4 research outputs found

    Inter-observer variation of hippocampus delineation in hippocampal avoidance prophylactic cranial irradiation

    Get PDF
    Background: Hippocampal avoidance prophylactic cranial irradiation (HA-PCI) techniques have been developed to reduce radiation damage to the hippocampus. An inter-observer hippocampus delineation analysis was performed and the influence of the delineation variability on dose to the hippocampus was studied. Materials and methods: For five patients, seven observers delineated both hippocampi on brain MRI. The intra-class correlation (ICC) with absolute agreement and the generalized conformity index (CIgen) were computed. Median surfaces over all observers’ delineations were created for each patient and regional outlining differences were analysed. HA-PCI dose plans were made from the median surfaces and we investigated whether dose constraints in the hippocampus could be met for all delineations. Results: The ICC for the left and right hippocampus was 0.56 and 0.69, respectively, while the CIgen ranged from 0.55 to 0.70. The posterior and anterior-medial hippocampal regions had most variation with SDs ranging from approximately 1 to 2.5 mm. The mean dose (Dmean) constraint was met for all delineations, but for the dose received by 1% of the hippocampal volume (D1%) violations were observed. Conclusion: The relatively low ICC and CIgen indicate that delineation variability among observers for both left and right hippocampus was large. The posterior and anterior-medial border have the largest delineation inaccuracy. The hippocampus Dmean constraint was not violated

    An instrument dedicated for modelling of pulmonary radiotherapy

    No full text
    Background and purpose: Radiotherapy plays a pivotal role in lung cancer treatment. Selection of patients for new (radio)therapeutic options aiming at improving outcomes requires reliable and validated prediction models. We present the implementation of a prospective platform for evaluation and development of lung radiotherapy (proPED-LUNG) as an instrument enabling multidimensional predictive modelling. Materials and methods: ProPED-LUNG was designed to comprise relevant baseline and follow up data of patients receiving pulmonary radiotherapy with curative intent. Patient characteristics, diagnostic and staging information, treatment parameters including full dose-volume-histograms, tumour control, survival, and toxicity are scored. Besides physician-rated data, a range of patient-rated data regarding symptoms and health-related quality-of-life are collected. Results: After 18 months of accrual, 315 patients have been included (accrual rate, 18 per month). Of the first hundred patients included, 70 received conformal (chemo)radiotherapy and 30 underwent stereotactic radiotherapy. Compliance at 3 and 6 months follow-up was 96-100% for patient-rated, and 8194% for physician-rated assessments. For data collection, 0.4 FTE were allocated in a 183 FTE department (0.2%). Conclusions: ProPED-LUNG is feasible with high compliance rates and yields a large amount of high quality prospective disease-related, treatment-related, patient- and physician-rated data which can be used to evaluate new developments in pulmonary radiotherapy. (C) 2015 Elsevier Ireland Ltd. All rights reserved
    corecore