11 research outputs found
Terahertz Security Image Quality Assessment by No-reference Model Observers
To provide the possibility of developing objective image quality assessment
(IQA) algorithms for THz security images, we constructed the THz security image
database (THSID) including a total of 181 THz security images with the
resolution of 127*380. The main distortion types in THz security images were
first analyzed for the design of subjective evaluation criteria to acquire the
mean opinion scores. Subsequently, the existing no-reference IQA algorithms,
which were 5 opinion-aware approaches viz., NFERM, GMLF, DIIVINE, BRISQUE and
BLIINDS2, and 8 opinion-unaware approaches viz., QAC, SISBLIM, NIQE, FISBLIM,
CPBD, S3 and Fish_bb, were executed for the evaluation of the THz security
image quality. The statistical results demonstrated the superiority of Fish_bb
over the other testing IQA approaches for assessing the THz image quality with
PLCC (SROCC) values of 0.8925 (-0.8706), and with RMSE value of 0.3993. The
linear regression analysis and Bland-Altman plot further verified that the
Fish__bb could substitute for the subjective IQA. Nonetheless, for the
classification of THz security images, we tended to use S3 as a criterion for
ranking THz security image grades because of the relatively low false positive
rate in classifying bad THz image quality into acceptable category (24.69%).
Interestingly, due to the specific property of THz image, the average pixel
intensity gave the best performance than the above complicated IQA algorithms,
with the PLCC, SROCC and RMSE of 0.9001, -0.8800 and 0.3857, respectively. This
study will help the users such as researchers or security staffs to obtain the
THz security images of good quality. Currently, our research group is
attempting to make this research more comprehensive.Comment: 13 pages, 8 figures, 4 table
A Deep Learning based Pipeline for Efficient Oral Cancer Screening on Whole Slide Images
Oral cancer incidence is rapidly increasing worldwide. The most important
determinant factor in cancer survival is early diagnosis. To facilitate large
scale screening, we propose a fully automated pipeline for oral cancer
detection on whole slide cytology images. The pipeline consists of fully
convolutional regression-based nucleus detection, followed by per-cell focus
selection, and CNN based classification. Our novel focus selection step
provides fast per-cell focus decisions at human-level accuracy. We demonstrate
that the pipeline provides efficient cancer classification of whole slide
cytology images, improving over previous results both in terms of accuracy and
feasibility. The complete source code is available at
https://github.com/MIDA-group/OralScreen.Comment: Accepted to ICIAR 202