    Associations between age and sleep apnea risk among newborn infants

    Full text link
    ObjectiveAmong older children, sleep‐disordered breathing (SDB) is associated with measurable neurocognitive consequences. However, diagnostic SDB thresholds are lacking for infants < 12 months. We sought to evaluate the relationship between SDB indices, gestational age (GA), and postmenstrual age (PMA) for infants who underwent clinically‐indicated polysomnograms at a tertiary care center.MethodsEvery infant < 3‐months chronological age whose first clinically‐indicated polysomnogram was between 2/2012 and 2/2017 was included. Linear regression was used to evaluate associations between apnea‐hypopnea index (AHI), obstructive‐apnea index (OAI), and GA and PMA for infants with and without obvious clinical risk factors for SDB (eg, micrognathia and cleft palate).ResultsFor 53 infants without obvious SDB risk factors (GA 35.6 ± 4.5 weeks; PMA 41.2 ± 4.0 weeks), mean AHI was 27 ± 18 and OAI 2.9 ± 4.5. There was a weak inverse relationship between AHI and PMA (r2 = 0.12, P = 0.01), but AHI was not predicted by GA (r2 = 0.04, P = 0.13). Conversely, OAI was more strongly associated with GA (r2 = 0.33, P < 0.0001) than PMA (r2 = 0.08, P = 0.036). For 28 infants with congenital structural anomalies that predispose to SDB (GA 38.0 ± 3.1 weeks, PMA 43.1 ± 3.3 weeks, AHI 37.7 ± 30, OAI 8.2 ± 11.8), neither AHI nor OAI were related to PMA or GA.ConclusionsAmong infants who received clinically‐indicated polysomnograms but did not have obvious structural risk for SDB, AHI declined with advancing PMA, but obstructive‐apnea was best predicted by prematurity. In contrast, the SDB risk did not improve with increasing GA or PMA for infants with congenital structural risk factors; such infants may not outgrow their risk for SDB.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/150552/1/ppul24354_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/150552/2/ppul24354.pd

    Impact of Lack of Breast Feeding during Neonatal Age on the Development of Clinical Signs of Pneumonia and Hypoxemia in Young Infants with Diarrhea

    Get PDF
    Hypoxemia is a grave sequel of pneumonia, and an important predictor of a fatal outcome. Pneumonia in the neonatal period is often associated with lack of breast feeding. However, there is no published report on the impact of the cessation of breast feeding in the neonatal period on the development of pneumonia and hypoxemia. The purpose of our study was to assess the impact of non-breast feeding or stopping breast feeding during the neonatal period (henceforth to be referred to as non-breast fed) on clinical features of pneumonia and hypoxemia in 0-6-month-old infants with diarrhea admitted to an urban hospital in Bangladesh.We prospectively enrolled all infants (n = 107) aged 0 to 6 months who were admitted to the Special Care Ward (SCW) of the Dhaka Hospital of the International Centre for Diarrhoeal Disease Research Bangladesh (ICDDR,B) with diarrhea and pneumonia from September 2007 through December 2007.We compared the clinical features of pneumonia and hypoxemia of breast fed infants (n = 34) with those who were non-breast fed (n = 73).The median (inter-quartile range) duration of hypoxemia (hours) in non-breast-feds was longer than breast-fed infants [0.0 (0.0, 12.0) vs. 12.0 (0.0, 21.75); p = 0.021]. After adjusting for potential confounders such as inability to drink, fever, head nodding, cyanosis, grunting respiration, and lower chest wall in drawing, the non-breast-fed infants with pneumonia along with diarrhea had a higher probability of cough (OR 9.09; CI 1.34-61.71; p = 0.024), hypoxemia (OR 3.32; CI 1.23-8.93; p = 0.017), and severe undernutrition (OR 3.42; CI 1.29-9.12; p = 0.014).Non-breast feeding or cessation of breast feeding during the neonatal period may substantially increase the incidence of severe malnutrition, incidence of cough, and both the incidence and duration of hypoxemia in young infants presenting with pneumonia and diarrhea. The findings emphasize the paramount importance of the continuation of breast feeding in the neonatal period and early infancy

