31 research outputs found

    Infliximab biosimilar-to-biosimilar switching in patients with inflammatory rheumatic disease:clinical outcomes in real-world patients from the DANBIO registry

    Get PDF
    OBJECTIVE: Successful uptake of biosimilars in rheumatology is limited by lack of real-world evidence regarding effectiveness of biosimilar-to-biosimilar switching. We investigated infliximab biosimilars CT-P13-to-GP1111 switching among patients with rheumatoid arthritis (RA), psoriatic arthritis (PsA) and axial spondyloarthritis (AxSpA). METHODS: Observational cohort study from the DANBIO registry. Patients were classified as originator-naïve or originator-experienced. Retention rates of 1-year GP1111 treatment were explored (Kaplan-Meier). We identified baseline factors (at the time of switch) associated with withdrawal of GP1111 (multivariable Cox-regression analyses with HRs including originator treatment history). Changes in subjective and objective measures of disease activity 4 months before and after the switch were assessed in individual patients. RESULTS: Of 1605 patients (685 RA, 314 PsA and 606 AxSpA, median disease duration was 9 years, 37% in Clinical Disease Activity Index/Ankylosing Spondylitis Disease Activity Score remission), 1171 were originator-naïve. Retention rates at 1-year were 83% (95% CI: 81% to 85%) and 92% (95% CI: 90% to 95%) for the originator-naïve and originator-experienced, respectively. GP1111 retention rates were higher in originator-experienced compared to originator-naïve with RA (HR=0.4 (95% CI: 0.2 to 0.7)) and PsA (HR=0.2 (95% CI: 0.1 to 0.8)), but not significantly for AxSpA: HR=0.6 (95% CI: 0.3 to 1.2). Lower disease activity was associated with higher retention. Changes in disease activity preswitch and postswitch were close to zero. CONCLUSION: This real-world observational study of more than 1600 patients with inflammatory arthritis showed high 1-year retention following a nationwide infliximab biosimilar-to-biosimilar switch. Retention was higher in originator-experienced and in patients with low disease activity, suggesting outcomes to be affected by patient-related rather than drug-related factors

    Using Polarized Spectroscopy to Investigate Order in Thin-Films of Ionic Self-Assembled Materials Based on Azo-Dyes

    Get PDF
    Three series of ionic self-assembled materials based on anionic azo-dyes and cationic benzalkonium surfactants were synthesized and thin films were prepared by spin-casting. These thin films appear isotropic when investigated with polarized optical microscopy, although they are highly anisotropic. Here, three series of homologous materials were studied to rationalize this observation. Investigating thin films of ordered molecular materials relies to a large extent on advanced experimental methods and large research infrastructure. A statement that in particular is true for thin films with nanoscopic order, where X-ray reflectometry, X-ray and neutron scattering, electron microscopy and atom force microscopy (AFM) has to be used to elucidate film morphology and the underlying molecular structure. Here, the thin films were investigated using AFM, optical microscopy and polarized absorption spectroscopy. It was shown that by using numerical method for treating the polarized absorption spectroscopy data, the molecular structure can be elucidated. Further, it was shown that polarized optical spectroscopy is a general tool that allows determination of the molecular order in thin films. Finally, it was found that full control of thermal history and rigorous control of the ionic self-assembly conditions are required to reproducibly make these materials of high nanoscopic order. Similarly, the conditions for spin-casting are shown to be determining for the overall thin film morphology, while molecular order is maintained

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Bleeding patients on extracorporeal membrane oxygenation have reduced platelet aggregation and plasma fibrinogen: a longitudinal observational study

    No full text
    Abstract This study investigated changes in coagulation and associations with occurrence of bleeding and thrombosis during extracorporeal membrane oxygenation (ECMO) therapy. The study included 100 adult ECMO-patients. Standard coagulation parameters, platelet aggregation and thromboelastometry (ROTEM®) were compared with healthy controls. Data on bleeding and thrombosis were collected until recovery or death. Mortality data were collected 30 days after weaning from ECMO. During ECMO therapy, 53 patients experienced at least one moderate or major bleed. Among these, 42 (79%) patients experienced the first bleeding on day 1 or 2. Platelet aggregation and ROTEM® revealed a hypocoagulable state in ECMO patients when compared with healthy controls. Patients bleeding on day 1 or 2, had lower platelet count (p = 0.04), poorer platelet aggregation and lower levels of fibrinogen (p < 0.01) than patients not bleeding on day 1 or 2. Further, ROTEM® clot propagation was reduced in bleeding patients (p < 0.001). Mortality was higher among bleeding patients than patients not bleeding on day 1 or 2 (67% versus 34%, p < 0.01). Congruity existed between ROTEM® measurements and standard coagulation assays, but plasma fibrinogen had a stronger association with bleeding than ROTEM® measurements. The present study does not support ROTEM® analysis as a routine part of coagulation monitoring during ECMO therapy

    Using thoracic ultrasound to detect interstitial lung disease in patients with rheumatoid arthritis: a protocol for the diagnostic test accuracy AURORA study

    No full text
    Introduction Pulmonary diseases are significant contributors to morbidity and mortality in patients with rheumatoid arthritis (RA). RA-associated interstitial lung disease (RA-ILD) may be prevalent in up to 30% and clinically evident in 10% of patients with RA. Feasible methods to detect concomitant ILD in RA are warranted. Our objective is to determine the diagnostic accuracy of thoracic ultrasound (TUS) for ILD in patients with RA with respiratory symptoms, by using chest high-resolution CT (HRCT) as the reference standard. Further, we aim to evaluate the diagnostic accuracy for the promising blood biomarkers surfactant protein-D and microfibrillar-associated protein 4 in the detection of ILD in this group of patients.Methods and analysis By use of a standardised 14 zone protocol patients suspected of having RA-ILD will undergo TUS as index test performed by a junior resident in rheumatology (BKS), who is certified by the European Respiratory Society in performing TUS assessments. Participants form a consecutive series of up to 80 individuals in total. The anonymised TUS images will be stored and scored by the junior resident as well as two senior rheumatologists, who have received training in TUS, and a TUS-experienced pulmonologist. HRCT will be used as the gold standard for ILD diagnosis (reference standard). The two basic measures for quantifying the diagnostic test accuracy of the TUS test are the sensitivity and specificity in comparison to the HRCT.Ethics and dissemination Data will be collected and stored in the Research Electronic Data Capture database. The study is approved by the Committees on Health Research Ethics and the Danish Data Protection Agency. The project is registered at clinicaltrials.gov (NCT05396469, pre-results) and data will be published in peer-reviewed journals
    corecore