10 research outputs found

    Visual-motor involvement in autism spectrum disorder: could the stereopsis deficit affect motor coordination?

    Get PDF
    PurposeGiven the known difficulty in sensory processing and in motor skills in patients with Autism Spectrum Disorder (ASD), and since visual impairment could interfere with children’s behaviour, early detection and management of visual-motor difficulties are crucial. This exploratory study aims to evaluate the visual-motor status in a cohort of children affected by ASD.MethodsThe records of patients affected by ASD and admitted between 2018 and 2022 to the Pediatric University Hospital of Verona were reviewed. Best Corrected Visual Acuity, cycloplegic refraction, stereopsis, convergence, complete ocular motility, strabismus examination, slit-lamp anterior segment examination and fundus ophthalmoscopy were collected and reviewed.ResultsA total of 253 patients (203 ASD and 50 healthy controls) were included in the study. A higher number of total orthoptic defects were detected in the ASD group, in comparison with the control group. Specifically, a higher percentage of stereopsis deficit and convergence insufficiency was observed.ConclusionIn our cohort of children with ASD stereopsis deficit, convergence insufficiency and refractive errors are the most observed ocular conditions. These findings are consistent with the known alterations of motor skills and sensory processing in ASD. Moreover, our study supports the hypothesis that visual acuity is not compromised in children with ASD. As a result, a complete ophthalmic evaluation is highly recommended in children with ASD, to guarantee early detection and treatment of possible visual-motor defects

    Comparison of dynamic contour tonometry and Goldmann applanation tonometry in deep lamellar and penetrating keratoplasties

    No full text
    PURPOSE: To compare the measurements of intraocular pressure (IOP) with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in eyes with corneal graft and to evaluate the influence of corneal thickness (CCT), corneal curvature (CC), and astigmatism on these methods. DESIGN: Prospective, observational cross-sectional study. METHODS: Eighteen eyes of 18 patients after penetrating keratoplasty (PKP) and 14 eyes of 14 patients after deep lamellar keratoplasty (DLKP) underwent IOP evaluation with DCT and GAT, and measurements of CCT, CC, and astigmatism. Bland-Altman plots were used to evaluate the agreement between tonometers. Multivariate regression analysis was used to evaluate the influence of ocular structural factors and running suture on IOP measurements obtained with both tonometers. RESULTS: IOP values obtained by DCT and GAT were strongly correlated in all eyes (r = .91; P < .001). DCT values measured 2.5 +/- 1.7 mm Hg higher than GAT readings (P < .001). A reduction of the mean IOP difference between DCT and GAT with an increase in IOP values (P < .001) was found. Regression analysis showed no effect of CCT, CC, astigmatism, and running suture on both DCT and GAT readings, either in DLKP or in PKP eyes. CONCLUSIONS: We found a good overall correlation between both tonometers but the agreement between instruments differs in high or low IOP ranges. The wide and varying 95% limits of agreement between DCT and GAT indicates that DCT provides IOP measurements on deep lamellar and penetrating keratoplasties which can be used in the clinical practice

    The nerve fibre layer in ocular hypertension. Preliminary results

    No full text
    A group of healthy subjects (IOP < 22 mmHg) and a simple ocular hypertension group (IOP > or = 22 mmHg) were examined with a view to checking if there were any differences between their nerve fibre layers. Results indicate thinner fibres in the ocular hypertensives significantly correlative with pressure increase. Among the two groups, some corresponding fibre thicknesses were found

    Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes.

    No full text
    Purpose: To compare the measurements of intraocular pressure (IOP) with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in healthy and glaucomatous eyes and to evaluate the influence of corneal thickness (CCT), corneal curvature (CC), axial length (AL), and age on these tonometric alternatives.Methods: Three hundred eyes of 100 healthy subjects, 100 patients with primary open angle glaucoma, and 100 patients with primary angle-closure glaucoma underwent IOP evaluation with DCT and GAT, and measurements of CCT, CC, and AL. Bland-Altman plots were used to evaluate the agreement between tonometers. Regression analysis was used to evaluate the influence of ocular structural factors on IOP measurements obtained with both tonometers.Results: Bland-Altman plots indicated that the 95\% limits of agreement between tonometers were -1.4 to 6.6 mmHg. DCT values measured 2.6+/-1.9 mmHg higher than GAT readings (P<0.001). The mean IOP difference between DCT and GAT (DeltaIOP) was higher in healthy than in glaucomatous eyes and the magnitude of difference increased with increasing CCT. A significant reduction of DeltaIOP with an increase in both CCT (P<0.001) and IOP values (P<0.001) was found. Regression analysis showed no effect of CC, AL, and age on both DCT and GAT readings. In contrast to GAT (P<0.001), DCT measurements were not influenced by CCT (P=0.43).ConclusionsIOP readings obtained by DCT were higher and less affected by CCT than those by GAT. The DeltaIOP was higher in healthy than in glaucomatous eyes and decreased in relation to increased CCT and IOP values.CONCLUSIONS: IOP readings obtained by DCT were higher and less affected by CCT than those by GAT. The DeltaIOP was higher in healthy than in glaucomatous eyes and decreased in relation to increased CCT and IOP values

    Visual field defects and normal nerve fiber layer: may they coexist in primary open-angle glaucoma?

