69 research outputs found
Angiomyolipoma of the tunica dartos of the scrotum in infancy
AbstractA 12-month-old boy presented with left scrotal swelling. The mass was irregular, soft, fleshy, and nontender. It adhered to the scrotal skin and gradually enlarged. Operative findings revealed a mass fixed to the scrotal fundus and diagnosed as angiomyolipoma. This is apparently the first report of scrotal angiomyolipoma in infancy
Early Spectroscopy of the 2010 Outburst of U Scorpii
We present early spectroscopy of the recurrent nova U~Sco during the outburst
in 2010. We successfully obtained time-series spectra at 0.37--0.44~d, where denotes the time from the discovery of the
present outburst. This is the first time-resolved spectroscopy on the first
night of U Sco outbursts. At ~d the H line consists
of a blue-shifted ( km s) narrow absorption component and a wide
emission component having triple peaks, a blue ( km s), a
central ( km s) and a red ( km s) ones. The
blue and red peaks developed more rapidly than the central one during the first
night. This rapid variation would be caused by the growth of aspherical wind
produced during the earliest stage of the outburst. At ~d the
H line has a nearly flat-topped profile with weak blue and red peaks at
km s. This profile can be attributed to a nearly
spherical shell, while the asphericity growing on the first night still
remains. The wind asphericity is less significant after d.Comment: 5 pages, 3 figures, Accepted for publication of PASJ Letter
Fundamental physics activities with pulsed neutron at J-PARC(BL05)
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for
studies of fundamental physics. The beamline is divided into three branches so
that different experiments can be performed in parallel. These beam branches
are being used to develop a variety of new projects. We are developing an
experimental project to measure the neutron lifetime with total uncertainty of
1 s (0.1%). The neutron lifetime is an important parameter in elementary
particle and astrophysics. Thus far, the neutron lifetime has been measured by
several groups; however, different values are obtained from different
measurement methods. This experiment is using a method with different sources
of systematic uncertainty than measurements conducted to date. We are also
developing a source of pulsed ultra-cold neutrons (UCNs) produced from a
Doppler shifter are available at the unpolarized beam branch. We are developing
a time focusing device for UCNs, a so called "rebuncher", which can increase
UCN density from a pulsed UCN source. At the low divergence beam branch, an
experiment to search an unknown intermediate force with nanometer range is
performed by measuring the angular dependence of neutron scattering by noble
gases. Finally the beamline is also used for the research and development of
optical elements and detectors. For example, a position sensitive neutron
detector that uses emulsion to achieve sub-micrometer resolution is currently
under development. We have succeeded in detecting cold and ultra-cold neutrons
using the emulsion detector.Comment: 9 pages, 5 figures, Proceedings of International Conference on
Neutron Optics (NOP2017
島根県内看護師のキャリア形成に資する継続教育へのニーズ調査 : 看護職代表者への調査
島根県内看護師のキャリア形成支援に関する実態及びニーズ把握を目的に、県内100床以上の病院40施設と訪問看護ステーション50施設の看護職代表者に調査を依頼し、47施設の回答を得た。認定看護師がいる割合は、病院では24施設中11施設(45.8%)、訪問看護ステーションでは23施設中1施設(4.3%)であった。現在の認定看護師数49名に対し、必要数の合計は306名であった。しかし、今後10年以内の育成予定数は58名と、目処は立っていない状況がみられた。必要数の多かった認定看護師分野は「皮膚・排泄ケア」「摂食・嚥下障害看護」「認知症看護」であった。島根県立大学に期待する継続教育支援として、「実習指導者の養成・指導者向けの講座」「認定看護師養成講座」「研究支援」等が高かった
Real-time 3D Photoacoustic Visualization System with a Wide Field of View for Imaging Human Limbs [version 2; referees: 2 approved]
Background: A breast-specific photoacoustic imaging (PAI) system prototype equipped with a hemispherical detector array (HDA) has been reported as a promising system configuration for providing high morphological reproducibility for vascular structures in living bodies. Methods: To image the vasculature of human limbs, a newly designed PAI system prototype (PAI-05) with an HDA with a higher density sensor arrangement was developed. The basic device configuration mimicked that of a previously reported breast-specific PAI system. A new imaging table and a holding tray for imaging a subject's limb were adopted. Results: The device’s performance was verified using a phantom. Contrast of 8.5 was obtained at a depth of 2 cm, and the viewing angle reached up to 70 degrees, showing sufficient performance for limb imaging. An arbitrary wavelength was set, and a reasonable PA signal intensity dependent on the wavelength was obtained. To prove the concept of imaging human limbs, various parts of the subject were scanned. High-quality still images of a living human with a wider size than that previously reported were obtained by scanning within the horizontal plane and averaging the images. The maximum field of view (FOV) was 270 mm × 180 mm. Even in movie mode, one-shot 3D volumetric data were obtained in an FOV range of 20 mm in diameter, which is larger than values in previous reports. By continuously acquiring these images, we were able to produce motion pictures. Conclusion: We developed a PAI prototype system equipped with an HDA suitable for imaging limbs. As a result, the subject could be scanned over a wide range while in a more comfortable position, and high-quality still images and motion pictures could be obtained
保健師基礎教育に関する調査 : 島根県内の行政保健師への調査
今後の保健師基礎教育のあり方を検討するために島根県内の行政保健師を対象に「保健師基礎教育に関する調査」を行い、県保健師63名(91.3%の回答率)、市町村保健師213名(83.5%の回答率)の回答を得た。大学院教育における保健師基礎教育について、県保健師の41.3%、市町村保健師の31.9%が必要性があると回答した。本学に大学院が設置された場合の必要なコースについては、県保健師の68.3%、市町村保健師の49.3%が保健師養成の公衆衛生看護コースと回答していた。本学の大学教育の方向性として、現場の保健師からは、保健師基礎教育の充実を含め、看護職のスキルアップとしての大学院設置が期待されていた
- …