83 research outputs found

    Rotational wind indicator enhances control of rotated displays

    Get PDF
    Rotation by 108 deg of the spatial mapping between a visual display and a manual input device produces large spatial errors in a discrete aiming task. These errors are not easily corrected by voluntary mental effort, but the central nervous system does adapt gradually to the new mapping. Bernotat (1970) showed that adding true hand position to a 90 deg rotated display improved performance of a compensatory tracking task, but tracking error rose again upon removal of the explicit cue. This suggests that the explicit error signal did not induce changes in the neural mapping, but rather allowed the operator to reduce tracking error using a higher mental strategy. In this report, we describe an explicit visual display enhancement applied to a 108 deg rotated discrete aiming task. A 'wind indicator' corresponding to the effect of the mapping rotation is displayed on the operator-controlled cursor. The human operator is instructed to oppose the virtual force represented by the indicator, as one would do if flying an airplane in a crosswind. This enhancement reduces spatial aiming error in the first 10 minutes of practice by an average of 70 percent when compared to a no enhancement control condition. Moreover, it produces adaptation aftereffect, which is evidence of learning by neural adaptation rather than by mental strategy. Finally, aiming error does not rise upon removal of the explicit cue

    Twin Families of Bisolitons in Dispersion Managed Systems

    Full text link
    We calculate bisoliton solutions using a slowly varying stroboscopic equation. The system is characterized in terms of a single dimensionless parameter. We find two branches of solutions and describe the structure of the tails for the lower branch solutions.Comment: 3 pages 4 figure

    Channel Selection and Feature Projection for Cognitive Load Estimation Using Ambulatory EEG

    Get PDF
    We present an ambulatory cognitive state classification system to assess the subject's mental load based on EEG measurements. The ambulatory cognitive state estimator is utilized in the context of a real-time augmented cognition (AugCog) system that aims to enhance the cognitive performance of a human user through computer-mediated assistance based on assessments of cognitive states using physiological signals including, but not limited to, EEG. This paper focuses particularly on the offline channel selection and feature projection phases of the design and aims to present mutual-information-based techniques that use a simple sample estimator for this quantity. Analyses conducted on data collected from 3 subjects performing 2 tasks (n-back/Larson) at 2 difficulty levels (low/high) demonstrate that the proposed mutual-information-based dimensionality reduction scheme can achieve up to 94% cognitive load estimation accuracy

    A hybrid generative/discriminative method for EEG evoked potential detection

    Get PDF
    I. INTRODUCTION Generative and discriminative learning approaches are two prevailing and powerful, yet different, paradigms in machine leaning. Generative learning models, such as Bayesian inference [1] attempt to model the underlying distributions of the variables in order to compute classification and regression functions. These methods provide a rich framework for learning from prior knowledge. Discriminative learning models, such as support vector machines (SVM) [2] avoid generative modeling by directly optimizing a mapping from the inputs to the desired outputs by adjusting the resulting classification boundary. These latter methods commonly demonstrate superior performance in classification. Recently, researchers have investigated the relationship between these two learning paradigms and have attempted to combine their complementary strength

    Blinding efficacy and adverse events following repeated transcranial alternating current, direct current, and random noise stimulation.

    Get PDF
    As transcranial electrical stimulation (tES) protocols advance, assumptions underlying the technique need to be retested to ensure they still hold. Whilst the safety of stimulation has been demonstrated mainly for a small number of sessions, and small sample size, adverse events (AEs) following multiple sessions remain largely untested. Similarly, whilst blinding procedures are typically assumed to be effective, the effect of multiple stimulation sessions on the efficacy of blinding procedures also remains under question. This is especially relevant in multisite projects where small unintentional variations in protocol could lead to inter-site difference. We report AE and blinding data from 1,019 participants who received up to 11 semi-consecutive sessions of active or sham transcranial alternating current stimulation (tACS), direct current stimulation (tDCS), and random noise stimulation (tRNS), at 4 sites in the UK and US. We found that AEs were often best predicted by factors other than tES, such as testing site or session number. Results from the blinding analysis suggested that blinding was less effective for tDCS and tACS than tRNS. The occurrence of AEs did not appear to be linked to tES despite the use of smaller electrodes or repeated delivery. However, blinding efficacy was impacted in tES conditions with higher cutaneous sensation, highlighting a need for alternative stimulation blinding protocols. This may be increasingly necessary in studies wishing to deliver stimulation with higher intensities
    corecore