7 research outputs found

    Correlation of serum lipid profile and glycemic control parameters in patients with type 2 diabetes mellitus

    Get PDF
    Introduction: Diabetes mellitus type 2 has become a global health-care problem of modern society due to a pronounced increase of prevalence to pandemic proportions and vascular complications. At present, glycated hemoglobin (HbA1c) is widely accepted as a measure of glycemic control in established diabetes. The aim of this study was to analyze the lipid profile in serum of patients with diabetes mellitus type 2, and its relationship with HbA1c levels. Methods: The observational cross-sectional study included 60 diabetic patients, 30 men, and 30 women, age 32ā€“94 years. Patients were assigned into two groups based on HbA1c values; Group 1: HbA1c ā‰¤ 7% (good glycemic control) and Group 2: HbA1c > 7% (poor glycemic control). We analyzed the concentration of glucose, HbA1c, and lipid profile including total cholesterol levels, triglycerides (TAG), low-density lipoproteins (LDL), and high-density lipoproteins (HDL). Results: Significantly lower values of glucose concentration, TAG and the ratio TAG/HDLc were obtained in the group of patients with good glycemic control. (p 0.005) Our study revealed a significant positive correlation between HbA1c and triglyceride level (r = 0.375; p = 0.003) and HbA1c and ratio triglyceride/HDLc (r = 0.335; p = 0.009). Conclusion: HbA1c can also be used as a predictor of dyslipidemia in type 2 diabetics in addition to as a glycemic control parameter

    Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Get PDF
    Introduction: Glycated hemoglobin (HbA1c) is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the Ɵ-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems.Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens) and Cobas 501 (Roche) analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad) at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99.Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision

    Risk assessment in biomedical laboratories ā€“ occupational safety and health aspects

    Get PDF
    Introduction: Laboratory personnel (LP) represent a high-risk group of healthcare workers for whom the primary laboratory environment and specific work activities are a major source of potential exposure to health hazards. This study aimed to evaluate the developed matrix and assess risk based on self-assessment. Methods: This multicenter, qualitative, and cross-sectional study was conducted on LP employed in biomedical laboratories. The respondents were divided into groups according to their territorial affiliation. The data collection tool used was a six-area questionnaire distributed online through a network of professional associations. For the risk assessment, a matrix was developed with scores ranging from 0 to 650, dividing the risk level into four categories. Descriptive and inferential statistical methods were used for the statistical analysis. Results: The developed model combined the classification of risk and risk factors with a certainty of p < 0.001. The regression analysis showed that working conditions had the greatest influence on overall risk, followed by physical, biological, and chemical hazards. Of the 640 respondents, the medium risk category was the highest in European Union (EU) countries (81.2%). Comparing the values in the high-risk category between the Bosnians and Herzegovinians (BiH) group and the Republic of Serbia, Republic of Northern Macedonia, and Montenegro (SCM) group with the EU group, a doubling (16.6%: 36.7%) and tripling (16.6%: 52.1%) of the proportion was found, respectively (p < 0.001). Overall, 1.7% of the LPs from BiH fell into the high-risk category. Conclusions: The designed matrix provides a reliable basis for identifying risk predictors in the study population and can serve as a useful tool for conducting risk assessments in biomedical laboratories. The results of the risk assessment indicate significant differences between the studied groups and highlight the need for increased control of BiH workplaces through new regulatory requirements

    Evaluation of high sensitivity C-reactive protein assay in cerebrospinal fluid on the Dimension RxL analyzer

    Get PDF
    <strong>Introduction</strong>: Low sensitivity and specificity in traditional laboratory tests became insufficient for accurate diagnostics and initiation of proper treatment of patients infected with bacterial meningitis. High sensitivity C reactive protein (hsCRP) may be an appropriate supplement for rapid diagnosis of bacterial meningitis. The subject of our investigation was the determination of C- reactive protein in cerebrospinal fluid (CSF) during<br />acute bacterial meningitis.<br /><strong>Methods:</strong> HsCRP was analysed by a sensitive immunoturbidimetric assay using the Dimension RxL analyser (Siemens). Cerebrospinal fluid concentrations of C-reactive protein have been measured in 20 patients<br />(age range,1 to 50 years) presenting with acute bacterial meningitis and also in a non-infected, non-inflamed control group (n=25).<br /><strong>Results:</strong> The accuracy and precision of the method proved to be satisfactory. Repeatability of serial sampling for hsCRP described by coefficient of variation were CV=2.1-4.5%. This assay hsCRP in cerebrospinal fluid demonstrates adequate performance characteristics for routine clinical use. Elevated levels of CRP were found in 95% patients with bacterial meningitis. The mean CRP value in 25 uninfected control group was 0.25 mg/L (range 0.10-0.55). The mean CRP for patients with bacterial meningitis was 21.4 mg/L (range 0.40-100).<br /><strong>Conclusions:</strong> A sensitive assay for CRP in CSF would be an useful adjunct to conventional investigation of acute infective meningitis

    Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Get PDF
    Introduction: Glycated hemoglobin (HbA1c) is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the Ɵ-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems. Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens) and Cobas 501 (Roche) analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad) at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99. Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision

    Clinical aspects and importance of nutrition in homeostasis of the bone tissue

    Get PDF
    Substantial changes have occurred in the nutritional management of many diseases in the last twenty years. Introduction of standards, clinical review and implementation of evidence based practice led to re-evaluation of some established dietary interventions. The most common form of osteoporosis is the primary osteoporosis, which is the result of the bone loss and deterioration of bone structure, as people age. Bone loss and osteoporosis can be prevented through adequate nutrition, physical activity, and, if necessary, appropriate treatment. This review will focus on nutritional and clinical aspects of bone tissue homeostasis, with references to physiological and pathophysiological processes.Ā 