6,245 research outputs found

    Stability of Salpeter Solutions

    Full text link
    In the framework of instantaneous approximations to the Bethe-Salpeter formalism for the description of bound states within quantum field theories, depending on the Lorentz structure of the Bethe-Salpeter interaction kernel the solutions of the full Salpeter equation with some confining interaction may exhibit certain instabilities, which are possibly related to the Klein paradox and signal the decay of states assumed to be bound by the confining interactions. They are observed in numerical (variational) studies of the Salpeter equation. The presumably simplest scenario allowing for the fully analytic investigation of this problem is set by the reduced Salpeter equation with harmonic-oscillator interaction. In this case, Salpeter's integral equation simplifies to either an algebraic relation or a second-order homogeneous linear ordinary differential equation, immediately accessible to standard techniques. There one may hope to be able to decide unambiguously whether this setting poses a well-defined eigenvalue problem the solutions of which correspond to stable bound states associated to real energy eigenvalues bounded from below. By analytical spectral analysis the bound-state solutions of this "harmonic-oscillator reduced Salpeter equation" can be shown to be free of such instabilities.Comment: 6 pages, 2 figures, to appear in the Proceedings of "QCD @ Work 2007", International Workshop on Quantum ChromoDynamics - Theory and Experiment, Martina Franca, Italy, 16 - 20 June 200

    The current progress of the ALICE Ring Imaging Cherenkov Detector

    Get PDF
    Recently, the last two modules (out of seven) of the ALICE High Momentum Particle Identification detector (HMPID) were assembled and tested. The full detector, after a pre-commissioning phase, has been installed in the experimental area, inside the ALICE solenoid, at the end of September 2006. In this paper we review the status of the ALICE/HMPID project and we present a summary of the series production of the CsI photo-cathodes. We describe the key features of the production procedure which ensures high quality photo-cathodes as well as the results of the quality assessment performed by means of a specially developed 2D scanner system able to produce a detailed map of the CsI photo-current over the entire photo-cathode surface. Finally we present our recent R&D efforts toward the development of a novel generation of imaging Cherenkov detectors with the aim to identify, in heavy ions collisions, hadrons up to 30 GeV/c.Comment: Presented at the Imaging-2006 Conference, Stockholm, Sweden, June 200

    Chern-Simons Field Theories with Non-semisimple Gauge Group of Symmetry

    Get PDF
    Subject of this work is a class of Chern-Simons field theories with non-semisimple gauge group, which may well be considered as the most straightforward generalization of an Abelian Chern-Simons field theory. As a matter of fact these theories, which are characterized by a non-semisimple group of gauge symmetry, have cubic interactions like those of non-abelian Chern-Simons field theories, but are free from radiative corrections. Moreover, at the tree level in the perturbative expansion,there are only two connected tree diagrams, corresponding to the propagator and to the three vertex originating from the cubic interaction terms. For such theories it is derived here a set of BRST invariant observables, which lead to metric independent amplitudes. The vacuum expectation values of these observables can be computed exactly. From their expressions it is possible to isolate the Gauss linking number and an invariant of the Milnor type, which describes the topological relations among three or more closed curves.Comment: 16 pages, 1 figure, plain LaTeX + psfig.st

    Advances in the Development of Micropattern Gaseous Detectors with Resistive Electrodes

    Full text link
    We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and spark protection property) with the high granularity and thus the good position resolution offered by microelectronic technology. In the stream of this activity, we have recently developed two novel detectors with resistive electrodes: one was based on resistive micromeshes and the second one is a MSGC with resistive electrodes. We have demonstrated that the resistive meshes are a convenient construction element for various designs of spark protective detectors: RPCs type, GEM type and MICROMEGAS type. These new detectors enable to considerably enhance the RPC and micropattern detectors applications since they feature not only a high position resolution but also a relatively good energy resolution (25-30 persent FWHM at 6 keV) and, if necessary, they can operate in cascaded mode allowing the achievement of a high overall gas gain. The main conclusion from these studies is that the implementation of resistive electrodes in micropattern detectors makes them fully spark protected; on this basis we consider this direction very promising

