377 research outputs found

    Impact of the patient’s body position on the intraabdominal workspace during laparoscopic surgery

    Get PDF
    BACKGROUND: The effects of the patient's body position on the intraabdominal workspace in laparoscopic surgery were analyzed. METHODS: The inflated volume of carbon dioxide was measured after insufflation to a preset pressure of 15 mmHg for 20 patients with a body mass index (BMI) greater than 35 kg/m(2). The patients were anesthetized with full muscle relaxation. The five positions were (1) table horizontal with the legs flat (supine position), (2) table in 20 degrees reverse Trendelenburg with the legs flat, (3) table in 20 degrees reverse Trendelenburg with the legs flexed 45 degrees upward at the hips (beach chair position), (4) table horizontal with the legs flexed 45 degrees upward at the hips, and (5) table in 20 degrees Trendelenburg with the legs flat. The positions were performed in a random order, and the first position was repeated after the last measurement. Repeated measure analysis of variance was used to compare inflated volumes among the five positions. RESULTS: A significant difference in inflated volume was found between the five body positions (P = 0.042). Compared with the mean inflated volume for the supine position (3.22 +/- 0.78 l), the mean inflated volume increased by 900 ml for the Trendelenburg position or when the legs were flexed at the hips, and decreased by 230 ml for the reverse Trendelenburg position. CONCLUSIONS: The Trendelenburg position for lower abdominal surgery and reverse Trendelenburg with flexing of the legs at the hips for upper abdominal surgery effectively improved the workspace in obese patients, even with full muscle relaxation.status: publishe

    Ideal versus corrected body weight for dosage of sugammadex in morbidly obese patients

    Get PDF
    Summary To date, the dosing of sugammadex is based on real body weight without taking fat content into account. We compared the reversal of profound rocuronium-induced neuromuscular blockade in morbidly obese patients using doses of sugammadex based on four different weight corrections. One hundred morbidly obese patients, scheduled for laparoscopic bariatric surgery under propofolsufentanil anaesthesia, were randomly assigned four groups: ideal body weight; ideal body weight + 20%; ideal body weight + 40%; and real body weight. Patients received sugammadex 2 mg.k

    In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The per-operative assessment of primary stem stability may help to improve the performance of total hip replacement. Vibration analysis methods have been successfully used to assess dental implant stability, to monitor fracture healing and to measure bone mechanical properties. The objective of the present study was to evaluate in vivo a vibration analysis-based endpoint criterion for the insertion of the stem by successive surgeon-controlled hammer blows.</p> <p>Methods</p> <p>A protocol using a vibration analysis technique for the characterisation of the primary bone-prosthesis stability was tested in 83 patients receiving a custom-made, intra-operatively manufactured stem prosthesis. Two groups were studied: one (n = 30) with non cemented and one (n = 53) with partially cemented stem fixation. Frequency response functions of the stem-femur system corresponding to successive insertion stages were compared.</p> <p>Results</p> <p>The correlation coefficient between the last two frequency response function curves was above 0.99 in 86.7% of the non cemented cases. Lower values of the final correlation coefficient and deviations in the frequency response pattern were associated with instability or impending bone fracture. In the cases with a partially cemented stem an important difference in frequency response function between the final stage of non cemented trial insertion and the final cemented stage was found in 84.9% of the cases. Furthermore, the frequency response function varied with the degree of cement curing.</p> <p>Conclusion</p> <p>The frequency response function change provides reliable information regarding the stability evolution of the stem-femur system during the insertion. The protocol described in this paper can be used to accurately detect the insertion end point and to reduce the risk for intra-operative fracture.</p

    Laparoscopic adjustable banded roux-en-y gastric bypass as a primary procedure for the super-super-obese (body mass index > 60 kg/m2)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Currently, there is no consensus opinion regarding the optimal procedure of choice in super-super-morbid obesity (Body mass index, BMI > 60 kg/m2). Roux-en-Y gastric bypass (RYGB) is associated with failure to achieve or maintain 50% excess weight loss (EWL) or BMI < 35 in approximately 15% of patients. Also, percent EWL is significantly less after 1-year in the super-super-obese group as compared with the less obese group and many patients are still technically considered to be obese (lowest post-surgical BMI > 35) following RYGB surgery in this group. The addition of adjustable gastric band (AGB) to RYGB has been reported as a revisional procedure but this combined bariatric procedure has not been explored as a primary operation.</p> <p>Methods</p> <p>In a primary laparoscopic RYGB, an AGB is drawn around the gastric pouch through a small opening between the blood vessels on the lesser curve and the gastric pouch. The band is then fixed by suturing the gastric remnant to the gastric pouch both above and below the band to prevent slippage.</p> <p>Results</p> <p>Between November 2009 and March 2010, 6 consecutive super-super-obese patients underwent a primary laparoscopic adjustable banded Roux-en-Y gastric bypass procedure at our institution. One male patient (21 years, BMI 70 kg/m²) developed a pneumonia postoperatively. No other postoperative complications were observed.</p> <p>Conclusion</p> <p>To the best of our knowledge, this is the first series of patients that underwent a laparoscopic adjustable banded RYGB as a primary operation for the super-super obese in the indexed literature. With the combined procedure, a sequential action mechanism for weight loss is to be expected. The restrictive, malabsorptive and hormonal working mechanism of the RYGB will induce weight loss from the start reaching a stabilised plateau of weight after 12 - 18 months. At that time, filling of the band can be started resulting in further gastric pouch restriction and increased weight loss. Moreover, besides improving the results of total weight loss, a gradual filling of the band can as well prevent the RYGB patient from weight regain if restriction would fade away with time.</p
    • …
    corecore