4 research outputs found
A method of increasing the film intrinsic robustness of radiochromic film dosimetry
The radiochromic film, which is used, in combination with a flatbed scanner has become a widely used tool for a quantitative evaluation of radiation dose in radiation therapy. One aspect of uncertainty using the radiochromic film is the magnitude of orientation effects when the orientation of the film is not kept constant during the digitization process. The aim of this note was to investigate the impact of using a combination of two crossed sheets of EBT2 film on various aspects of radiochromic film dosimetry. First the impact on the film sensitivity was studied. We also investigated the influence on orientation effects during scanning. The results show that the double crossed film combination increases the sensitivity with a factor 1.7-2.1 and practically eliminates the effects of film orientation on the optical density read-out and the lateral correction profiles
Precision measurement of radioactivity in Gamma-rays spectrometry using two HPGe detectors (BEGe-6530 and GC0818-7600SL models) comparison techniques: Application to the soil measurement.
To obtain high quality of results in gamma spectrometry, it is necessary to select the best HPGe detector for particular measurements, to calibrate energy and efficiency of gamma detector as accurate as possible. To achieve this aim, the convenient detector model and gamma source can be very useful. The purpose of this study was to evaluate the soil specific activity using two HPGe model (BEGe-6530 and GC0818-7600SL) by comparing the results of the two detectors and the technics used according to the detector type. The relative uncertainty activity concentration was calculated for 226Ra, 232Th and 40K. For broad energy germanium detector, BEGe-6530, the relative uncertainty concentration ranged from 2.85 to 3.09% with a mean of 2.99% for 226Ra, from 2.29 to 2.49% with a means of 2.36% for 232Th and from 3.47 to 22.37% with a mean of 12.52% for 40K. For GC0818-7600SL detector, it was ranged from 10.45 to 25.55% with a mean of 17.10% for 226Ra, from 2.54 to 3.56% with a means of 3.10% for 232Th and from 3.42 to 7.65% with a mean of 5.58% for 40K. The average report between GC0818-7600SL model and BEGe-6530 model was calculated and showed the mean value of 3.36. The main study was based on the following points:
•
Determination of The relative uncertainty activity concentration of 226Ra, 232Th and 40K
•
Determination of the relative uncertainty related to the radium equivalent activity to compare the performance of the two detection systems
•
Proved that the activity concentration determination in gamma spectrometry depended on the energy range emitted by a radionuclide.
This study showed that the standard deviation measurement was less important to the result realized with BEGe-6530 HPGe model. Our findings were demonstrated that the results of the Broad Energy Germanium detector were more reliable
Health risk assessment and statistical analysis of natural radioactivity in the uranium exploration area of Zabili, Chad
peer reviewedThe activity concentrations of natural radionuclides 226Ra, 232Th and 40K in 19 soil samples from Zabili uranium exploration area were measured using a low-background digital gamma-ray spectrometer equipped with broad energy germanium detector. The activity concentrations of 238U, 232Th, and 40K range from 16.5 to 1110.9 Bq.kg−1, 19.45 to 76.97 Bq.kg−1, and 3.28 to 839.5 Bq.kg−1, with their mean values of 478.0, 58.9, and 562.5, respectively. In addition, radiological hazard parameters from the activity concentrations obtained were assessed by estimating radium equivalent activity, external and internal hazard index, indoor and outdoor absorbed gamma dose rate and the corresponding annual effective dose, effective dose rate to different body organs and tissues, and excess lifetime cancer risk. Derived radiological hazard indices have been revised in accordance with relevant national and international legislation and guidelines. The radiological hazard parameter values were found to be above the relevant limit values for soils. In order to investigate the distribution of radionuclides and associated health hazard parameters in the study area, a statistical study was performed