    No full text
    The retinal nerve fiber layer (RNFL) is the anatomical structure most sensitive to glaucoma injury. Before a functional loss such as a visual field defect is displayed, a large number of nerve fibers can be damaged. However, there are glaucoma patients in which an apparently normal RNFL coexists with evident visual field defects. A total of 54 eyes affected with primary open-angle glaucoma were studied. Visual field was examined with the Humphrey Field Analyzer (Zeiss) using program 30-2. The Nerve Fiber Analyzer II (Laser Diagnostic Technologies) was used to study the RNFL of these patients. Mean deviation of the visual field ranged from 6 to 31 dB in all eyes that were examined. The average thickness of the RNFL ranged from 20 to 90 microm. According to our previous experience 75 microm was fixed as the cutoff between normal and pathological values of RNFL thickness. We identified 5 eyes with a RNFL thickness over 75 microm and a visual field with a mean deviation over 6 dB; 9% of the studied eyes were found to have a visual field defect with no changes in RNFL. We conclude that not all subjects have the same number of fibers at birth and that it is therefore possible to underestimate the RNFL changes. Our study illustrates that the concept of normal and altered has to be considered as a relative one for all the aspects characterizing the glaucomatous disease

    Ultrasound biomicroscopy and intraocular-pressure-lowering mechanisms of deep sclerectomy with reticulated hyaluronic acid implant

    No full text
    Purpose: To evaluate the anatomic characteristics and intraocular pressure (IOP) lowering mechanisms of deep sclerectomy with reticulated hyaluronic acid implant (DS with RHAI) using ultrasound biomicroscopy (UBM). Setting: Eye Clinic, Department of Neurological and Vision Sciences, University of Verona, Verona, Italy. Methods: Thirty patients with primary open-angle glaucoma not controlled by medical therapy had DS with RHAI in 1 eye. A complete ocular examination and UBM study were performed 1, 3, 6, and 12 months postoperatively and thereafter at 6 month intervals. Eleven parameters were evaluated, the most important of which were IOP, surgical success in lowering IOP to 21 mm Hg or less with or without additional medical therapy, UBM appearance of the site of DS with RHAI, size of the decompression space, presence of a filtering bleb and supraciliary hypoechoic area, and scleral reflectivity around the decompression space. Results: After a mean follow-up of 11.4 months +/- 4.7 (SD), the mean percentage reduction in IOP compared to preoperatively was 38% (from 26 +/- 4.5 mm Hg to 16.2 +/- 3.8 mm Hg; P =.0001), Twenty-four patients (80%) had an]OP less than 21 mm Hg; however, 7 of these eyes (23%) required additional IOP-lowering medical therapy. The operation failed in 6 patients (20%) despite additional therapy. Ultrasound biomicroscopy revealed a reduction in the size of the decompression space from 6 months postoperatively and its disappearance in 2 cases, The difference in size at the last follow-up and at 1 month postoperatively (maximum length 2.41 +/- 1.02 mm versus 3.53 +/- 0.51 mm) was significant(P =.0001).At the last examination, a filtering bleb was present in 18 patients (60%), a supraciliary hypoechoic area in 18(60%), and hyporeflectivity of the scleral tissue around the decompression space in 14 (47%). These 3 UBM characteristics were detected singly and in various combinations. The simultaneous presence of all 3 characteristics in the same eye correlated significantly with a higher surgical success rate (P =.004). Conclusions: Ultrasound biomicroscopy showed that filtering bleb formation was frequent in eyes having DS with RHAI but that it was not the only surgically induced IOP-lowering mechanism, increased uveoscleral and transscleral filtration may be equally important

    Bilateral angle-closure during hospitalization for coronavirus disease-19 (COVID-19): A case report

    No full text
    Purpose: This report describes a case of bilateral primary angle closure (PAC) progressing to unilateral end-stage primary angle closure glaucoma (PACG) associated with treatment for coronavirus disease-19 (COVID-19) infection. Methods: A 64-year-old man came to our attention because of blurred vision after a 2-month hospital stay for treatment of COVID-19 infection. Examination findings revealed PACG, with severe visual impairment in the right eye and PAC in the left eye due to plateau iris syndrome. The patient's severe clinical condition and prolonged systemic therapy masked the symptoms and delayed the diagnosis. Medical chart review disclosed the multifactorial causes of the visual impairment. Ultrasound biomicroscopy (UBM) aided in diagnosis and subsequent therapy. Results: The cause behind the primary angle closure and the iridotrabecular contact was eliminated by bilateral cataract extraction, goniosynechialysis, and myotic therapy. Conclusions: COVID-19 treatment may pose an increased risk for PAC. Accurate recording of patient and family ophthalmic history is essential to prevent its onset. Recognition of early signs of PAC is key to averting its progression to PACG

