that is a core executive function, and trait rumination have been inconsistent. This inconsistency could be overcome by investigating the association between rumination and the two subcomponents of inhibition: response inhibition and attentional inhibition. This study examined whether and how response inhibition and attentional inhibition were related to rumination as well as worry. University students in Japan (N = 213) conducted the Go/No-Go Task and the Modified Stroop Task. They also completed self-report measures of depression, trait rumination, trait worry, stressors, and aggressive behaviors. Results indicated that response inhibition deficits were positively associated with trait rumination, and this association was mediated by increases in aggressive behaviors and interpersonal stressors. The associations between these variables remained significant even after controlling for depression level. There were no significant direct or indirect associations between attentional inhibition deficits and rumination. These results suggest that response inhibition deficits, among the subcomponents of inhibition, have an indirect positive association with rumination through interpersonal processes. Results also showed nonsignificant differences between rumination and worry in the magnitude of correlation coefficients with the two subcomponents of inhibition. Therefore, it remains unclear whether the positive association with response inhibition is unique to rumination

    Description and Discussion on DCASE 2022 Challenge Task 2: Unsupervised Anomalous Sound Detection for Machine Condition Monitoring Applying Domain Generalization Techniques

    Full text link
    We present the task description and discussion on the results of the DCASE 2022 Challenge Task 2: ``Unsupervised anomalous sound detection (ASD) for machine condition monitoring applying domain generalization techniques''. Domain shifts are a critical problem for the application of ASD systems. Because domain shifts can change the acoustic characteristics of data, a model trained in a source domain performs poorly for a target domain. In DCASE 2021 Challenge Task 2, we organized an ASD task for handling domain shifts. In this task, it was assumed that the occurrences of domain shifts are known. However, in practice, the domain of each sample may not be given, and the domain shifts can occur implicitly. In 2022 Task 2, we focus on domain generalization techniques that detects anomalies regardless of the domain shifts. Specifically, the domain of each sample is not given in the test data and only one threshold is allowed for all domains. Analysis of 81 submissions from 31 teams revealed two remarkable types of domain generalization techniques: 1) domain-mixing-based approach that obtains generalized representations and 2) domain-classification-based approach that explicitly or implicitly classifies different domains to improve detection performance for each domain.Comment: arXiv admin note: substantial text overlap with arXiv:2106.0449

    Reduced dose of PTCy followed by adjuvant alpha-galactosylceramide enhances GVL effect without sacrificing GVHD suppression

    Get PDF
    Posttransplantation cyclophosphamide (PTCy) has become a popular option for haploidentical hematopoietic stem cell transplantation (HSCT). However, personalized methods to adjust immune intensity after PTCy for each patient's condition have not been well studied. Here, we investigated the effects of reducing the dose of PTCy followed by alpha -galactosylceramide (alpha -GC), a ligand of iNKT cells, on the reciprocal balance between graft-versus-host disease (GVHD) and the graft-versus-leukemia (GVL) effect. In a murine haploidentical HSCT model, insufficient GVHD prevention after reduced-dose PTCy was efficiently compensated for by multiple administrations of alpha -GC. The ligand treatment maintained the enhanced GVL effect after reduced-dose PTCy. Phenotypic analyses revealed that donor-derived B cells presented the ligand and induced preferential skewing to the NKT2 phenotype rather than the NKT1 phenotype, which was followed by the early recovery of all T cell subsets, especially CD4(+)Foxp3(+) regulatory T cells. These studies indicate that alpha -GC administration soon after reduced-dose PTCy restores GVHD-preventing activity and maintains the GVL effect, which is enhanced by reducing the dose of PTCy. Our results provide important information for the development of a novel strategy to optimize PTCy-based transplantation, particularly in patients with a potential relapse risk

    Field experiment of 800× off-axis XR-Köhler concentrator module on a carousel tracker

    Get PDF
    This paper presents the design and preliminary experimental results of a concentrator-type photovoltaic module based on a free-form off-axis 800×XR-Köhler concentrator. The off-axis XR-Köhler concentrator is one of the advanced concentrators that perform high concentration with a large acceptance angle and excellent irradiance uniformity on a solar cell. As a result of on-sun characterization of the unglazed single-cell unit test rig, the temperature-corrected DC module efficiency was 32.2% at 25 °C without an anti-reflective (AR) coating on the secondary optics, and the acceptance angle was more than ±1.0°. In addition, the non-corrected DC efficiency of an individual cell in a glazed 8-cell unit module mounted on a carousel tracking system was measured. The individual efficiency deviated in the range of 24.3-27.4%, owing to the mirror shape and alignment errors. The resultant series-connected efficiency was approximately 25% at direct normal irradiation (DNI) of 770 W/m2

