211 research outputs found

    Optimization by Smoothed Bandpass Calibration in Radio Spectroscopy

    Full text link
    We have developed the Smoothed Bandpass Calibration (SBC) method and the best suitable scan pattern to optimize radio spectroscopic observations. Adequate spectral smoothing is applied to the spectrum toward OFF-source blank sky adjacent to a target source direction for the purpose of bandpass correction. Because the smoothing process reduces noise, the integration time for OFF-source scans can be reduced keeping the signal-to-noise ratio. Since the smoothing is not applied to ON-source scans, the spectral resolution for line features is kept. An optimal smoothing window is determined by bandpass flatness evaluated by Spectral Allan Variance (SAV). An efficient scan pattern is designed to the OFF-source scans within the bandpass stability timescale estimated by Time-based Allan Variance (TAV). We have tested the SBC using the digital spectrometer, VESPA, on the VERA Iriki station. For the targeted noise level of 5e-4 as a ratio to the system noise, the optimal smoothing window was 32 - 60 ch in the whole bandwidth of 1024 ch, and the optimal scan pattern was designed as a sequence of 70-s ON + 10-s OFF scan pairs. The noise level with the SBC was reduced by a factor of 1.74 compared with the conventional method. The total telescope time to achieve the goal with the SBC was 400 s, which was 1/3 of 1200 s required by the conventional way. Improvement in telescope time efficiency with the SBC was calculated as 3x, 2x and 1.3x for single-beam, dual-beam, and on-the-fly (OTF) scans, respectively. The SBC works to optimize scan patterns for observations from now, and also works to improve signal-to-noise ratios of archival data if ON- and OFF-source spectra are individually recorded, though the efficiency depends on the spectral stability of the receiving system.Comment: 12 pages, 11 figures, to appear in the Publications of Astronomical Society of Japan, Vol.64, No.

    Scaling of the Anomalous Boost in Relativistic Jet Boundary Layer

    Full text link
    We investigate the one-dimensional interaction of a relativistic jet and an external medium. Relativistic magnetohydrodynamic simulations show an anomalous boost of the jet fluid in the boundary layer, as previously reported. We describe the boost mechanism using an ideal relativistic fluid and magnetohydrodynamic theory. The kinetic model is also examined for further understanding. Simple scaling laws for the maximum Lorentz factor are derived, and verified by the simulations.Comment: typos corrected; fortran 77/90 codes are attached; see ancillary files in the "Other formats" lin

    Disinfection of otorhinolaryngological endoscopes with electrolyzed acid water: A cross-sectional and multicenter study

    Get PDF
    Glutaraldehyde, a germicide for reprocessing endoscopes that is important for hygiene in the clinic, might be hazardous to humans. Electrolyzed acid water (EAW) has a broad anti-microbial spectrum and safety profile and might be a glutaraldehyde alternative. We sought to assess EAW disinfection of flexible endoscopes in clinical otorhinolaryngological settings and its in vitro inactivation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and bacteria commonly isolated in otorhinolaryngology. Ninety endoscopes were tested for bacterial contamination before and after endoscope disinfection with EAW. The species and strains of bacteria were studied. The in vitro inactivation of bacteria and SARS-CoV-2 by EAW was investigated to determine the efficacy of endoscope disinfection. More than 20 colony-forming units of bacteria at one or more sampling sites were detected in 75/90 microbiological cultures of samples from clinically used endoscopes (83.3%). The most common genus detected was Staphylococcus followed by Cutibacterium and Corynebacterium at all sites including the ears, noses, and throats. In the in vitro study, more than 107 CFU/mL of all bacterial species examined were reduced to below the detection limit ( 105 PFU) was decreased to less than 5 PFU. Effective inactivation of SARS-CoV-2 was also observed with a 19:1 ratio of EAW to the virus. EAW effectively reprocessed flexible endoscopes contributing to infection control in medical institutions in the era of the coronavirus disease 2019 pandemic
    corecore