40 research outputs found

    Thresholds for the Oxford Hip Score after total hip replacement surgery:a novel approach to postoperative evaluation

    Get PDF
    Abstract Background This is a prospective cohort study to define the thresholds to distinguish patients with a satisfactory or unsatisfactory outcome after total hip replacement (THR) based on patient-reported outcome measures (PROMs) including the Oxford Hip Score (OHS), and using patient satisfaction and patient-perceived function as global transition items. The thresholds are intended to be used as a tool in the process of determining which patients are in need of postoperative outpatient evaluation. Methods One hundred and three THR patients who had completed a preoperative questionnaire containing the OHS questionnaire were invited to complete the same questionnaire and supplementary questions at a mean of 6 (4–9) months after surgery. Correlations between outcome measures and anchors were calculated using Pearson’s correlation coefficient. Thresholds were established by receiver operating characteristic (ROC) analysis, using multiple anchors. Results Significant correlations were found between outcome measures and anchors. Thresholds were determined for outcome measures coupled with satisfaction, patient-perceived function and a combination thereof using a cut-off of 50 and 70. Conclusions We have established a set of thresholds for Oxford scores that may help determine which THR patients are in need of postoperative evaluation. These thresholds can be implemented in clinical practice. Level of evidence Level 3

    Serum 25-hydroxyvitamin D, calcium and parathyroid hormone levels in Native and European populations in Greenland

    Get PDF
    AbstractCa homoeostasis is important to human health and tightly controlled by powerful hormonal mechanisms that display ethnic variation. Ethnic variations could occur also in Arctic populations where the traditional Inuit diet is low in Ca and sun exposure is limited. We aimed to assess factors important to parathyroid hormone (PTH) and Ca in serum in Arctic populations. We included Inuit and Caucasians aged 50–69 years living in the capital city in West or in rural East Greenland. Lifestyle factors were assessed by questionnaires. The intake of Inuit diet was assessed from a FFQ. 25-Hydroxyvitamin D (25OHD2and 25OHD3) levels were measured in serum as was albumin, Ca and PTH. The participation rate was 95 %, with 101 Caucasians and 434 Inuit. Median serum 25OHD (99·7 % was 25OHD3) in Caucasians/Inuit was 42/64 nmol/l (25, 75 percentiles 25, 54/51, 81) (P&lt;0·001). Total Ca in serum was 2·33/2·29 mmol/l (25, 75 percentiles 2·26, 2·38/2·21, 2·36) (P=0·01) and PTH was 2·7/2·2 pmol/l (25, 75 percentiles 2·2, 4·1/1·7, 2·7) (P&lt;0·001). The 69/97 Caucasians/Inuit with serum 25OHD &lt;50 nmol/l differed in PTH (P=0·001) that rose with lower 25OHD levels in Caucasians, whereas this was not the case in Inuit. Ethnic origin influenced PTH (β=0·27,P&lt;0·001) and Ca (β=0·22,P&lt;0·001) in multivariate linear regression models after adjustment for age, sex, BMI, smoking, alcohol and diet. In conclusion, ethnic origin influenced PTH, PTH response to low vitamin D levels and Ca levels in populations in Greenland. Recommendations are to evaluate mechanisms underlying the ethnic influence on Ca homoeostasis and to assess the impact of transition in dietary habits on Ca homoeostasis and skeletal health in Arctic populations.</jats:p

    No superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups:An 8-year follow-up of 81 patients from a previously reported controlled trial

    No full text
    BACKGROUND AND PURPOSE: Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA- and porous-coated acetabular cups in a prospective randomized trial. METHODS: This was an 8-year follow-up study of our previously published prospective randomized study to compare clinical outcomes, survival, periprosthetic bone mineral density, migration, and wear rates of HA- and porous-coated acetabular cups. Dual X-ray absorptiometry (DXA) and Ein Bild Roentgen Analyse (EBRA) measurements were used. 100 patients who underwent unilateral cementless total hip arthroplasty were randomized to either porous-coated cups or HA-coated cups. Patients were examined preoperatively and at 3, 6, and 9 months, and also 1, 3, and 8 years after surgery. 81 patients were available for 8-year follow-up, 40 with porous-coated cups and 41 with HA-coated cups. RESULTS: Age, sex, bone mineral density, and clinical results (Harris hip score) were similar in the 2 groups. The survival, wear, and migration patterns of the cups were also similar in both groups. The results of periprosthetic bone mineral density scans in region of interest 2 was in favor of the porous-coated cups, but there were no differences between the 2 groups in all the remaining regions of interest. INTERPRETATION: HA coating had no statistically significant effect on clinical results, survival, wear, or migration at the 8-year follow-up

    Bone remodelling of the proximal femur after total hip arthroplasty with 2 different hip implant designs:15 years follow-up of the thrust plate prosthesis and the Bi-Metric stem

    No full text
    Introduction:The thrust plate prosthesis (TPP) was introduced to preserve bone in patients undergoing total hip arthroplasty. We assessed the long-term results of hip arthroplasty in patients who received the TPP compared to a traditional intramedullary stem (Bi-Metric).Methods:In this prospective observational cohort study, we evaluated bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA), radiological imaging and clinical outcome using Harris Hip Score (HHS). Twenty patients received the TPP (group A) and 18 patients received the Bi-Metric stem (group B). Baseline was the 1st postoperative day, and subsequent follow-up was performed at 6 months, 1, 2, 8, 12 and 15 years after surgery. A four regions of interest (ROI) protocol was developed to assess BMD.Results:In ROI1, bone resorption was significantly higher for group A at 6 months with a mean difference of 10% (95% confidence interval [CI], 4–16; p = 0.003) and 8% (95% CI, 1–15; p = 0.03) at 8 years. Regarding ROI4, group A had a lesser decrease in general compared to group B. The radiological findings did not reveal any subsidence or detectable implant migration. HHS improved from 53 (23–69) to 93 (55–100) in group A and from 51 (24–72) to 94 (78–100) in group B.Conclusion:The TPP was not found to be inferior to the Bi-Metric stem regarding bone preservation. The decrease in BMD in ROI4 was greater in group B. Clinical and radiological results also revealed that the TPP was not inferior to the Bi-Metric stem.</jats:sec
    corecore