    Vascular risk factors for primary open angle glaucoma: the Egna-Neumarkt study

    No full text
    OBJECTIVE: To assess the impact of vascular risk factors on the prevalence of primary open angle glaucoma. DESIGN: Population-based cross-sectional study. PARTICIPANTS: Four thousand two hundred ninety-seven patients more than 40 years of age underwent a complete ocular examination in the context of the Egna-Neumarkt Glaucoma Study. INTERVENTION: Ocular examinations were performed by trained, quality-controlled ophthalmologists according to a predefined standardized protocol including medical interview, blood pressure reading, applanation tonometry, computerized perimetry, and optic nerve head examination. MAIN OUTCOME MEASURES: Prevalences of ocular hypertension, primary open-angle glaucoma, normal-tension glaucoma, and other types of glaucoma were determined. Correlation coefficients were calculated for the association between systemic blood pressure and age-adjusted intraocular pressure (IOP) and between age and both intraocular and systemic blood pressures. Odds ratios were computed to assess the risk of primary open-angle glaucoma and normal-tension glaucoma in relation to systemic hypertension or antihypertensive medication, blood pressure levels, diastolic perfusion pressure, and a number of other cardiovascular risk factors. RESULTS: A positive correlation was found between systemic blood pressure and IOP, and an association was found between diagnosis of primary open-angle glaucoma and systemic hypertension. Lower diastolic perfusion pressure is associated with a marked, progressive increase in the frequency of hypertensive glaucoma. No relationship was found between systemic diseases of vascular origin and glaucoma. CONCLUSIONS: Our data are in line with those reported in other recent epidemiologic studies and show that reduced diastolic perfusion pressure is an important risk factor for primary open-angle glaucoma

    Does Nerve fiber layer Thickness correlate with visula field defects in glaucoma? A study with nerve fiber analyzer

    No full text
    The Nerve Fiber Analyzer, a confocal scanning laser ophthalmoscope, was used to measure the thickness of the retinal nerve fiber layer (NFL) in a glaucoma population. The authors studied the correlation between NFL thickness and the perimetric defects. The NFL was found to be statistically thinner in comparison to a normal control group of subjects. The correlation between the perimetric index MD and the NFA was statistically significant only for the lower quadrant of retinal NFL. The correspondence between thinner NFL and perimetric defects was investigated

    Comparison between Fundus Automated Perimetry and Humphrey Field Analyzer: performance and usability of the Fundus Automated Perimetry and Humphrey Field Analyzer in healthy, ocular hypertensive, and glaucomatous patients

    No full text
    Purpose: We compared the performance and usability of the Fundus Automated Perimetry (FAP) and Humphrey Field Analyzer (HFA) in patients with glaucoma, ocular hypertension, and healthy subjects. Materials and methods: A total of 60 participants, divided in three groups of 20, glaucoma (POAG), ocular hypertension (OHT), and controls group, underwent a HFA test 24-2 SITA standard and a FAP test 24-2 ZEST sequence, in randomized order. The mean differences between perimeters of mean deviation (MD), pattern standard deviation (PSD) were correlated using the t-test and the Bland-Altman plot while execution time, Glaucoma Staging System 2 (GSS2), Hodapp-Parrish-Anderson staging system, localization of the defect, false positives (FP), and false negatives (FN) were compared with t-test analysis. Usability was measured through answers of a dedicated questionnaire. Results: MD's difference was higher for FAP than HFA: OHT -2.20 \ub1 1.33 dB (p &lt; 0.001), POAG -2.00 \ub1 1.66 dB (p &lt; 0.001), and controls -1.08 \ub1 1.43 dB (p &lt; 0.001). PSD's difference was higher for FAP than HFA: OHT 0.85 \ub1 1.16 dB (p &lt; 0.001), POAG 0.78 \ub1 2.32 dB (p = 0.043), and controls 0.49 \ub1 1.15 dB (p &lt; 0.001). GSS2's difference showed that FAP found more severe defects than HFA. Exams duration was longer for FAP versus HFA: in OHT 363 s versus 301 s, in POAG 494 s versus 362 s, and in controls 360 s versus 277 s. For FN and FP, there were no statistically significant differences. The 77% of all subjects preferred FAP to HFA test. Conclusion: Considering MD and GSS2 classification, FAP finds more severe defects. Moreover, although FAP duration is longer, this method is preferred by most of the patients
    corecore