5 research outputs found

    A Phase II trial of Higher RadiOtherapy Dose In The Eradication of early rectal cancer (APHRODITE): protocol for a multicentre, open-label randomised controlled trial.

    Get PDF
    INTRODUCTION The standard of care for patients with localised rectal cancer is radical surgery, often combined with preoperative neoadjuvant (chemo)radiotherapy. While oncologically effective, this treatment strategy is associated with operative mortality risks, significant morbidity and stoma formation. An alternative approach is chemoradiotherapy to try to achieve a sustained clinical complete response (cCR). This non-surgical management can be attractive, particularly for patients at high risk of surgical complications. Modern radiotherapy techniques allow increased treatment conformality, enabling increased radiation dose to the tumour while reducing dose to normal tissue. The objective of this trial is to assess if radiotherapy dose escalation increases the cCR rate, with acceptable toxicity, for treatment of patients with early rectal cancer unsuitable for radical surgery. METHODS AND ANALYSIS APHRODITE (A Phase II trial of Higher RadiOtherapy Dose In The Eradication of early rectal cancer) is a multicentre, open-label randomised controlled phase II trial aiming to recruit 104 participants from 10 to 12 UK sites. Participants will be allocated with a 2:1 ratio of intervention:control. The intervention is escalated dose radiotherapy (62 Gy to primary tumour, 50.4 Gy to surrounding mesorectum in 28 fractions) using simultaneous integrated boost. The control arm will receive 50.4 Gy to the primary tumour and surrounding mesorectum. Both arms will use intensity-modulated radiotherapy and daily image guidance, combined with concurrent chemotherapy (capecitabine, 5-fluorouracil/leucovorin or omitted). The primary endpoint is the proportion of participants with cCR at 6 months after start of treatment. Secondary outcomes include early and late toxicities, time to stoma formation, overall survival and patient-reported outcomes (European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaires QLQ-C30 and QLQ-CR29, low anterior resection syndrome (LARS) questionnaire). ETHICS AND DISSEMINATION The trial obtained ethical approval from North West Greater Manchester East Research Ethics Committee (reference number 19/NW/0565) and is funded by Yorkshire Cancer Research. The final trial results will be published in peer-reviewed journals and adhere to International Committee of Medical Journal Editors guidelines. TRIAL REGISTRATION NUMBER ISRCTN16158514

    Dose-escalated simultaneous integrated boost radiotherapy in early breast cancer (IMPORT HIGH): a multicentre, phase 3, non-inferiority, open-label, randomised controlled trial.

    No full text
    A tumour-bed boost delivered after whole-breast radiotherapy increases local cancer-control rates but requires more patient visits and can increase breast hardness. IMPORT HIGH tested simultaneous integrated boost against sequential boost with the aim of reducing treatment duration while maintaining excellent local control and similar or reduced toxicity. IMPORT HIGH is a phase 3, non-inferiority, open-label, randomised controlled trial that recruited women after breast-conserving surgery for pT1-3pN0-3aM0 invasive carcinoma from radiotherapy and referral centres in the UK. Patients were randomly allocated to receive one of three treatments in a 1:1:1 ratio, with computer-generated random permuted blocks used to stratify patients by centre. The control group received 40 Gy in 15 fractions to the whole breast and 16 Gy in 8 fractions sequential photon tumour-bed boost. Test group 1 received 36 Gy in 15 fractions to the whole breast, 40 Gy in 15 fractions to the partial breast, and 48 Gy in 15 fractions concomitant photon boost to the tumour-bed volume. Test group 2 received 36 Gy in 15 fractions to the whole breast, 40 Gy in 15 fractions to the partial breast, and 53 Gy in 15 fractions concomitant photon boost to the tumour-bed volume. The boost clinical target volume was the clip-defined tumour bed. Patients and clinicians were not masked to treatment allocation. The primary endpoint was ipsilateral breast tumour relapse (IBTR) analysed by intention to treat; assuming 5% 5-year incidence with the control group, non-inferiority was predefined as 3% or less absolute excess in the test groups (upper limit of two-sided 95% CI). Adverse events were assessed by clinicians, patients, and photographs. This trial is registered with the ISRCTN registry, ISRCTN47437448, and is closed to new participants. Between March 4, 2009, and Sept 16, 2015, 2617 patients were recruited. 871 individuals were assigned to the control group, 874 to test group 1, and 872 to test group 2. Median boost clinical target volume was 13 cm (IQR 7 to 22). At a median follow-up of 74 months there were 76 IBTR events (20 for the control group, 21 for test group 1, and 35 for test group 2). 5-year IBTR incidence was 1路9% (95% CI 1路2 to 3路1) for the control group, 2路0% (1路2 to 3路2) for test group 1, and 3路2% (2路2 to 4路7) for test group 2. The estimated absolute differences versus the control group were 0路1% (-0路8 to 1路7) for test group 1 and 1路4% (0路03 to 3路8) for test group 2. The upper confidence limit for test group 1 versus the control group indicated non-inferiority for 48 Gy. Cumulative 5-year incidence of clinician-reported moderate or marked breast induration was 11路5% for the control group, 10路6% for test group 1 (p=0路40 vs control group), and 15路5% for test group 2 (p=0路015 vs control group). In all groups 5-year IBTR incidence was lower than the 5% originally expected regardless of boost sequencing. Dose-escalation is not advantageous. 5-year moderate or marked adverse event rates were low using small boost volumes. Simultaneous integrated boost in IMPORT HIGH was safe and reduced patient visits. Cancer Research UK. [Abstract copyright: Copyright 漏 2023 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.
    corecore