Electrochemical and mechanical behavior of laser processed Tiā6Alā4V surface in Ringerās physiological solution
Laser surface modiļ¬cation of Tiā6Alā4V with
an existing calcium phosphate coating has been conducted
to enhance the surface properties. The electrochemical and
mechanical behaviors of calcium phosphate deposited on a
Tiā6Alā4V surface and remelted using a Nd:YAG laser at
varying laser power densities (25ā50 W/mm
2
) have been
studied and the results are presented. The electrochemical
properties of the modiļ¬ed surfaces in Ringerās physiolog-
ical solution were evaluated by employing both potentio-
dynamic polarization and electrochemical impedance
spectroscopy (EIS) methods. The potentiodynamic polar-
izations showed an increase in the passive current density
of Tiā6Alā4V after laser modiļ¬cation at power densities
up to 35 W/mm
2
, after which it exhibited a decrease.
A reduction in the passive current density (by more than an
order) was observed with an increase in the laser power
density from 25 to 50 W/mm
2
. EIS studies at the open
circuit potential (OCP) and in the passive region at 1.19 V
showed that the polarization resistance increased from
8.274 9 10
3
to 4.38 9 10
5
X cm
2
with increasing laser
power densities. However, the magnitudes remain lower
than that of the untreated Tiā6Alā4V at OCP. The average
hardness and modulus of the laser treated Tiā6Alā4V,
evaluated by the nanoindentation method, were deter-
mined to be 5.4ā6.5 GPa (with scatter \Ā±0.976 GPa)
and 124ā155 GPa (with scatter \Ā±13 GPa) respectively.
The corresponding hardness and modulus of untreated
Tiā6Alā4V were *4.1 (Ā±0.62) and *148 (Ā±7) GPa respec-
tively. Laser processing at power densities [35 W/mm
2 enhanced the surface properties (as passive current density is reduced) so that the materials may be suitable for the bio-medical applications
Sliding Wear Behavior of Al2O3-TiO2 Coatings Fabricated by the Suspension Plasma Spraying Technique
[EN] The friction and dry sliding wear behavior of alumina and alumina-titania near-nanometric coatings were examined. Coatings were obtained by the suspension plasma spraying technique. Dry sliding wear tests were performed on a ball-on-disk tribometer, with an Al2O3 ball as counterpart material, a normal load of 2 N, a sliding distance of 1200 m and a sliding speed of 0.1 m/s. The effect of including TiO2 in the fabricated coatings on friction coefficient behavior, wear rates and wear damage patterns was determined. The addition of TiO2 to the coatings was found to greatly increase wear resistance by, for example, 2.6-fold for 40 wt% of TiO2. The analysis of the wear surface was correlated with microstructural parameters, mechanical properties and wear rates.The authors wish to thank for the Spanish Ministry of Economy and Competitiveness (MAT2012-38364-C03) and the Autonomous Government of Valencia for funding for the stay in SPCTS-UMR CNRS (France), and the French FCENANOSURF consortium funded by the French Ministry and Industry and local governments of Region Centre and Region Limousin.Klyatskina, E.; Espinosa FernĆ”ndez, L.; Darut, G.; Segovia LĆ³pez, EF.; Salvador Moya, MD.; Montavon, G.; Agorges, H. (2015). Sliding Wear Behavior of Al2O3-TiO2 Coatings Fabricated by the Suspension Plasma Spraying Technique. Tribology Letters. 59(1):1-9. https://doi.org/10.1007/s11249-015-0530-5S19591Pawlowski, L.: The Science and Engineering of Thermal Spray Coatings. Wiley: Hoboken (2008)Lampe, Th, Eisenberg, S., Cabeo, E.R.: Plasma surface engineering in the automotive industryātrends and future prospective. Surf. Coat. Technol. 174ā175, 1ā7 (2003)Wang, Y., Jiang, S., Wang, M., Wang, S., Xiao, T.D., Strutt, P.R.: Abrasive wear characteristics of plasma sprayed nanostructured alumina/titania coatings. Wear 237, 176ā185 (2000)Kabacoff, L.T.: Nanoceramic coatings exhibit much higher toughness and wear resistance than conventional coatings. AMPITAC Newslett. 6(1), 37ā42 (2002)Wang, M., Shaw, L.L.: Effects of the powder manufacturing method on microstructure and wear performance of plasma sprayed aluminaātitania coatings. Surf. Coat. Technol. 