    Preliminary Design Study of the TMT Telescope Structure System: Overview

    Get PDF
    We present an overview of the preliminary design of the Telescope Structure System (STR) of Thirty Meter Telescope (TMT). NAOJ was given responsibility for the TMT STR in early 2012 and engaged Mitsubishi Electric Corporation (MELCO) to take over the preliminary design work. MELCO performed a comprehensive preliminary design study in 2012 and 2013 and the design successfully passed its Preliminary Design Review (PDR) in November 2013 and April 2014. Design optimizations were pursued to better meet the design requirements and improvements were made in the designs of many of the telescope subsystems as follows: 1. 6-legged Top End configuration to support secondary mirror (M2) in order to reduce deformation of the Top End and to keep the same 4% blockage of the full aperture as the previous STR design. 2. “Double Lower Tube” of the elevation (EL) structure to reduce the required stroke of the primary mirror (M1) actuators to compensate the primary mirror cell (M1 Cell) deformation caused during the EL angle change in accordance with the requirements. 3. M1 Segment Handling System (SHS) to be able to make removing and installing 10 Mirror Segment Assemblies per day safely and with ease over M1 area where access of personnel is extremely difficult. This requires semi-automatic sequence operation and a robotic Segment Lifting Fixture (SLF) designed based on the Compliance Control System, developed for controlling industrial robots, with a mechanism to enable precise control within the six degrees of freedom of position control. 4. CO2 snow cleaning system to clean M1 every few weeks that is similar to the mechanical system that has been used at Subaru Telescope. 5. Seismic isolation and restraint systems with respect to safety; the maximum acceleration allowed for M1, M2, tertiary mirror (M3), LGSF, and science instruments in 1,000 year return period earthquakes are defined in the requirements. The Seismic requirements apply to any EL angle, regardless of the operational status of Hydro Static Bearing (HSB) system and stow lock pins. In order to find a practical solution, design optimization study for seismic risk mitigation was carried out extensively, including the performing of dynamic response analyses of the STR system under the time dependent acceleration profile of seven major earthquakes. The work is now moving to the final design phase from April 2014 for two years

    A diagnostic marker for superficial urothelial bladder carcinoma : lack of nuclear ATBF1 (ZFHX3) by immunohistochemistry suggests malignant progression

    Get PDF
    Background: Pathological stage and grade have limited ability to predict the outcomes of superficial urothelial bladder carcinoma at initial transurethral resection (TUR). AT-motif binding factor 1 (ATBF1) is a tumor suppressive transcription factor that is normally localized to the nucleus but has been detected in the cytoplasm in several cancers. Here, we examined the diagnostic value of the intracellular localization of ATBF1 as a marker for the identification of high risk urothelial bladder carcinoma. Methods: Seven anti-ATBF1 antibodies were generated to cover the entire ATBF1 sequence. Four human influenza hemagglutinin-derived amino acid sequence-tagged expression vectors with truncated ATBF1 cDNA were constructed to map the functional domains of nuclear localization signals (NLSs) with the consensus sequence KR[X10-12]K. A total of 117 samples from initial TUR of human bladder carcinomas were analyzed. None of the patients had received chemotherapy or radiotherapy before pathological evaluation. Results: ATBF1 nuclear localization was regulated synergistically by three NLSs on ATBF1. The cytoplasmic fragments of ATBF1 lacked NLSs. Patients were divided into two groups according to positive nuclear staining of ATBF1, and significant differences in overall survival (P = 0.021) and intravesical recurrence-free survival (P = 0.013) were detected between ATBF1+ (n= 110) and ATBF1− (n=7) cases. Multivariate analysis revealed that ATBF1 staining was an independent prognostic factor for intravesical recurrence-free survival after adjusting for cellular grading and pathological staging (P = 0.008). Conclusions: Cleavage of ATBF1 leads to the cytoplasmic localization of ATBF1 fragments and downregulates nuclear ATBF1. Alterations in the subcellular localization of ATBF1 due to fragmentation of the protein are related to the malignant character of urothelial carcinoma. Pathological evaluation using anti-ATBF1 antibodies enabled the identification of highly malignant cases that had been overlooked at initial TUR. Nuclear localization of ATBF1 indicates better prognosis of urothelial carcinoma
    corecore