22 research outputs found

    Endobronchial Electrocautery Using Snare

    Get PDF
    Between May 1987 and March 1994, upper airway and tracheobronchial electrosurgery with snare was performed in 13 patients (10 men and 3 women), ranging in age from 18 to 87 years. Four patients had benign lesions, and nine had malignant tumors. Total eradication has been achieved in the two patients with benign lesions. Electroexcision of the endobronchial portion of the tumor helped to clear the respiratory airways in all cases with malignant tumors. There has been no major side effects such as bleeding due to this method. Electrocautery is an available economical tool, which helps to diagnose and treat obstructing airway mass lesions

    Clinical Study in 11 Cases of Endobronchial Foreign Body

    Get PDF
    We report 11 cases of endobronchial foreign body. From January 1982 through December 1994, a total of 11 cases were diagnosed roentogenographically and bronchoscopically at our hospital. These patients consisted of 10 men and 1 woman with a mean age of 58.5 years (range 33 to 77 years). Symptoms on presenting were usually cough, sputum, or chest pain. The foreign bodies were inorganic in 10 cases and of organic origin in 1 case. Three patients were not aware that they had aspirated a foreign body. In 9 patients, the endobronchial foreign bodies were successfully removed endoscopically. One patient spontaneously expectorated the foreign body before bronchoscopy. One patient underwent thoracotomy because the foreign body could not be removed bronchoscopically. There were no severe complications during or after the endoscopic removal of the foreign bodies, but in one patient extraction of the foreign body caused pneumonia after bronchoscopy. In conclusion, flexible bronchoscopy is useful for the diagnosis and treatment of endobronchial foreign bodies

    The Far-Infrared Surveyor (FIS) for AKARI

    Full text link
    The Far-Infrared Surveyor (FIS) is one of two focal plane instruments on the AKARI satellite. FIS has four photometric bands at 65, 90, 140, and 160 um, and uses two kinds of array detectors. The FIS arrays and optics are designed to sweep the sky with high spatial resolution and redundancy. The actual scan width is more than eight arcmin, and the pixel pitch is matches the diffraction limit of the telescope. Derived point spread functions (PSFs) from observations of asteroids are similar to the optical model. Significant excesses, however, are clearly seen around tails of the PSFs, whose contributions are about 30% of the total power. All FIS functions are operating well in orbit, and its performance meets the laboratory characterizations, except for the two longer wavelength bands, which are not performing as well as characterized. Furthermore, the FIS has a spectroscopic capability using a Fourier transform spectrometer (FTS). Because the FTS takes advantage of the optics and detectors of the photometer, it can simultaneously make a spectral map. This paper summarizes the in-flight technical and operational performance of the FIS.Comment: 23 pages, 10 figures, and 2 tables. Accepted for publication in the AKARI special issue of the Publications of the Astronomical Society of Japa

    Ezrin, a membrane cytoskeletal cross-linker, is essential for the regulation of phosphate and calcium homeostasis

    Get PDF
    Ezrin cross-links plasma membrane proteins with the actin cytoskeleton. In the kidney, ezrin mainly localizes at the brush border membrane of proximal tubules with the scaffolding protein, Na+/H+ exchanger regulatory factor (NHERF) 1. NHERF1 interacts with the sodium/phosphate cotransporter, Npt2a. Defects in NHERF1 or Npt2a in mice cause hypophosphatemia. Here we studied the physiological role of ezrin in renal phosphate reabsorption using ezrin knockdown mice (Vil2). These mice exhibit hypophosphatemia, hypocalcemia, and osteomalacia. The reduced plasma phosphate concentrations were ascribed to defects in urinary phosphate reabsorption. Immunofluorescence and immunoblotting indicated a marked reduction in renal Npt2a and NHERF1 expression at the apical membrane of proximal tubules in the knockdown mice. On the other hand, urinary loss of calcium was not found in Vil2 mice. Plasma concentrations of 1,25-dihydroxyvitamin D were elevated following reduced plasma phosphate levels, and mRNA of the vitamin D–dependent TRPV6 calcium channel were significantly increased in the duodenum of knockdown mice. Expression of TRPV6 at the apical membrane, however, was significantly decreased. Furthermore, tibial bone mineral density was significantly lower in both the adult and young Vil2 mice. These results suggest that ezrin is required for the regulation of systemic phosphate and calcium homeostasis in vivo
    corecore