452 research outputs found

    Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.

    Get PDF
    PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA

    Crystal structures of self-assembled nanotubes from flexible macrocycles by weak interactions

    Get PDF
    8 páginas, 7 figuras, 2 tablas, 2 esquemas.Herein we report the crystal structures of tubular self-assemblies of flexible macrooligolides. The assembly is driven by the propensity of the macrocycles to create nearly flat structures displaying a void space within them and the cooperativity of weak directional interactions such as dipole–dipole interactions and CH***Ohydrogen bonds and non-directional interactions such as van der Waals contacts. The significance of the stereochemistry and the size of the cavity in the formation of the nanotubes are also studied.This research was supported by the Spanish MICINN-FEDER (CTQ2008-03334/BQU, CTQ2008-06806-C02-01/BQU and CTQ2008-06754-C04-01/PPQ), the MSC (RTICC RD06/0020/ 1046) and the Canary Islands FUNCIS (PI 01/06).Peer reviewe

    Catheter ablation or medical therapy to delay progression of atrial fibrillation : The randomized controlled atrial fibrillation progression trial (ATTEST)

    Get PDF
    Funding Information: This work was supported by Biosense Webster, Inc. Publisher Copyright: © 2020 The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology.Aims: Delay of progression from paroxysmal to persistent atrial fibrillation (AF) is an important measure of long-term success of AF treatment. However, published data on the impact of catheter ablation on AF progression are limited. This study evaluates whether radiofrequency (RF) catheter ablation delays the progression of AF compared with antiarrhythmic drug (AAD) treatment using current AF management guidelines. Methods: This prospective, randomized, controlled, two-arm, open-label trial was conducted at 29 hospitals and medical centres across 13 countries. Patients were randomized 1: 1 to RF ablation or AAD treatment. The primary endpoint was the rate of persistent AF/atrial tachycardia (AT) at 3 years. Results: After early study termination following slow enrolment, 255 (79%) of the planned 322 patients were enrolled (RF ablation, n = 128, AAD, n = 127); 36% of patients in the RF ablation group and 41% in the AAD group completed 3 years of follow-up. For the primary endpoint, the Kaplan-Meier estimate of the rate of persistent AF/AT at 3 years was significantly lower with RF ablation [2.4% (95% confidence interval (CI), 0.6-9.4%)] than with AAD therapy [17.5% (95% CI, 10.7-27.9%); one-sided P = 0.0009]. Patients ≥65 years were ∼4 times more likely to progress to persistent AF/AT than patients <65 years, suggesting RF ablation can delay disease progression [hazard ratio: 3.87 (95% CI, 0.88-17.00); P = 0.0727]. Primary adverse events were reported for eight patients in the RF ablation group. Conclusions: Radiofrequency ablation is superior to guideline-directed AAD therapy in delaying the progression from paroxysmal to persistent AF.publishersversionPeer reviewe

    Five-year outcome in 18 010 patients from the German Aortic Valve Registry

    Get PDF
    OBJECTIVES: To determine the 5-year outcome in patients treated by isolated transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (sAVR)—a prospective observational cohort study. METHODS: A total of 18 010 patients were included (n = 8942 TAVI and n = 9068 sAVR) in the German Aortic Valve Registry (GARY) who were treated in 2011 and 2012 at 92 sites in central Germany. Eligible patients with TAVI and sAVR were matched using propensity scores in a nearest-neighbour approach. Patients with repeat procedures or unequivocal indication for one treatment option (e.g. frailty) were excluded (n = 4785 for TAVI and n = 2 for sAVR). This led to 13 223 patients (4157 TAVI and 9066 sAVR) as an unmatched subcohort. The main outcome measure was the 5-year all-cause mortality. RESULTS: TAVI patients were significantly older (80.9 ± 6.1 vs 68.5 ± 11.1 years, P < 0.001), had a higher Society of Thoracic Surgeons (STS) score (6.3 ± 4.9 vs 2.6 ± 3.0, P < 0.001) and a higher 5-year all-cause mortality (49.8% vs 16.5%, P < 0.0001). There was no major difference in in-hospital stroke, in-hospital myocardial infarction, or temporary and chronic dialysis. In the propensity score-matched group (n = 3640), there were 763 deaths (41.9%) among 1820 TAVI patients compared with 552 (30.3%) among 1820 treated with sAVR during the 5-year follow-up (hazard ratio 1.51, 95% confidence interval 1.35–1.68; P < 0.0001). New pacemaker implantation was performed in 448 patients (24.6%) after TAVI and in 201 (11.0%) after sAVR (P < 0.0001). CONCLUSIONS: The 5-year follow-up data show that TAVI patients were significantly older and had a higher STS score than sAVR patients. After propensity score matching, TAVI with early-generation prosthesis was associated with significantly higher 5-year all-cause mortality than sAVR