    Endothelial dysfunction in obese non-hypertensive children without evidence of sleep disordered breathing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Endothelial dysfunction is a complication of both obesity and obstructive sleep apnea syndrome (OSAS), the latter being highly prevalent among obese children. It is unknown whether obesity causes endothelial dysfunction in children in the absence of OSAS. This study examines endothelial function in obese and non-obese children without OSAS.</p> <p>Methods</p> <p>Pre-pubertal non-hypertensive children were recruited. Endothelial function was assessed in a morning fasted state, using a modified hyperemic test involving cuff-induced occlusion of the radial and ulnar arteries. The absence of OSAS was confirmed by overnight polysomnography. Anthropometry was also performed.</p> <p>Results</p> <p>55 obese children (mean age 8.6 ± 1.4 years, mean BMI z-score: 2.3 ± 0.3) were compared to 50 non-obese children (mean age 8.0 ± 1.6 years, mean BMI z-score 0.3 ± 0.9). Significant delays to peak capillary reperfusion after occlusion release occurred in obese compared to non-obese children (45.3 ± 21.9 sec <it>vs</it>. 31.5 ± 14.1 sec, p < 0.01), but no differences in the magnitude of hyperemia emerged. Time to peak reperfusion and percentage of body fat were positively correlated (r = 0.365, p < 0.01).</p> <p>Conclusions</p> <p>Our findings confirm that endothelial dysfunction occurs early in life in obese children, even in the absence of OSAS. Thus, mechanisms underlying endothelial dysfunction in pediatric obesity are operational in the absence of sleep-disordered breathing.</p

    Systematic review of the validity and reliability of consumer-wearable activity trackers

    Get PDF
    Abstract Background Consumer-wearable activity trackers are electronic devices used for monitoring fitness- and other health-related metrics. The purpose of this systematic review was to summarize the evidence for validity and reliability of popular consumer-wearable activity trackers (Fitbit and Jawbone) and their ability to estimate steps, distance, physical activity, energy expenditure, and sleep. Methods Searches included only full-length English language studies published in PubMed, Embase, SPORTDiscus, and Google Scholar through July 31, 2015. Two people reviewed and abstracted each included study. Results In total, 22 studies were included in the review (20 on adults, 2 on youth). For laboratory-based studies using step counting or accelerometer steps, the correlation with tracker-assessed steps was high for both Fitbit and Jawbone (Pearson or intraclass correlation coefficients (CC) > =0.80). Only one study assessed distance for the Fitbit, finding an over-estimate at slower speeds and under-estimate at faster speeds. Two field-based studies compared accelerometry-assessed physical activity to the trackers, with one study finding higher correlation (Spearman CC 0.86, Fitbit) while another study found a wide range in correlation (intraclass CC 0.36–0.70, Fitbit and Jawbone). Using several different comparison measures (indirect and direct calorimetry, accelerometry, self-report), energy expenditure was more often under-estimated by either tracker. Total sleep time and sleep efficiency were over-estimated and wake after sleep onset was under-estimated comparing metrics from polysomnography to either tracker using a normal mode setting. No studies of intradevice reliability were found. Interdevice reliability was reported on seven studies using the Fitbit, but none for the Jawbone. Walking- and running-based Fitbit trials indicated consistently high interdevice reliability for steps (Pearson and intraclass CC 0.76–1.00), distance (intraclass CC 0.90–0.99), and energy expenditure (Pearson and intraclass CC 0.71–0.97). When wearing two Fitbits while sleeping, consistency between the devices was high. Conclusion This systematic review indicated higher validity of steps, few studies on distance and physical activity, and lower validity for energy expenditure and sleep. The evidence reviewed indicated high interdevice reliability for steps, distance, energy expenditure, and sleep for certain Fitbit models. As new activity trackers and features are introduced to the market, documentation of the measurement properties can guide their use in research settings