202, 34ā44 (2007)Shaw, L.L., Goberman, D., Ren, R., Gell, M., Jing, S., Wang, Y., Xiao, T.D., Strutt, P.R.: The dependency of microstructure and properties of nanostructured coatings on plasma spray conditions. Surf. Coat. Technol. 130, 1ā8 (2000)Dahotre, N.B., Nayak, S.: Nanocoatings for engine application. Surf. Coat. Technol. 194(1), 58ā67 (2005)Sathish, S., Geetha, M., Aruna, S.T., Balaji, N., Rajam, K.S., Asokamani, R.: Sliding wear behavior of plasma sprayed nanoceramic coatings for biomedical applications. Wear 271, 934ā941 (2011)Pawlowski, L.: Finely grained nanometric and submicrometric coatings by thermal sparing: a review. Surf. Coat. Technol. 202, 4318ā4328 (2008)Xiao, D., Wang, Y., Strutt, P.: Fabrication and evaluation of plasma sprayed nanostructured aluminaātitania coatings with superior properties. Mater. Sci. Eng. 301, 80ā89 (2001)Tjong, S.C., Chen, H.: Nanocrystalline materials and coatings. Mater. Sci. Eng. 45, 1ā88 (2004)Fauchais, P., Montavon, G., Bertrand, G.: From powders to thermally sprayed coatings. J. Therm. Spray Technol. 19, 56ā80 (2010)Lima, R.S., Marple, B.R.: Thermal spray coatings engineered from nanostructured ceramic agglomerated powders for structural, thermal barrier and biomedical applications: a review. J. Therm. Spray Technol. 16, 40ā63 (2007)Fauchais, P., Etchart-Salas, R., Delbos, C., Tognonvi, M., Rat, V., Coudert, J.F., Chartier, T.: Suspension and solution plasma spraying of finely structured layers: potential application to SOFCs. J. Phys. D Appl. Phys. 40, 2394ā2406 (2007)Ramachandran, K., Selvajaran, V., Ananthapadmanabhan, P.V., Sreekumar, K.P.: Microstructure, adhesion, micro hardness, abrasive wear resistance and electrical resistivity of the plasma sprayed alumina and aluminaātitania coatings. Thin Solid Films 315, 144ā152 (1998)Lee, S.W., Morillo, C., Lira-Olivares, J., Kim, S.H., Sekino, T., Niihara, K., Hockey, B.J.: Tribological and microstructural analysis of Al2O3/13TiO2 nanocomposites to use in femoral head of hip replacement. Wear 225, 1040ā1044 (2003)Dejang, N., Watcharapasorn, A., Wirojupatump, S., Niranatlumpong, P., Jiansirisomboon, S.: Fabrication and properties of plasma-sprayed Al2O3/TiO2 composite coatings: a role of nano-sized TiO2 addition. Surf. Coat. Technol. 204, 1651ā1657 (2010)Yimaz, S.: An evaluation of plasma sprayed coatings based on Al2O3 and Al2O3ā13wt% TiO2 with bond coat on pure titanium substrate. Ceram. Int. 35, 2017ā2022 (2009)Fervel, V., Normand, B., Coddet, C.: Tribological behavior of plasma sprayed Al2O3-based cermet coatings. Wear 230(1), 70ā77 (1999)Vargas, F., Ageorges, H., Fauchais, P., LĆ³pez, M.E.: Mechanical and a tribological performance of Al2O3 coatings elaborated by flame and plasma spraying. Surf. Coat. Technol. 205, 1132ā1136 (2010)Bacciochini, A., Ilavsky, J., Montavon, G., Denoirjean, A., Ben-ettouil, F., Valette, S., Fauchais, P., Wittmann-teneze, K.: Quantification of void network architectures of suspension plasma-sprayed (SPS) yttria-stabilized zirconia (YSZ) coatings using ultra-small-angle X-ray scattering (USAXS). Mater. Sci. Eng. 528, 91ā102 (2010)ASTM International: ASTM G99-03: Standard test method for wear testing with a pin-on-disc apparatus. ASTM annual book of standards. ASTM International: West Conshohocken (2003)Lancaster, K.: The influence of substrate hardness on the formation and endurance of molybdenum disulphide films. Wear 10, 103ā107 (1967)Fauchais, P., Rat, V., Delbos, C., Fazilleau, J., Coudert, J.F., Chartier, T., Bianchi, L.: Understanding of suspension plasma spraying of finely structured coatings for SOFC. IEEE Plasma Sci. 33(2), 920ā930 (2005)Bannier, E., Vicent, M., RayĆ³n, E., Benavente, R., Salvador, M.D., SĆ”nchez, E.: Effect of TiO2 addition on the microstructure and nanomechanical properties of Al2O3 suspension plasma sprayed coatings. Appl. Surf. Sci. 316, 141ā146 (2014)Darut, G., Klyatskina, E., Valette, S., Carles, P., Denoirjean, A., Montavon, G., Ageorges, H., Segovia, F., Salvador, M.D.: Architecture and phases composition of suspension plasma sprayed aluminaātitania sub-micrometer-sized coatings. Mater. Lett. 67, 241ā244 (2012)Fauchais, P., Montavon, G.: Latest developments in suspension and liquid precursor thermal spraying. J. Therm. Spray Technol. 