2 research outputs found

    Bio-energy generation in an affordable, single-chamber microbial fuel cell integrated with adsorption hybrid system: effects of temperature and comparison study

    Get PDF
    A microbial fuel cell (MFC) integrated with adsorption system (MFC-AHS) is tested under various operating temperatures with palm oil mill effluent as the substrate. The optimum operating temperature for such system is found to be at ∼35°C with current, power density, internal resistance (Rin), Coulombic efficiency (CE) and maximum chemical oxygen demand (COD) removal of 2.51 ± 0.2 mA, 74 ± 6 mW m−3, 25.4 Ω, 10.65 ± 0.5% and 93.57 ± 1.2%, respectively. Maximum current density increases linearly with temperature at a rate of 0.1772 mA m−2 °C−1, whereas maximum power density was in a polynomial function. The temperature coefficient (Q10) is found to be 1.20 between 15°C and 35°C. Present studies have demonstrated better CE performance when compared to other MFC-AHSs. Generally, MFC-AHS has demonstrated higher COD removals when compared to standalone MFC regardless of operating temperatures. Abbreviations: ACFF: activated carbon fiber felt; APHA: American Public Health Association; CE: Coulombic efficiency; COD: chemical oxygen demand; ECG: electrocardiogram; GAC: granular activated carbon; GFB: graphite fiber brush; MFC: microbial fuel cell; MFC-AHS: microbial fuel cell integrated with adsorption hybrid system; MFC-GG: microbial fuel cell integrated with graphite granules; POME: palm oil mill effluent; PTFE: polytetrafluoroethylene; SEM: scanning electron microscope. © 2017 Informa UK Limited, trading as Taylor & Francis Group

    Effects of temperature on wastewater treatment in an affordable microbial fuel cell-adsorption hybrid system

    Get PDF
    Graphical abstract: A cost effective single-chamber microbial fuel cell (MFC) integrated with adsorption system was tested under different operating temperatures to observe pH profiles, organics, solids, nutrients, color and turbidity removal and power density generation. The optimum operating temperature range was found to be ∼25-35°C with majority of the removals achieved at ∼35°C. Maximum power density recorded was 74±6mW/m3 with coulombic efficiency (CE) of 10.65±0.5% when operated at 35°C. Present studies had successfully demonstrated the effectiveness of a hybrid system in removing various types of pollutants in POME at optimum temperature and able to fulfill the stringent effluent discharge limit. Chemical oxygen demand (COD), total solids (TS) and turbidity removals increase linearly with temperatures with removal efficiency of 0.5889%C−1, 1.0754%C−1 and 0.7761%C−1, respectively. The temperature coefficient (Q10) is found to be 1.06, 1.45 and 1.09, respectively. Besides, MFC-adsorption hybrid system had demonstrated superior stability over a wide range of operating temperatures in terms of COD removal as compared to the non-integrated MFC system
    corecore