    Bibliometric Evaluation vs. Informed Peer Review: Evidence from Italy

    Get PDF
    A relevant question for the organization of large scale research assessments is whether bibliometric evaluation and informed peer review where reviewers know where the work was published, yield similar results. It would suggest, for instance, that less costly bibliometric evaluation might - at least partly - replace informed peer review, or that bibliometric evaluation could reliably monitor research in between assessment exercises. We draw on our experience of evaluating Italian research in Economics, Business and Statistics, where almost 12,000 publications dated 2004-2010 were assessed. A random sample from the available population of journal articles shows that informed peer review and bibliometric analysis produce similar evaluations of the same set of papers. Whether because of independent convergence in assessment, or the influence of bibliometric information on the community of reviewers, the implication for the organization of these exercises is that these two approaches are substitutes

    Bibliometric Evaluation vs. Informed Peer Review:Evidence from Italy

    Get PDF
    A relevant question for the organization of large scale research assessments is whether bibliometric evaluation and informed peer review where reviewers know where the work was published, yield similar results. It would suggest, for instance, that less costly bibliometric evaluation might - at least partly - replace informed peer review, or that bibliometric evaluation could reliably monitor research in between assessment exercises. We draw on our experience of evaluating Italian research in Economics, Business and Statistics, where almost 12,000 publications dated 2004-2010 were assessed. A random sample from the available population of journal articles shows that informed peer review and bibliometric analysis produce similar evaluations of the same set of papers. Whether because of independent convergence in assessment, or the influence of bibliometric information on the community of reviewers, the implication for the organization of these exercises is that these two approaches are substitutes

    Migraine and psychiatric comorbidity: a review of clinical findings.

    Get PDF
    Migraine is an extremely common disorder. The underlying mechanisms of this chronic illness interspersed with acute symptoms appear to be increasingly complex. An important aspect of migraine heterogeneity is comorbidity with other neurological diseases, cardiovascular disorders, and psychiatric illnesses. Depressive disorders are among the leading causes of disability worldwide according to WHO estimation. In this review, we have mainly considered the findings from general population studies and studies on clinical samples, in adults and children, focusing on the association between migraine and psychiatric disorders (axis I of the DSM), carried over after the first classification of IHS (1988). Though not easily comparable due to differences in methodology to reach diagnosis, general population studies generally indicate an increased risk of affective and anxiety disorders in patients with migraine, compared to non-migrainous subjects. There would also be a trend towards an association of migraine with bipolar disorder, but not with substance abuse/dependence. With respect to migraine subtypes, comorbidity mainly involves migraine with aura. Patients suffering from migraine, however, show a decreased risk of developing affective and anxiety disorders compared to patients with daily chronic headache. It would also appear that psychiatric disorders prevail in patients with chronic headache and substance use than in patients with simple migraine. The mechanisms underlying migraine psychiatric comorbidity are presently poorly understood, but this topic remains a priority for future research. Psychiatric comorbidity indeed affects migraine evolution, may lead to chronic substance use, and may change treatment strategies, eventually modifying the outcome of this important disorder

    Meeting patient expectations in migraine treatment: what are the key endpoints?

    Get PDF
    Clinical outcomes of migraine treatment are generally based on two major endpoints: acute pain resolution and effects on quality of life (QOL). Resolution of acute pain can be evaluated in a number of ways, each increasingly challenging to achieve; pain relief, pain freedom at 2 h, sustained pain-freedom, and SPF plus no adverse events (SNAE, the most challenging). QOL questionnaires help assess the burden of migraine and identify optimal treatments. Pain resolution and improved QOL form the basis of the ultimate target-meeting patient expectations, to achieve patient satisfaction. To achieve this, it is crucial to choose appropriate endpoints that reflect realistic treatment goals for individual patients. Moreover, SNAE can help discriminate between triptans, with almotriptan having the highest SNAE score. Kaplan-Meier plots are also relevant when evaluating migraine treatments. The use of symptomatic medication may lead to the paradoxical development of medication-overuse headache. In general practice, patients should use simple tools for pain measurement (e.g. headache diary) and a QOL questionnaire. A composite endpoint of pain resolution and QOL restoration would constitute a step forward in migraine management
    • …
    corecore