    A Comparative Assessment of Machine-Learning Techniques for Forest Degradation Caused by Selective Logging in an Amazon Region Using Multitemporal X-Band SAR Images.

    Get PDF
    Abstract: The near-real-time detection of selective logging in tropical forests is essential to support actions for reducing CO2 emissions and for monitoring timber extraction from forest concessions in tropical regions. Current operating systems rely on optical data that are constrained by persistent cloud-cover conditions in tropical regions. Synthetic aperture radar data represent an alternative to this technical constraint. This study aimed to evaluate the performance of three machine learning algorithms applied to multitemporal pairs of COSMO-SkyMed images to detect timber exploitation in a forest concession located in the Jamari National Forest, Rondônia State, Brazilian Amazon. The studied algorithms included random forest (RF), AdaBoost (AB), and multilayer perceptron artificial neural network (MLP-ANN). The geographical coordinates (latitude and longitude) of logged trees and the LiDAR point clouds before and after selective logging were used as ground truths. The best results were obtained when the MLP-ANN was applied with 50 neurons in the hidden layer, using the ReLu activation function and SGD weight optimizer, presenting 88% accuracy both for the pair of images used for training (images acquired in June and October) of the network and in the generalization test, applied on a second dataset (images acquired in January and June). This study showed that X-band SAR images processed by applying machine learning techniques can be accurately used for detecting selective logging activities in the Brazilian Amazon

    Sex-specific efficacy and safety of cryoballoon versus radiofrequency ablation for atrial fibrillation: An individual patient data meta-analysis

    Get PDF
    BACKGROUND: Atrial fibrillation (AF) is a growing health burden, and pulmonary vein isolation (PVI) using cryoballoon (CB) or radiofrequency (RF) represents an attractive therapeutic option. Sex-specific differences in the epidemiology, pathophysiology, and clinical presentation of AF and PVI are recognized. OBJECTIVE: We aimed at comparing the efficacy, safety, and procedural characteristics of CB and RF in women and men undergoing a first PVI procedure. METHODS: We searched for randomized controlled trials and prospective observational studies comparing CB and RF ablation with at least 1 year of follow-up. After merging individual patient data from 18 data sets, we investigated the sex-specific (procedure failure defined as recurrence of atrial arrhythmia, reablation, and reinitiation of antiarrhythmic medication), safety (periprocedural complications), and procedural characteristics of CB vs RF using Kaplan-Meier and multilevel models. RESULTS: From the 18 studies, 4840 men and 1979 women were analyzed. An analysis stratified by sex correcting for several covariates showed a better efficacy of CB in men (hazard ratio for recurrence 0.88; 95% confidence interval 0.78-0.98, P = .02) but not in women (hazard ratio 0.98; 95% confidence interval 0.83-1.16; P = .82). For women and men, the energy source had no influence on the occurrence of at least 1 complication. For both sexes, the procedure time was significantly shorter with CB (-22.5 minutes for women and -27.1 minutes for men). CONCLUSION: CB is associated with less long-term failures in men. A better understanding of AF-causal sex-specific mechanisms and refinements in CB technologies could lead to higher success rates in women
    corecore