9 research outputs found

    “A New Era in Advanced Heart Failure Therapy” : Left ventricular assist devices

    Get PDF
    This thesis aims to assess the current body of evidence and experiences with continuous flow-LVADs in the new era of advanced heart failure therapy. Furthermore, we investigate clinical outcomes, complications, and the impact of LVAD on end-organ function. In addition, an effort was made to predict these end-points in order to improve the selection criteria for LVAD therapy and current clinical practice

    Modification of a Ventricular Assistance Device for a Hemiplegic Left Ventricular Assist Device Patient

    Get PDF
    Neurologic events occur in up to 18% of patients with continuous-flow left ventricular assist devices (LVAD) and is associated with significant morbidity and mortality. The current form of the LVAD equipment is not suited to serve patients who are impaired by a stroke. By creating an assistance device for the LVAD equipment, we have been able to greatly improve the quality of life and self-dependence of a hemiplegic LVAD patient

    Causes and predictors of early mortality in patients treated with left ventricular assist device implantation in the European Registry of Mechanical Circulatory Support (EUROMACS)

    Get PDF
    Purpose: The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. Methods: We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. Results: Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. Conclusions: In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation

    Outcomes of patients after successful left ventricular assist device explantation: a EUROMACS study

    Get PDF
    Aims: Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1–2% of the cases. However, follow-up data about this condition are scarcely available in the literature. This study aimed to report the long-term outcomes and clinical management following LVAD explantation. Methods and results: An analysis of the European Registry for Patients with Mechanical Circulatory Support was performed to identify all adult patients with myocardial recovery and successful explantation. Pre-implant characteristics were retrieved and compared with the non-recovery patients. The follow-up data after explantation were collected via a questionnaire. A Kaplan–Meier analysis for freedom of the composite endpoint of death, heart transplantation, LVAD reimplantion, or heart failure (HF) relapse was conducted. A total of 45 (1.4%) cases with myocardial recovery resulting in successful LVAD explantation were identified. Compared with those who did not experience myocardial recovery, the explanted patients were younger (44 vs. 56 years, P < 0.001), had a shorter duration of cardiac disease (P < 0.001), and were less likely to have ischaemic cardiomyopathy (9% vs. 41.8%, P < 0.001). Follow-up after explantation could be acquired in 28 (62%) cases. The median age at LVAD implantation was 43 years (inter-quartile range: 29–52),

    Evaluation of patients with a HeartMate 3 left ventricular assist device using echocardiographic particle image velocimetry

    Get PDF
    Purpose: Poor left ventricular (LV) function may affect the physiological intraventricular blood flow and physiological vortex formation. The aim of this study was to investigate the pattern of intraventricular blood flow dynamics in patients with LV assist devices (LVADs) using echocardiographic particle image velocimetry. Materials and methods: This prospective study included 17 patients (mean age 57 ± 11 years, 82% male) who had received an LVAD (HeartMate 3, Abbott Laboratories, Chicago, Illinois, USA) because of end-stage heart failure and poor LV function. Eleven (64%) patients had ischemic cardiomyopathy, and six patients (36%) had nonischemic cardiomyopathy. All patients underwent echocardiography, including intravenous administration of an ultrasound-enhancing agent (SonoVue, Bracco, Milan, Italy). Echocardiographic particle image velocimetry was used to quantify LV blood flow dynamics, including vortex formation (Hyperflow software, Tomtec imaging systems Gmbh, Unterschleissheim, Germany). Results: Contrast-enhanced ultrasound was well tolerated in all patients and was performed without adverse reactions or side effects. The LVAD function parameters did not change during or after the ultrasound examination. The LVAD flow was on average 4.3 ± 0.3 L/min, and the speed was 5247 ± 109 rotations/min. The quantification of LV intraventricular flow demonstrated substantial impairment of vortex parameters. The energy dissipation, vorticity, and kinetic energy fluctuation indices were severely impaired. Conclusions: Echo particle velocimetry is safe and feasible for the quantitative assessment of intraventricular flow in patients with an LVAD. The intraventricular LV flow and vortex parameters are severely impaired in these patients

    Impact of Continuous Flow Left Ventricular Assist Device Therapy on Chronic Kidney Disease: A Longitudinal Multicenter Study

    Get PDF
    Background: Many patients undergoing durable left ventricular assist device (LVAD) implantation suffer from chronic kidney disease (CKD). Therefore, we investigated the effect of LVAD support on CKD. Methods: A retrospective multicenter cohort study, including all patients undergoing LVAD (HeartMate II (n = 330), HeartMate 3 (n = 22) and HeartWare (n = 48) implantation. In total, 227 (56.8%) patients were implanted as bridge-to-transplantation; 154 (38.5%) as destination therapy; and 19 (4.7%) as bridge-to-decision. Serum creatinine measurements were collected over a 2-year follow-up period. Patients were stratified based on CKD stage. Results: Overall, 400 patients (mean age 53 ± 14 years, 75% male) were included: 186 (46.5%) patients had CKD stage 1 or 2; 93 (23.3%) had CKD stage 3a; 82 (20.5%) had CKD stage 3b; and 39 (9.8%) had CKD stage 4 or 5 prior to LVAD implantation. During a median follow-up of 179 days (IQR 28–627), 32,629 creatinine measurements were available. Improvement of kidney function was noticed in every preoperative CKD-stage group. Following this improvement, estimated glomerular filtration rates regressed to baseline values for all CKD stages. Patients showing early renal function improvement were younger and in worse preoperative condition. Moreover, survival rates were higher in patients showing early improvement (69% vs 56%, log-rank P = 0.013). Conclusions: Renal function following LVAD implantation is characterized by improvement, steady state and subsequent deterioration. Patients who showed early renal function improvement were in worse preoperative condition, however, and had higher survival rates at 2 years of follow-up

    Pediatric Ventricular Assist Device Support in the Netherlands

    Get PDF
    Background: This study aimed to evaluate the changes in heart transplantation (HTx) waiting list mortality following the introduction of the Berlin Heart EXCOR (BH EXCOR) in the Netherlands, as well as the occurrence of adverse events in these children. Methods: A retrospective, single-center study was conducted including all pediatric patients (18 years) awaiting HTx. Patients were grouped in two eras based on availability of the BH EXCOR in our center, era I (1998-2006; not available) and era II (2007 to July 31, 2018; available). Results: In tot
    corecore