54 research outputs found

    Biophysical and electrochemical studies of protein-nucleic acid interactions

    Get PDF
    This review is devoted to biophysical and electrochemical methods used for studying protein-nucleic acid (NA) interactions. The importance of NA structure and protein-NA recognition for essential cellular processes, such as replication or transcription, is discussed to provide background for description of a range of biophysical chemistry methods that are applied to study a wide scope of protein-DNA and protein-RNA complexes. These techniques employ different detection principles with specific advantages and limitations and are often combined as mutually complementary approaches to provide a complete description of the interactions. Electrochemical methods have proven to be of great utility in such studies because they provide sensitive measurements and can be combined with other approaches that facilitate the protein-NA interactions. Recent applications of electrochemical methods in studies of protein-NA interactions are discussed in detail

    Tangential beam IMRT versus tangential beam 3D-CRT of the chest wall in postmastectomy breast cancer patients: A dosimetric comparison

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study evaluates the dose distribution of reversed planned tangential beam intensity modulated radiotherapy (IMRT) compared to standard wedged tangential beam three-dimensionally planned conformal radiotherapy (3D-CRT) of the chest wall in unselected postmastectomy breast cancer patients</p> <p>Methods</p> <p>For 20 unselected subsequent postmastectomy breast cancer patients tangential beam IMRT and tangential beam 3D-CRT plans were generated for the radiotherapy of the chest wall. The prescribed dose was 50 Gy in 25 fractions. Dose-volume histograms were evaluated for the PTV and organs at risk. Parameters of the dose distribution were compared using the Wilcoxon matched pairs test.</p> <p>Results</p> <p>Tangential beam IMRT statistically significantly reduced the ipsilateral mean lung dose by an average of 21% (1129 cGy versus 1437 cGy). In all patients treated on the left side, the heart volume encompassed by the 70% isodose line (V70%; 35 Gy) was reduced by an average of 43% (5.7% versus 10.6%), and the mean heart dose by an average of 20% (704 cGy versus 877 cGy). The PTV showed a significantly better conformity index with IMRT; the homogeneity index was not significantly different.</p> <p>Conclusions</p> <p>Tangential beam IMRT significantly reduced the dose-volume of the ipsilateral lung and heart in unselected postmastectomy breast cancer patients.</p

    Dictator Games: A Meta Study

    Full text link

    Total marrow and total lymphoid irradiation in bone marrow transplantation for acute leukaemia

    No full text
    The use of total body irradiation as part of conditioning regimens for acute leukaemia is progressively declining because of concerns of late toxic effects and the introduction of radiation-free regimens. Total marrow irradiation and total marrow and lymphoid irradiation represent more targeted forms of radiotherapy compared with total body irradiation that have the potential to decrease toxicity and escalate the dose to the bone marrow for high-risk patients. We review the technological basis and the clinical development of total marrow irradiation and total marrow and lymphoid irradiation, highlighting both the possible advantages as well as the current roadblocks for widespread implementation among transplantation units. The exact role of total marrow irradiation or total marrow and lymphoid irradiation in new conditioning regimens seems dependent on its technological implementation, aiming to make the whole procedure less time consuming, more streamlined, and easier to integrate into the clinical workflow. We also foresee a role for computer-assisted planning, as a way to improve planning and delivery and to incorporate total marrow irradiation and total marrow and lymphoid irradiation in multi-centric phase 2–3 trials

    Feasibility study using MRI and two optical CT scanners for readout of polymer gel and Presage (TM)

    No full text
    The aim of this study was to compare the conventional combination of three-dimensional dosimeter (nPAG gel) and readout method (MRI) with other combinations of three-dimensional dosimeters (nPAG gel/Presage (TM)) and readout methods (optical CT scanners). In the first experiment, the dose readout of a gel irradiated with a four field-box technique was performed with both an Octopus IQ scanner and MRI. It was seen that the MRI readout agreed slightly better to the TPS. In another experiment, a gel and a Presage (TM) sample were irradiated with a VMAT field and read out using MRI and a fast laser scanner, respectively. A comparison between the TPS and the volumes revealed that the MRI/gel readout had closer resemblance to the TPS than the optical CT/Presage (TM) readout. There are clearly potential in the evaluated optical CT scanners, but more time has to be invested in the particular scanning scenario than was possible in this study
    corecore