1 research outputs found
Supplementary Material for: Kidney Volume Estimations with Ellipsoid Equations by Magnetic Resonance Imaging in Autosomal Dominant Polycystic Kidney Disease
<b><i>Background:</i></b> Kidney volume (KV) becomes clinically relevant in autosomal dominant polycystic kidney disease (ADPKD) management. KV can be conveniently estimated (ceKV) using ellipsoid volume equations with three axes measurements; however, the accuracy and reliability are unknown. <b><i>Methods:</i></b> KVs of 347 kidneys in 177 consecutive ADPKD patients were determined with a volumetric method (standard-KV), and ceKV was calculated using six different ellipsoid equations with three axes measurements using magnetic resonance imaging. The inter- and intraobserver reliabilities were analyzed using intraclass correlation coefficients (ICCs). Ellipsoid-KVs were obtained by linear regression analysis between standard-KV and ceKVs, and six ellipsoid-KVs were validated with a bootstrap model. <b><i>Results:</i></b> The ICCs of intra- and interobserver reliabilities in standard-KV and axes measurements were highly reliable. All ceKVs underestimated standard-KV and % differences between ceKV and standard-KV were reduced by ellipsoid-KVs. Bootstrap analyses suggested that six ellipsoid-KVs reliably simulated standard-KV. <b><i>Conclusion:</i></b> Among six ellipsoid-KVs, ellipsoid-KV<sub>3</sub> = 84 + 1.01 x π/24 × Length × (sum of two width measurements)<sup>2</sup> relatively accurately simulated the standard-KV. Kidney volume estimation using ellipsoid equations is reliably applied to clinical management of ADPKD while recognizing wide scattering in the difference between estimated and volumetrically measured kidney volume