19(1ā2), 226ā239 (2010)Darut, G., Ben-Ettouli, F., Denoirjean, A., Montavon, G., Ageourges, H., Fauchais, P.: Dry sliding behavior of sub-micrometer-sized suspension plasma sprayed ceramic oxide coatings. J. Therm. Spray Technol. 19, 275ā285 (2010)Tingaud, O., Bacciochini, A., Montavon, G., Denoirjean, A., Fauchais, P.: Suspension DC plasma spraying of thick finely-structured ceramic coatings: process manufacturing mechanisms. Surf. Coat. Technol. 203, 2157ā2161 (2009)Guesama, S., Bounazef, M., Nardin, P., Sahraoui, T.: Wear behavior of aluminaātitania coatings: analysis of process and parameters. Ceram. Int. 32, 13ā19 (2006)Espinosa-FernĆ”ndez, L., Borrell, A., Salvador, M.D., Gutierrez-Gonzalez, C.F.: Sliding wear behavior of WCāCoāCr3C2āVC composites fabricated by conventional and non-conventional techniques. Wear 307, 60ā67 (2013)Zhang, J., Moslehy, F.A., Rice, S.L.: A model for friction in quasi-steady-state. Part I. Derivation. Wear 149, 1ā12 (1991)Zhang, J., Moslehy, F.A., Rice, S.L.: A model for friction in quasi-steady-state sliding Part II. Numerical results and discussion. Wear 149, 13ā25 (1991)Bolelli, G., Cannilo, V., Lusvarghi, L., Manfredini, T.: Wear behaviour of thermally sprayed ceramic oxide coatings. Wear 261, 1298ā1315 (2006)Normand, B., Fervel, V., Coddet, C., Nikitine, V.: Tribological properties of plasma sprayed aluminaātitania coatings: next term role and control of the microstructure. Surf. Coat. Technol. 123, 278ā287 (2000)Hutchings, I.: Tribology: friction and wear of engineering materials. Mater. Des. 13, 187 (1992)Ahn, J., Hwang, B., Song, E.P., Lee, S., Kim, N.J.: Correlation of microstructure and wear resistance of Al2O3āTiO2 coatings plasma sprayed with nanopowders. Metall. Mater. Trans. A 37, 1851ā1860 (2006)Erickson, L.C., Hawthorne, H.M., Troczynski, T.: Correlations between microstructural parameters, micromechanical properties and wear resistance of plasma sprayed ceramic coatings. Wear 250, 569ā575 (2001)Song, E.P., Ahn, J., Lee, S., Kim, N.J.: Microstructure and wear resistance of nanostructured Al2O3ā8Ā wt%TiO2 coatings plasma-sprayed with nanopowders. Surf. Coat. Technol. 201, 1309ā1315 (2006)Tucker Jr., R.C.: ASM Handbook Volume 5A: Thermal Spray Technology. ASM International, Materials Park (2013)Stachowiack, G.W., Batchelor, A.: Engineering Tribology Handbook. Elsevier-Butterworth-Heineman: Oxford (2005)Fischer, T.E., Zhu, Z., Kim, H., Shin, D.S.: Genesis and role of wear debris in sliding wear of ceramics. Wear 245, 53ā60 (2000)Lima, R.S., Moureau, C., Marple, B.R.: HVOF-sprayed coatings engineered from mixtures of nanostructured and submicron Al2O3āTiO2 powders: an enhanced wear performance. J. Therm. Spray Technol. 16, 866 (2007
Tribology of laser modiļ¬ed surface of stainless steel in physiological solution
The laser surface treatment of stainless steel (SS) 316L, an important alloy for biomedical applications, was used to improve its corrosion and wear-corrosion resistance in
bio-environment. Microstructural and X-ray diffraction (XRD) pattern analysis showed presence of an austenitic phase in both untreated and laser-treated SS316L. Laser melting
produced homogenized and reļ¬ned microstructure on the surface with higher hardness (143ā171 HV) compared to untreated SS316L (131 HV). Increase in intensity of Ī³ (200) peaks in XRD pattern for laser-treated ( > 800 W) SS316L indicated possible crystallographic orientation along Ī³ (200) plane. Passive currents were reduced to + 344 mV for samples laser surface treated at greater than 1200 W. The volume-loss and wear-rate of laser-treated SS316L were signiļ¬cantly reduced compared to untreated sample. Abrasive wear was the main wear mechanism for both untreated and laser surface treated SS316L. Wear particles/debris were found to be cold welded on the surface of SS316L and showed brittle cracking with further wear-straining
Corrosion degradation and prevention by surface modification of biometallic materials
