4 research outputs found

    Investigation of biomechanical and biosafety of injection moulded implant materials

    Get PDF
    This paper presents the attempt to manufacture metallic implant using medical grade 316L stainless steel alloy powder by MIM process. The powder with the median particle size of 15 ฮผm and a binder consisting of palm stearin and poly ethylene were mixed at 160ยฐC using a sigmablade mixer for one hour to prepare the feedstock of the test bar. The rheological properties of the feedstock was tested using capillary rheometer. The test bar was injection moulded using vertical injection moulding machine with the nozzle temperature of 200ยฐC. Prior to sintering, the specimens were debound using a combination of solvent extraction and thermal pyrolysis method. The specimens were then sintered under vacuum at the temperature between 1300oC to 1360oC. The properties of the sintered bar such as physical appearance and densities were presented and discussed. The biocompatibility including toxicity properties of the implant also been presented. The results showed that physical and mechanical properties of the sintered sample complied with the international standard ยฉ (2014) Trans Tech Publications, Switzerland

    Metal injection moulding of hip stem CoCrMo alloy powder using palm stearin binder system

    No full text
    Metal Injection Moulding (MIM) has undergone development of various binder systems with the aims of shortening the overall debinding time duration. In the present work, binder system based on biopolymer has been utilised in injection moulding of hip stem CoCrMo alloy powder. The feedstock consisted of CoCrMo powder with mean diameter particle size of 16 ฮผm and binder which comprised of major fraction of wax and minor fraction of polyethylene. The moulded part was immersed into n-heptane at 60 ยฐC in order to remove the palm stearin, followed by sintering in a controlled vacuum atmosphere. Results showed that solvent extraction debinding technique allowed complete removal of palm stearin from the injection moulded part within 5 hours without swelling or distortion of the debound part. Lower heating rate is needed during thermal pyrolysis in order to retain the shape due to the thickness of the part

    Physical and mechanical properties of injection molded co-cr-mo alloy powder for orthopedic applications

    No full text
    Cobalt-chromium alloys are commonly used for surgical implants because of their high strength, superior corrosion resistance, non-magnetic behavior, and biocompatibility. Cobalt- Chromium-Molybdenum (Co-Cr-Mo) applications include prosthetic replacements of hips. This paper presents the attempt to produce metallic implant using Co-Cr-Mo powder by MIM process, focusing on the effects of different heating rate during sintering process at 1380 oC. Co-Cr-Mo powder was mixed homogeneously with palm oil based binder with powder loading of 65 vol% and was injection molded using vertical injection molding machine with the nozzle temperature of 160 ยฐC to produce green compacts. The binders were then removed by solvent extraction process and sintered in vacuum condition at 10-5 mbar at 1380 ยฐC. Results indicated that sintered density and tensile strength varies from 8.1 g/cm3 to 8.2 g/cm3 and 546 MPa to 797 MPa respectively. The mechanical properties comply with the international standard (ASTM F75)
    corecore