Metals, in addition to ceramics and polymers, are important class of materials considered for replacement of non-functional parts in the body. Stainless steel 316, titanium and titanium alloys, Co-Cr, and nitinol shape memory alloys are the most frequently used metallic materials. These alloys are prone to corrosion in various extents. This review briefly discusses the important biomaterials, their properties, and the physiological environment to which these materials are exposed. Corrosion performance of currently used metallic materials has been assessed and threat to the biocompatibility from corrosion products/metal ions is discussed. The possible preventive measures to improve corrosion resistance by surface modification and to increase the bioactivity of the metallic surfaces have also been discussed. Importance of the formation of oxide layers on the metal surface, another aspect of corrosion process, has been correlated with the host response. The gap areas and future direction of research are also outlined in the paper
Laser Surface Modification of Tiā6Alā4V: Wear and Corrosion Characterization in Simulated Biofluid
Laser surface melting (LSM) of Tiā6Alā4V is performed in argon to improve its properties, such as microstructure, corrosion, and wear for biomedical applications. Corrosion behavior is investigated by conducting electrochemical polarization experiments in simulated body fluid (Ringerās solution) at 37 C. Wear properties are evaluated in Ringerās solution using pin-on-disc apparatus at a slow speed. Untreated Tiā6Alā4V contains Ć¾ phase. After laser surface melting, it transforms to acicular embedded in the prior matrix. Grain growth in
the range of 65ā89 mm with increase in laser power from 800 to 1500 W due to increase in associated temperature is observed. The hardness of as-laser-
processed Tiā6Alā4V alloy is more (275ā297 HV) than that of the untreated alloy
(254 HV). Passivation currents are significantly reduced to <4.3 mA/cm2 after laser treatment compared to untreated Tiā6Alā4V (12 mA/cm2). The wear resistance of laser-treated Tiā6Alā4V in simulated body fluid is enhanced
compared to that of the untreated one. It is the highest for the one that is processed at a laser power of 800 W. Typical micro-cutting features of abrasive wear is the prominent mechanism of wear in both untreated and as-laser-treated Tiā6Alā4V. Fragmentation of wear debris assisted by microcracking was responsible for mass loss during the wear of untreated Tiā6Alā4V in Ringerās solution
Influence of laser surface modification on corrosion behavior of stainless steel 316L and Ti-6Al-4V in simulated biofluid
Laser surface engineering has been explored as a possible method for improving the functional surface properties of biomedical materials such as stainless steels and titanium alloys. This study emphasises the influence of laser surface processing, carried out at a range of laser powers from 500 to 1500 W in ambient atmosphere, on the surface microstructure and corrosion behaviour of stainless steel 316L (SS316L) and Ti-6Al-4V, and metal ions released during the corrosion process. A homogeneous surface microstructure includes columnar dendrites and fine grains in the resolidified region of SS316L. A gradual increase in grain size from the processed surface towards the substrate was revealed, The laser processing of Ti-6Al-4V produced a surface full of dendrites followed by acicular martensite in the interface region. The corrosion studies in Ringer's physiological solution showed an increase in the open circuit potential (OCP) as a result of laser surface treatment of both SS316L and Ti-6Al-4V (more noble than untreated). After laser processing, the corrosion properties of SS316L were seen to deteriorate, and those of Ti-6Al-4V to improve, as compared to their respective untreated counterparts. The variation of laser power influenced the corrosion resistance of SS316L, while that of Ti-6Al-4V did not vary significantly. Laser surface treatments at higher powers (> 1000 W) reduced the leaching of specific metallic ions from SS316L and Ti-6Al-4V during corrosion in Ringer's physiological solutio
- ā¦